Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Transfusion ; 53(3): 505-17, 2013 Mar.
Article in English | MEDLINE | ID: mdl-22823283

ABSTRACT

BACKGROUND: Emergency whole blood transfusion is a lifesaving procedure employed on modern battlefields. Rapid device tests (RDTs) are frequently used to mitigate transfusion-transmitted infection risks. STUDY DESIGN AND METHODS: A limited evaluation of the RDT formerly used on battlefields was performed using 50 donor plasma samples and commercially available panels. Five hepatitis C virus (HCV) RDTs with sufficient stated sensitivity and thermostability were assessed using 335 HCV-positive and 339 HCV-negative donor plasma samples, 54 seroconversion panel plasma samples, and 84 HCV-positive and 84 HCV-negative spiked whole blood under normal, hot, and cold storage conditions and normal and hot test conditions, plus an ease-of-use survey. RESULTS: BioRapid HCV test sensitivity on donor plasma was 84% (95% confidence interval [CI], 70.9%-92.8%). Using all positive plasma samples, OraQuick HCV sensitivity exceeded all comparators (99.4%, 95% CI, 98.0%-99.9%, p<0.05). Specificity was consistently high, led by OraQuick HCV at 99.7% (95% CI, 98.6%-100%), statistically superior only to Axiom HCV (p<0.05). Using seroconversion panels, only OraQuick HCV showed equivalent or earlier HCV detection compared to the gold standard. Using spiked whole blood, specificity was consistently high, and sensitivity ranged significantly from 34.5% (95% CI, 25.0%-45.1%) for CORE HCV to 98.8% (95% CI, 94.3%-99.9%) for OraQuick HCV. All comparator RDTs were significantly less sensitive than OraQuick HCV at one or more stress condition. CONCLUSION: This HCV RDT comparison identified significant sensitivity differences, particularly using whole blood under extreme storage and testing conditions. These data support OraQuick HCV superiority and illustrate the value of RDT evaluation under simulated field conditions.


Subject(s)
Blood Donors , Donor Selection/methods , Emergency Medical Services , Hepatitis C Antibodies/blood , Reagent Kits, Diagnostic , Algorithms , Blood Donors/statistics & numerical data , Blood Preservation/methods , Blood Safety , Clinical Laboratory Techniques/instrumentation , Clinical Laboratory Techniques/methods , Efficiency , Emergency Medical Services/methods , Emergency Medical Services/standards , Hepatitis C/blood , Hepatitis C/diagnosis , Hepatitis C Antibodies/analysis , Humans , Reagent Kits, Diagnostic/standards , Sensitivity and Specificity , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...