Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Spine J ; 21(12): 2097-2103, 2021 12.
Article in English | MEDLINE | ID: mdl-34029756

ABSTRACT

BACKGROUND CONTEXT: Osseointegration is a pivotal process in achieving a rigid fusion and ultimately a successful clinical outcome following interbody fusion surgery. Advancements in 3D printing technology permit commonly used titanium interbody spacers to be designed with unique architectures, such as a highly interconnected and specific porous structure that mimics the architecture of trabecular bone. Interbody implants with a microscale surface roughness and biomimetic porosity may improve bony ongrowth and ingrowth compared to traditional materials. PURPOSE: The purpose of this study was to compare the osseointegration of lumbar interbody fusion devices composed of surgical-grade polyetheretherketone (PEEK), titanium-alloy (TAV), and 3D-printed porous, biomimetic TAV (3DP) using an in vivo ovine model. STUDY DESIGN: In Vivo Preclinical Animal Study METHODS: Eighteen sheep underwent two-level lateral lumbar interbody fusion randomized with either 3DP, PEEK, or TAV interbody spacers (n=6 levels for each spacer per time point). Postoperative time points were 6 and 12 weeks. Microcomputed tomography and histomorphometry were used to quantify bone volume (BV) within the spacers (ingrowth) and the surface bone apposition ratio (BAR) (ongrowth), respectively. RESULTS: The 3DP-treatment group demonstrated significantly higher BV than the PEEK and TAV groups at 6 weeks (77.3±44.1 mm3, 116.9±43.0 mm3, and 108.7±15.2 mm3, respectively) (p<.05). At 12 weeks, there were no BV differences between groups (p>.05). BV increased in all groups from the 6- to 12-week time points (p<.05). At both time points, the 3DP-treated group (6w: 23.6±10.9%; 12w: 36.5±10.9%) had significantly greater BAR than the PEEK (6w: 8.6±2.1%; 12w: 14.0±5.0%) and TAV (6w: 6.0±5.7%; 12w: 4.1±3.3%) groups (p<.05). CONCLUSIONS: 3DP interbody spacers facilitated greater total bony ingrowth at 6 weeks, and greater bony ongrowth postoperatively at both 6 and 12 weeks, in comparison to solid PEEK and TAV implants. CLINICAL SIGNIFICANCE: Based on these findings, the 3DP spacers may be a reasonable alternative to traditional PEEK and TAV spacers in various clinical applications of interbody fusion.


Subject(s)
Spinal Fusion , Titanium , Alloys , Animals , Benzophenones , Ketones , Polyethylene Glycols , Polymers , Printing, Three-Dimensional , Sheep , X-Ray Microtomography
2.
Nanomedicine ; 14(7): 2495-2503, 2018 10.
Article in English | MEDLINE | ID: mdl-28571834

ABSTRACT

Magnesium's complete in vivo degradation is appealing for medical implant applications. Rapid corrosion and hydrogen bubble generation along with inflammatory host tissue response have limited its clinical use. Here we electropolymerized a poly (3,4-ethylenedioxythiophene) (PEDOT) and graphene oxide (GO) film directly on Mg surface. GO acted as nano-drug carrier to carry anti-inflammatory drug dexamethasone (Dex). PEDOT/GO/Dex coatings improved Mg corrosion resistance and decreased the rate of hydrogen production. Dex could be released driven by the electrical current generated from Mg corrosion. The anti-inflammatory activity of the released Dex was confirmed in microglia cultures. This PEDOT/GO/Dex film displayed the ability to both control Mg corrosion and act as an on demand release coating that delivers Dex at the corrosion site to minimize detrimental effects of corrosion byproducts. Such multi-functional smart coating will improve the clinical use of Mg implants. Furthermore, the PEDOT/GO/Drug/Mg system may be developed into self-powered implantable drug delivery devices.


Subject(s)
Coated Materials, Biocompatible/chemistry , Dexamethasone/pharmacology , Drug Liberation , Graphite/chemistry , Magnesium/chemistry , Microglia/drug effects , Polymers/chemistry , Absorbable Implants , Animals , Anti-Inflammatory Agents/chemistry , Anti-Inflammatory Agents/pharmacology , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Cells, Cultured , Corrosion , Delayed-Action Preparations , Dexamethasone/chemistry , Microglia/metabolism , Rats , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...