Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37702561

ABSTRACT

Novel photocathode materials like ordered surfaces of single crystal metals, epitaxially grown high quantum efficiency thin films, and topologically non-trivial materials with dirac cones show great promise for generating brighter electron beams for various accelerator and ultrafast electron scattering applications. Despite several materials being identified as brighter photocathodes, none of them have been tested in electron guns to extract electron beams due to technical and logistical challenges. In this paper, we present the design and commissioning of a cryocooled 200 kV DC electron gun that is capable of testing a wide variety of novel photocathode materials over a broad range of temperatures from 298 to 35 K for bright electron beam generation. This gun is designed to enable easy transfer of the photocathode to various standard ultra-high-vacuum surface diagnostics and preparation techniques, allowing a full characterization of the dependence of beam brightness on the photocathode material and surface properties. We demonstrate the development of such a high-voltage, high-gradient gun using materials and equipment that are easily available in any standard university lab, making the development of such 200 kV electron guns more accessible.

2.
J Chem Phys ; 153(14): 144705, 2020 Oct 14.
Article in English | MEDLINE | ID: mdl-33086829

ABSTRACT

High-performance photocathodes for many prominent particle accelerator applications, such as x-ray free-electron lasers, cannot be grown in situ. These highly reactive materials must be grown and then transported to the electron gun in an ultrahigh-vacuum (UHV) suitcase, during which time monolayer-level oxidation is unavoidable. Thin film Cs3Sb photocathodes were grown on a variety of substrates. Their performance and chemical state were measured by x-ray photoelectron spectroscopy after transport in a UHV suitcase as well as after O2-induced oxidation. The unusual chemistry of cesium oxides enabled trace amounts of oxygen to drive structural reorganization at the photocathode surface. This reorganization pulled cesium from the bulk photocathode, leading to the development of a structurally complex and O2-exposure-dependent cesium oxide layer. This oxidation-induced phase segregation led to downward band bending of at least 0.36 eV as measured from shifts in the Cs 3d5/2 binding energy. At low O2 exposures, the surface developed a low work function cesium suboxide overlayer that had little effect on quantum efficiency (QE). At somewhat higher O2 exposures, the overlayer transformed to Cs2O; no antimony or antimony oxides were observed in the near-surface region. The development of this overlayer was accompanied by a 1000-fold decrease in QE, which effectively destroyed the photocathode via the formation of a tunnel barrier. The O2 exposures necessary for degradation were quantified. As little as 100 L of O2 irreversibly damaged the photocathode. These observations are discussed in the context of the rich chemistry of alkali oxides, along with potential material strategies for photocathode improvement.

3.
Rev Sci Instrum ; 89(8): 083303, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30184700

ABSTRACT

Linear electron accelerators and their applications such as ultrafast electron diffraction require compact high-brightness electron sources with high voltage and electric field at the photocathode to maximize the electron density and minimize space-charge induced emittance growth. Achieving high brightness from a compact source is a challenging task because it involves an often-conflicting interplay between various requirements imposed by photoemission, acceleration, and beam dynamics. Here we present a new design for a compact high voltage DC electron gun with a novel cryogenic photocathode system and report on its construction and commissioning process. This photoemission gun can operate at ∼200 kV at both room temperature and cryogenic temperature with a corresponding electric field of 10 MV/m, necessary for achieving high quality electron beams without requiring the complexity of guns, e.g., based on RF superconductivity. It hosts a compact photocathode plug compatible with that used in several other laboratories opening the possibility of generating and characterizing electron beam from photocathodes developed at other institutions.

4.
Rev Sci Instrum ; 86(7): 073309, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26233374

ABSTRACT

This paper reports the development of a simple and reliable apparatus for measuring ultra-low emittance, or equivalently the mean transverse energy from cryogenically cooled photocathodes. The existing methods to measure ultra-low emittance from photocathodes are reviewed. Inspired by the available techniques, we have implemented two complementary methods, the waist scan and voltage scan, in one system giving consistent results. Additionally, this system is capable of measuring the emittance at electric fields comparable to those obtained in DC photoinjectors.

5.
Rev Sci Instrum ; 86(3): 033301, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25832217

ABSTRACT

A 2-D electron energy analyzer is designed and constructed to measure the transverse and longitudinal energy distribution of low energy (<1 eV) electrons. The analyzer operates on the principle of adiabatic invariance and motion of low energy electrons in a strong longitudinal magnetic field. The operation of the analyzer is studied in detail and a design to optimize the energy resolution, signal to noise ratio, and physical size is presented. An energy resolution better than 6 meV has been demonstrated. Such an analyzer is a powerful tool to study the process of photoemission which limits the beam quality in modern accelerators.

6.
Rev Sci Instrum ; 85(9): 093306, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25273718

ABSTRACT

A new high voltage photoemission gun has been constructed at Cornell University which features a segmented insulator and a movable anode, allowing the cathode-anode gap to be adjusted. In this work, we describe the gun's overall mechanical and high voltage design, the surface preparation of components, as well as the clean construction methods. We present high voltage conditioning data using a 50 mm cathode-anode gap, in which the conditioning voltage exceeds 500 kV, as well as at smaller gaps. Finally, we present simulated emittance results obtained from a genetic optimization scheme using voltage values based on the conditioning data. These results indicate that for charges up to 100 pC, a 30 mm gap at 400 kV has equal or smaller 100% emittance than a 50 mm gap at 450 kV, and also a smaller core emittance, when placed as the source for the Cornell energy recovery linac photoinjector with bunch length constrained to be <3 ps rms. For 100 pC up to 0.5 nC charges, the 50 mm gap has larger core emittance than the 30 mm gap, but conversely smaller 100% emittance.

7.
Phys Rev Lett ; 112(9): 097601, 2014 Mar 07.
Article in English | MEDLINE | ID: mdl-24655275

ABSTRACT

Crucial photoemission properties of layered III-V semiconductor cathodes are predicted using Monte Carlo simulations. Using this modeling, a layered GaAs structure is designed to reduce simultaneously the transverse energy and response time of the emitted electrons. This structure, grown by molecular beam epitaxy and activated to negative electron affinity, is characterized. The measured values of quantum efficiency and transverse energy are found to agree well with the simulations. Such advanced layered structures will allow generation of short electron bunches from photoinjectors with superior beam brightness.

8.
J Synchrotron Radiat ; 21(Pt 2): 289-99, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24562550

ABSTRACT

In an effort to provide a computationally convenient approach to the characterization of partially coherent synchrotron radiation in phase space, a thorough discussion of the minimum dimensionality of the Wigner distribution function for rotationally symmetric sources of arbitrary degrees of coherence is presented. It is found that perfectly coherent, perfectly incoherent and partially coherent sources may all be characterized by a three-dimensional reduced Wigner distribution function, and some special cases are discussed in which a two-dimensional reduced Wigner distribution function suffices. An application of the dimension-reducing formalism to the case of partially coherent radiation from a planar undulator and a circularly symmetric electron beam as can be found in linear accelerators is demonstrated. The photon distribution is convolved over a realistic electron bunch, and how the beta function, emittance and energy spread of the bunch affect the total degree of coherence of the radiation is inspected. Finally the cross spectral density is diagonalized and the eigenmodes of the partially coherent radiation are recovered.

9.
Opt Express ; 20(5): 4850-5, 2012 Feb 27.
Article in English | MEDLINE | ID: mdl-22418291

ABSTRACT

A fiber amplifier that generates nearly transform-limited sub-picosecond pulses and greater than 100 W average power at 1.3-GHz repetition rate is described. Modest stretching of the seed pulses allows the amplifier to be operated in the linear regime. The amplified and dechirped pulses exhibit excellent beam quality, and can be frequency-doubled to produce green pulses at 65 W average power. Detailed characterization of the performance is presented.


Subject(s)
Amplifiers, Electronic , Fiber Optic Technology/instrumentation , Lasers , Lighting/instrumentation , Color , Energy Transfer , Infrared Rays , Microwaves
10.
Phys Rev Lett ; 102(10): 104801, 2009 Mar 13.
Article in English | MEDLINE | ID: mdl-19392119

ABSTRACT

Electron injectors delivering relativistic electron beams with very high brightness are essential for a number of current and proposed electron accelerator applications. These high brightness beams are generally produced from photoemission cathodes. We formulate a limit on the electron beam brightness from such cathodes set by the transverse thermal energy of the electrons leaving the photocathode and the accelerating field at the cathode. Two specific examples--direct measurement of the transverse phase space of a space charge dominated beam from a high-voltage photoemission electron gun and a numerical optimization of the same at a higher gun voltage--illustrate the importance of this limit.

11.
Appl Opt ; 46(35): 8488-92, 2007 Dec 10.
Article in English | MEDLINE | ID: mdl-18071380

ABSTRACT

We report on a simple and robust technique to temporally shape ultrashort pulses. A number of birefringent crystals with appropriate crystal length and orientation form a crystal set. When a short pulse propagates through the crystal set, the pulse is divided into numerous pulses, producing a desired temporal shape. Flexibility in the final pulse shape is achieved through varying initial pulse duration, divided-pulse number, the polarization-mode delay, and energy distribution of the divided pulses. The energy efficiency of the technique is near 100% for a pulse train of alternating polarizations, and 50% for a linearly polarized pulse train.

12.
J Synchrotron Radiat ; 11(Pt 5): 432-8, 2004 Sep 01.
Article in English | MEDLINE | ID: mdl-15310961

ABSTRACT

Coherent diffractive imaging using a coherent X-ray source promises to be a useful microscopic method for imaging noncrystalline objects at high spatial resolution. In this article a simple method to estimate the coherently scattered signal as a function of resolution is presented, and it is shown that the required X-ray flux or dose scales as the inverse third power of resolution for a specimen of constant volume and density. A simulated case study using the proposed energy-recovery linac source is also presented, which confirms the estimated flux requirement.

SELECTION OF CITATIONS
SEARCH DETAIL
...