1.
Heliyon ; 10(3): e25513, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38352734

ABSTRACT

In this work, thermodynamic calculations for α + ß Type Ti-Fe-Cu-Sn alloy were carried out by the Thermo-Calc software. Powders from this alloy were obtained by plasma sputtering and used for subsequent 3D printing of experimental samples. The effect of various selective laser melting (SLM) parameters on porosity and hot cracking susceptibility as well as the electrochemical characteristics of the alloy have been studied. The optimal technological regime for the manufacture of samples by the SLM method was determined. It has been established that to obtain relatively dense samples without cracks, regimes with volumetric energy density Ev = 250-300 J/mm3 are required. It has been established that a change in the electrochemical behavior of the Ti94Fe1Cu1Sn4 alloy is related to the formation of a nonequilibrium Ti2Cu phase. Based on the findings we recomended directions for further research.

2.
Sci Rep ; 12(1): 3023, 2022 02 22.
Article in English | MEDLINE | ID: mdl-35194138

ABSTRACT

A linear combination of spherically symmetric heat sources is shown to provide optimal stationary thermal distribution in magnetic hyperthermia. Furthermore, such spatial location of heat sources produces suitable temperature distribution in biological medium even for assemblies of magnetic nanoparticles with a moderate value of specific absorption rate (SAR), of the order of 100-150 W/g. We also demonstrate the advantage of using assemblies of spherical magnetic nanocapsules consisting of metallic iron nanoparticles covered with non magnetic shells of sufficient thickness in magnetic hyperthermia. Based on numerical simulation we optimize the size and geometric structure of biocompatible spherical capsules in order to minimize the influence of strong magneto-dipole interaction between closely spaced nanoparticles. It is shown that assembly of capsules can provide sufficiently high SAR values of the order of 250-400 W/g at moderate amplitudes H0 = 50-100 Oe and frequencies f = 100-200 kHz of alternating magnetic field, being appropriate for application in clinics.

3.
Sci Rep ; 11(1): 6999, 2021 Mar 26.
Article in English | MEDLINE | ID: mdl-33772074

ABSTRACT

Detailed calculations of the specific absorption rate (SAR) of a dilute assembly of iron oxide nanoparticles with effective uniaxial anisotropy dispersed in a liquid are performed depending on the particle diameters, the alternating (ac) magnetic field amplitude H0 and the liquid viscosity. For small and moderate H0 values with respect to particle anisotropy field Hk the SAR of the assembly as a function of the particle diameter passes through a characteristic maximum and then reaches a plateau, whereas for sufficiently large amplitudes, H0 ~ Hk, the SAR increases monotonically as a function of diameter. The realization of viscous and magnetic oscillation modes for particle unit magnetization vector and director for moderate and sufficiently large H0 values, respectively, explains this behavior. It is found that the SAR of the assembly changes inversely with the viscosity only in a viscous mode, for nanoparticles of sufficiently large diameters. In the magnetic mode the SAR of the assembly is practically independent of the viscosity, since in this case the nanoparticle director only weakly oscillates around the ac magnetic field direction. The conditions for the validity of the linear response theory have been clarified by comparison with the numerical simulation data.