J Card Surg ; 33(10): 693-702, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30199919

ABSTRACT

BACKGROUND: The associations between mechanical circulatory support (MCS), acquired von Willebrand syndrome (AvWS), and clinical outcome are incompletely understood. METHODS: In 128 heart failure patients with pulsatile MCS implants (65 total artificial heart or biventricular assist device implants, 63 left ventricular assist device [LVAD] implants) and 76 patients with continuous flow LVAD implants, we analyzed the von Willebrand factor (vWF) profile before (≤24 h) and 17.5 (standard deviation: 5.1) days after device implant. We determined vWF concentrations, vWF activity, and vWF collagen binding capacity and calculated ratios of vWF activity/binding capacity with vWF concentration. The relation of the vWF profile with clinical outcomes such as stroke, gastrointestinal bleeding, and survival was also evaluated. Events were assessed up to 1 year of device implant. RESULTS: All entities of vWF were already significantly elevated preoperatively and remained high after MCS implantation. The ratios of vWF activity/concentration (vWF:RCo/Ag) and collagen binding capacity/concentration (vWF:CBA/Ag) were significantly reduced preoperatively and remained low postoperatively, indicating AvWS. The preoperative alterations in the vWF profile were already present in patients without intra-aortic balloon pump and/or extracorporeal circulatory membrane oxygenation implants. The vWF profile was unrelated to postoperative stroke. However, a higher postoperative ratio of vWF:CBA/Ag was independently associated with increased gastrointestinal bleeding. In addition, a postoperative increase in vWF concentrations and activity were independent predictors of increased 1-year mortality. CONCLUSIONS: Our data indicate that AvWS is present in heart failure patients before device implantation, and is independently associated with clinical outcomes, especially with 1-year mortality.


Subject(s)
Heart Failure/therapy , Heart-Assist Devices , von Willebrand Factor/metabolism , Aged , Cohort Studies , Collagen/metabolism , Female , Gastrointestinal Hemorrhage , Heart Failure/mortality , Humans , Male , Middle Aged , Predictive Value of Tests , Protein Binding , Stroke , Survival Rate , Time Factors , Treatment Outcome
2.
PLoS One ; 12(1): e0169896, 2017.
Article in English | MEDLINE | ID: mdl-28095452

ABSTRACT

BACKGROUND: In terminal failing hearts ventricular assist devices (VAD) are implanted as a bridge to transplantation. Endothelin receptor (ETR) antagonists are used for treatment of secondary pulmonary hypertension in VAD patients. However, the cardiac ETR regulation in human heart failure and during VAD support is incompletely understood. METHODS: In paired left ventricular samples of 12 dilated cardiomyopathy patients we investigated the density of endothelin A (ETA) and B (ETB) receptors before VAD implantation and after device removal. Left ventricular samples of 12 non-failing donor hearts served as control. Receptor quantification was performed by binding of [125I]-ET-1 in the presence of nonselective and ETA selective ETR ligands as competitors. Additionally, the ETR mRNA expression was analyzed using quantitative real-time-PCR. RESULTS: The mRNA of ETA but not ETB receptors was significantly elevated in heart failure, whereas total ETR density analyzed by radioligand binding was significantly reduced due to ETB receptor down regulation. ETA and ETB receptor density showed poor correlation to mRNA data (spearman correlation factor: 0.43 and 0.31, respectively). VAD support had no significant impact on the density of both receptors and on mRNA expression of ETA whereas ETB mRNA increased during VAD. A meta-analysis reveals that the ETA receptor regulation in human heart failure appears to depend on non-failing hearts. CONCLUSIONS: In deteriorating hearts of patients suffering from dilated cardiomyopathy the ETA receptor density is not changed whereas the ETB receptor is down regulated. The mRNA and the proteins of ETA and ETB show a weak correlation. Non-failing hearts might influence the interpretation of ETA receptor regulation. Mechanical unloading of the failing hearts has no impact on the myocardial ETR density.


Subject(s)
Cardiomyopathy, Dilated/metabolism , Cardiomyopathy, Dilated/surgery , Heart Ventricles/metabolism , Heart-Assist Devices , Myocardium/metabolism , Receptor, Endothelin A/metabolism , Receptor, Endothelin B/metabolism , Blotting, Western , Case-Control Studies , Humans , Immunoenzyme Techniques , RNA, Messenger/genetics , Real-Time Polymerase Chain Reaction , Receptor, Endothelin A/genetics , Receptor, Endothelin B/genetics , Reverse Transcriptase Polymerase Chain Reaction , Ventricular Function, Left/physiology