Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Org Lett ; 26(22): 4621-4625, 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38810616

ABSTRACT

The 1,5-copper-catalyzed carboamination of vinylcyclopropanes is presented. A carbon-centered radical, formed upon reduction of an alkyl halide by Cu(I), adds across the alkene of a vinylcyclopropane, triggering ring opening to generate a benzylic radical, which, finally, undergoes copper-mediated amination to afford a homoallylic amine. The reaction occurs with outstanding regio- and good to very good diastereoselectivities. The scope of the reaction is demonstrated with respect to all three components: alkyl halide, vinylcyclopropane, and amine nucleophile. A total of 38 examples are presented with an average yield of 60%.

2.
Biomed Phys Eng Express ; 5(6)2019 Nov 01.
Article in English | MEDLINE | ID: mdl-34170854

ABSTRACT

Purpose: The intent of this work was to evaluate the ability of our 200 kV kilovoltage arc therapy (KVAT) system to treat realistic lung tumors without exceeding dose constraints to organs-at-risk (OAR).Methods and Materials: Monte Carlo (MC) methods and the McO optimization framework generated and inversely optimized KVAT treatment plans for 3 SABR lung cancer patients. The KVAT system was designed to treat deep-seated lesions with kilovoltage photons. KVAT delivers dose to roughly spherical PTVs and therefore non-spherical PTVs were divided into spherical sub-volumes. A prescription dose of 12 Gy/fx × 4 fractions was planned to 90% of the PTV volume. KVAT plans were compared to VMC++ calculated, 6 MV stereotactic ablative radiotherapy (SABR) treatment plans. Dose distributions, dose volume histograms, gradient index (GI), planned mean doses and plan treatment times were calculated. Dose constraints for organs-at-risk (OAR) were taken from RTOG 101.Results: All plans, with the exception of the rib dose calculated in one of the KVAT plans for a peripheral lesion, were within dose-constraints. In general, KVAT plans had higher planned doses to OARs. KVAT GI values were 5.7, 7.2 and 8.9 and SABR values were 4.6, 4.1, and 4.7 for patient 1, 2 and 3, respectively. KVAT plan treatment times were 49, 65 and 17 min for patients 1, 2 and 3, respectively.Conclusions: Inverse optimization and MC methods demonstrated the ability of KVAT to produce treatment plans without exceeding TG 101 dose constraints to OARs for 2 out of 3 investigated lung cancer patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...