Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Vet Comp Orthop Traumatol ; 33(1): 59-65, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31756751

ABSTRACT

OBJECTIVE: The aim of this study was to report efficacy of a modified tibial plateau levelling osteotomy (TPLO) with double cut and medial crescentic closing wedge osteotomy (TPLO/MCCWO) to treat dogs with cranial cruciate ligament rupture and concurrent tibial valgus. STUDY DESIGN: This study was a cases series. MATERIALS AND METHODS: Medical records of dogs that had TPLO with medial crescentic closing wedge osteotomy were reviewed. Data collected included signalment, body weight, pre- and postoperative tibial valgus angle, tibial plateau angle (TPA), surgical planning, corrective osteotomy technique, method of fixation, complications, and length of time to radiographic healing. RESULTS: Fifty-two surgical procedures performed in 45 dogs (7 bilateral) were included in the study. Mean age at surgery was 54 months, and body weight ranged from 5 to 63 kg (mean: 36.5 kg). Mean pre- and postoperative mechanical medial proximal tibial angle were 101° (98°-107°) and 92.80° (88°-97°) respectively. The mean pre- and postoperative TPA were 27.80° (16-35°) and 6.50° (3-11°) respectively. Intraoperative complications occurred in two stifles: in one stifle over-rotation of the proximal tibial segment resulted in a TPA of -8°, with immediate revision to a 5° TPA; in the second stifle a fissure of the lateral tibial cortex developed during insertion of a screw and required adjunctive fixation. No postoperative complications were recorded and all osteotomies healed uneventfully. CONCLUSIONS: Tibial plateau levelling osteotomy/medial crescentic closing wedge osteotomy is an effective treatment for dogs with cranial cruciate ligament rupture and tibial valgus allowing accurate correction of the tibial deformity with a low complication rate.


Subject(s)
Anterior Cruciate Ligament/pathology , Dog Diseases/surgery , Osteotomy/veterinary , Rupture/veterinary , Tibia/abnormalities , Animals , Anterior Cruciate Ligament/surgery , Dogs , Osteotomy/methods , Retrospective Studies , Rupture/surgery , Tibia/surgery
2.
Vet Comp Orthop Traumatol ; 30(1): 81-87, 2017 Jan 16.
Article in English | MEDLINE | ID: mdl-27849107

ABSTRACT

OBJECTIVE: To report revision of BFX cementless press-fit stem loosening with a Kyon cementless stem and a head adaptor in two dogs. METHODS: Total hip arthroplasty stem revision was performed in two dogs with loosening of a previously implanted Biomedtrix press-fit BFX stem. Both dogs had a well-integrated BFX cup and single stage revision was performed using a standard Kyon stem and a head adaptor in order to couple with a 17 mm head and maintain the BFX cup. RESULTS: Revisions resulted in a stable functional prosthesis with successful bone integration at the one-year postoperative re-evaluation. CONCLUSIONS: Use of a Kyon stem with a head adaptor may be a successful option to provide immediate stem stability for revision of a loosened BFX stem with a properly osseointegrated cup.


Subject(s)
Arthroplasty, Replacement, Hip/veterinary , Dog Diseases/surgery , Hip Prosthesis/veterinary , Animals , Arthroplasty, Replacement, Hip/instrumentation , Bone Cements , Dogs , Equipment Design/veterinary , Female , Lameness, Animal/surgery , Prosthesis Failure , Reoperation/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL
...