Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38861398

ABSTRACT

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Subject(s)
Defibrillators, Implantable , Electric Countershock , Registries , Humans , Male , Retrospective Studies , Female , Middle Aged , Incidence , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Aged , Europe/epidemiology , Equipment Failure/statistics & numerical data , United States/epidemiology , Risk Factors
2.
Europace ; 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38885309

ABSTRACT

AIMS AND BACKGROUND: Subcutaneous implantable cardioverter-defibrillators (S-ICD) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD) which led to an advisory for nearly 40,000 patients. This multicenter study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across 9 centers in Europe and the USA was reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity were analyzed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data was obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on clinicaltrials.gov (NCT05713708). RESULTS: Of the 1,112 S-ICD devices analyzed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under FDA advisory. The median follow-up time for all patients was 46 (IQR 24-63) months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.

4.
Eur Heart J ; 45(10): 837-849, 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-37956458

ABSTRACT

BACKGROUND AND AIMS: Patients with long atrial high-rate episodes (AHREs) ≥24 h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients. METHODS: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors. The primary efficacy outcome was a composite of stroke, systemic embolism, or cardiovascular death. The safety outcome was a composite of major bleeding and death. Key secondary outcomes were components of these outcomes and electrocardiogram (ECG)-diagnosed atrial fibrillation. RESULTS: Median follow-up of 2389 patients with core lab-verified AHRE was 1.8 years. AHRE ≥24 h were present at baseline in 259/2389 patients (11%, 78 ± 7 years old, 28% women, CHA2DS2-VASc 4). Clinical characteristics were not different from patients with shorter AHRE. The primary outcome occurred in 9/132 patients with AHRE ≥24 h (4.3%/patient-year, 2 strokes) treated with anticoagulation and in 14/127 patients treated with placebo (6.9%/patient-year, 2 strokes). Atrial high-rate episode duration did not interact with the efficacy (P-interaction = .65) or safety (P-interaction = .98) of anticoagulation. Analyses including AHRE as a continuous parameter confirmed this. Patients with AHRE ≥24 h developed more ECG-diagnosed atrial fibrillation (17.0%/patient-year) than patients with shorter AHRE (8.2%/patient-year; P < .001). CONCLUSIONS: This hypothesis-generating analysis does not find an interaction between AHRE duration and anticoagulation therapy in patients with device-detected AHRE and stroke risk factors. Further research is needed to identify patients with long AHRE at high stroke risk.


Subject(s)
Atrial Fibrillation , Pyridines , Stroke , Thiazoles , Humans , Female , Aged , Aged, 80 and over , Male , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Atrial Fibrillation/diagnosis , Heart Atria , Risk Factors , Stroke/etiology , Stroke/prevention & control , Stroke/diagnosis , Anticoagulants/therapeutic use
5.
Circulation ; 149(13): 981-988, 2024 03 26.
Article in English | MEDLINE | ID: mdl-37952187

ABSTRACT

BACKGROUND: Device-detected atrial fibrillation (also known as subclinical atrial fibrillation or atrial high-rate episodes) is a common finding in patients with an implanted cardiac rhythm device and is associated with an increased risk of ischemic stroke. Whether oral anticoagulation is effective and safe in this patient population is unclear. METHODS: We performed a systematic review of MEDLINE and Embase for randomized trials comparing oral anticoagulation with antiplatelet or no antithrombotic therapy in adults with device-detected atrial fibrillation recorded by a pacemaker, implantable cardioverter defibrillator, cardiac resynchronization therapy device, or implanted cardiac monitor. We used random-effects models for meta-analysis and rated the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation framework (GRADE). The review was preregistered (PROSPERO CRD42023463212). RESULTS: From 785 citations, we identified 2 randomized trials with relevant clinical outcome data: NOAH-AFNET 6 (Non-Vitamin K Antagonist Oral Anticoagulants in Patients With Atrial High Rate Episodes; 2536 participants) evaluated edoxaban, and ARTESiA (Apixaban for the Reduction of Thrombo-Embolism in Patients With Device-Detected Sub-Clinical Atrial Fibrillation; 4012 participants) evaluated apixaban. Meta-analysis demonstrated that oral anticoagulation with these agents reduced ischemic stroke (relative risk [RR], 0.68 [95% CI, 0.50-0.92]; high-quality evidence). The results from the 2 trials were consistent (I2 statistic for heterogeneity=0%). Oral anticoagulation also reduced a composite of cardiovascular death, all-cause stroke, peripheral arterial embolism, myocardial infarction, or pulmonary embolism (RR, 0.85 [95% CI, 0.73-0.99]; I2=0%; moderate-quality evidence). There was no reduction in cardiovascular death (RR, 0.95 [95% CI, 0.76-1.17]; I2=0%; moderate-quality evidence) or all-cause mortality (RR, 1.08 [95% CI, 0.96-1.21]; I2=0%; moderate-quality evidence). Oral anticoagulation increased major bleeding (RR, 1.62 [95% CI, 1.05-2.50]; I²=61%; high-quality evidence). CONCLUSIONS: The results of the NOAH-AFNET 6 and ARTESiA trials are consistent with each other. Meta-analysis of these 2 large randomized trials provides high-quality evidence that oral anticoagulation with edoxaban or apixaban reduces the risk of stroke in patients with device-detected atrial fibrillation and increases the risk of major bleeding.


Subject(s)
Anticoagulants , Atrial Fibrillation , Embolism , Ischemic Stroke , Stroke , Humans , Administration, Oral , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Atrial Fibrillation/drug therapy , Embolism/etiology , Hemorrhage/prevention & control , Pyridines , Stroke/epidemiology , Stroke/prevention & control , Thiazoles , Treatment Outcome , Randomized Controlled Trials as Topic
6.
J Clin Med ; 12(21)2023 Oct 26.
Article in English | MEDLINE | ID: mdl-37959246

ABSTRACT

Aim. Pharmacologic reduction in heart rate with beta-blockers (BB) or ivabradine is associated with improved survival in heart failure (HF) with sinus rhythm. We analyzed the association of different heart rate-reducing drug treatments on outcomes in HF outpatients. Methods. Consecutive patients with HF in sinus rhythm referred to a specialized tertiary service were prospectively enrolled from August 2015 until March 2018. Clinical characteristics were assessed at baseline. We performed Cox regression analyses to examine the effect of the resting heart rate and different heart rate-reducing drug regimens on all-cause mortality and a composite endpoint of "all-cause mortality or heart transplantation" over a mean follow-up of 3.1 years. Results. Of the 278 patients included, 213 (76.6%) were male, the median age was 57.0 years (IQR 49.0-66.1), and 185 (73.7%) had an ejection fraction <40%. Most patients received BB in submaximal [n = 118] or maximum dose [n = 136]. Patients on BB in maximum dose plus ivabradine [n = 24] were younger (53.0 vs. 58.0 years) and had a lower EF (25 vs. 31%). Higher resting heart rate was associated with an increased risk of death or transplantation (HR 1.03 [1.01, 1.06], p = 0.0072), even after adjusting for age and sex. There were no differences between the groups concerning all-cause mortality or the composite endpoint. Conclusion. Our prospective study confirms the association between low heart rate and survival in HF patients receiving various heart rate-reducing medications. We could not identify a specific effect of either regimen.

7.
N Engl J Med ; 389(13): 1167-1179, 2023 Sep 28.
Article in English | MEDLINE | ID: mdl-37622677

ABSTRACT

BACKGROUND: Device-detected atrial high-rate episodes (AHREs) are atrial arrhythmias detected by implanted cardiac devices. AHREs resemble atrial fibrillation but are rare and brief. Whether the occurrence of AHREs in patients without atrial fibrillation (as documented on a conventional electrocardiogram [ECG]) justifies the initiation of anticoagulants is not known. METHODS: We conducted an event-driven, double-blind, double-dummy, randomized trial involving patients 65 years of age or older who had AHREs lasting for at least 6 minutes and who had at least one additional risk factor for stroke. Patients were randomly assigned in a 1:1 ratio to receive edoxaban or placebo. The primary efficacy outcome was a composite of cardiovascular death, stroke, or systemic embolism, evaluated in a time-to-event analysis. The safety outcome was a composite of death from any cause or major bleeding. RESULTS: The analysis population consisted of 2536 patients (1270 in the edoxaban group and 1266 in the placebo group). The mean age was 78 years, 37.4% were women, and the median duration of AHREs was 2.8 hours. The trial was terminated early, at a median follow-up of 21 months, on the basis of safety concerns and the results of an independent, informal assessment of futility for the efficacy of edoxaban; at termination, the planned enrollment had been completed. A primary efficacy outcome event occurred in 83 patients (3.2% per patient-year) in the edoxaban group and in 101 patients (4.0% per patient-year) in the placebo group (hazard ratio, 0.81; 95% confidence interval [CI], 0.60 to 1.08; P = 0.15). The incidence of stroke was approximately 1% per patient-year in both groups. A safety outcome event occurred in 149 patients (5.9% per patient-year) in the edoxaban group and in 114 patients (4.5% per patient-year) in the placebo group (hazard ratio, 1.31; 95% CI, 1.02 to 1.67; P = 0.03). ECG-diagnosed atrial fibrillation developed in 462 of 2536 patients (18.2% total, 8.7% per patient-year). CONCLUSIONS: Among patients with AHREs detected by implantable devices, anticoagulation with edoxaban did not significantly reduce the incidence of a composite of cardiovascular death, stroke, or systemic embolism as compared with placebo, but it led to a higher incidence of a composite of death or major bleeding. The incidence of stroke was low in both groups. (Funded by the German Center for Cardiovascular Research and others; NOAH-AFNET 6 ClinicalTrials.gov number, NCT02618577; ISRCTN number, ISRCTN17309850.).


Subject(s)
Anticoagulants , Arrhythmias, Cardiac , Embolism , Factor Xa Inhibitors , Aged , Female , Humans , Male , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Embolism/drug therapy , Embolism/etiology , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/therapeutic use , Hemorrhage/chemically induced , Stroke/etiology , Stroke/prevention & control , Electrodes, Implanted , Double-Blind Method , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...