Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev Lett ; 127(3): 033902, 2021 Jul 16.
Article in English | MEDLINE | ID: mdl-34328760

ABSTRACT

We present the first observations, and a complete theoretical explanation, of stimulated photorefractive scattering in a high- Q crystalline cavity. The standing-wave light field in the cavity induces an ultranarrow and long-lived Bragg grating through the photorefractive effect. The spatial phase of the grating is automatically matched to that of the standing wave. The scattering from the grating strengthens the standing wave, which then further reinforces the grating itself. Eventually, the mode is seen to split into a doublet, thereby disrupting the usual strict periodicity of the mode spectrum.

2.
Phys Rev Lett ; 112(16): 160801, 2014 Apr 25.
Article in English | MEDLINE | ID: mdl-24815630

ABSTRACT

We demonstrate thermometry with a resolution of 80 nK/Hz using an isotropic crystalline whispering-gallery mode resonator based on a dichroic dual-mode technique. We simultaneously excite two modes that have a mode frequency ratio that is very close to two (±0.3 ppm). The wavelength and temperature dependence of the refractive index means that the frequency difference between these modes is an ultrasensitive proxy of the resonator temperature. This approach to temperature sensing automatically suppresses sensitivity to thermal expansion and vibrationally induced changes of the resonator. We also demonstrate active suppression of temperature fluctuations in the resonator by controlling the intensity of the driving laser. The residual temperature fluctuations are shown to be below the limits set by fundamental thermodynamic fluctuations of the resonator material.

3.
Opt Lett ; 39(6): 1581-4, 2014 Mar 15.
Article in English | MEDLINE | ID: mdl-24690843

ABSTRACT

We investigate the impact of pulse interleaving and optical amplification on the spectral purity of microwave signals generated by photodetecting the pulsed output of an Er:fiber-based optical frequency comb. It is shown that the microwave phase noise floor can be extremely sensitive to delay length errors in the interleaver, and the contribution of the quantum noise from optical amplification to the phase noise can be reduced ∼10 dB for short pulse detection. We exploit optical amplification, in conjunction with high power handling modified unitraveling carrier photodetectors, to generate a phase noise floor on a 10 GHz carrier of -175 dBc/Hz, the lowest ever demonstrated in the photodetection of a mode-locked fiber laser. At all offset frequencies, the photodetected 10 GHz phase noise performance is comparable to or better than the lowest phase noise results yet demonstrated with stabilized Ti:sapphire frequency combs.

4.
Phys Rev Lett ; 108(26): 260801, 2012 Jun 29.
Article in English | MEDLINE | ID: mdl-23004951

ABSTRACT

In this Letter, we present an improved constraint on possible isotropic variations of the speed of light. Within the framework of the standard model extension, we provide a limit on the isotropic, scalar parameter κ̃(tr) of 3±11×10({-10), an improvement by a factor of 6 over previous constraints. This was primarily achieved by modulating the orientation of the experimental apparatus with respect to the velocity of Earth. This orientation modulation shifts the signal for Lorentz invariance to higher frequencies, and we have taken advantage of the higher stability of the resonator at shorter time scales, together with better rejection of systematic effects, to provide a new constraint.

5.
Opt Lett ; 36(24): 4776-8, 2011 Dec 15.
Article in English | MEDLINE | ID: mdl-22179880

ABSTRACT

We have constructed a compact and robust optical frequency standard based around iodine vapor loaded into the core of a hollow-core photonic crystal fiber (HC-PCF). A 532 nm laser was frequency locked to one hyperfine component of the R(56) 32-0 (127)I(2) transition using modulation transfer spectroscopy. The stabilized laser demonstrated a frequency stability of 2.3×10(-12) at 1 s, almost an order of magnitude better than previously reported for a laser stabilized to a gas-filled HC-PCF. This limit is set by the shot noise in the detection system. We present a discussion of the current limitations to the performance and a route to improve the performance by more than an order of magnitude.

SELECTION OF CITATIONS
SEARCH DETAIL
...