Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Physiol ; 597(5): 1337-1346, 2019 03.
Article in English | MEDLINE | ID: mdl-30552684

ABSTRACT

KEY POINTS: Intense physical activity, a potent stimulus for sympathetic nervous system activation, is thought to increase the risk of malignant ventricular arrhythmias among patients with hypertrophic cardiomyopathy (HCM). As a result, the majority of patients with HCM deliberately reduce their habitual physical activity after diagnosis and this lifestyle change puts them at risk for sequelae of a sedentary lifestyle: weight gain, hypertension, hyperlipidaemia, insulin resistance, coronary artery disease, and increased morbidity and mortality. We show that plasma catecholamine levels remain stably low at exercise intensities below the ventilatory threshold, a parameter that can be defined during cardiopulmonary exercise testing, but rise rapidly at higher intensities of exercise. These findings suggest that cardiopulmonary exercise testing may be a useful tool to provide an individualized moderate-intensity exercise prescription for patients with HCM. ABSTRACT: Intense physical activity, a potent stimulus for sympathetic nervous system activation, is thought to increase the risk of malignant ventricular arrhythmias among patients with hypertrophic cardiomyopathy (HCM). However, the impact of exercise intensity on plasma catecholamine levels among HCM patients has not been rigorously defined. We conducted a prospective observational case-control study of men with non-obstructive HCM and age-matched controls. Laboratory-based cardiopulmonary exercise testing coupled with serial phlebotomy was used to define the relationship between exercise intensity and plasma catecholamine levels. Compared to controls (C, n = 5), HCM participants (H, n = 9) demonstrated higher left ventricular mass index (115 ± 20 vs. 90 ± 16 g/m2 , P = 0.03) and maximal left ventricular wall thickness (16 ± 1 vs. 8 ± 1 mm, P < 0.001) but similar body mass index, resting heart rate, peak oxygen consumption (H = 40 ± 13 vs. C = 42 ± 7 ml/kg/min, P = 0.81) and heart rate at the ventilatory threshold (H = 78 ± 6 vs. C = 78 ± 4% peak heart rate, P = 0.92). During incremental effort exercise in both groups, concentrations of adrenaline and noradrenaline were unchanged through low- and moderate-exercise intensity until reaching a catecholamine threshold (H = 82 ± 4 vs. C = 85 ± 3% peak heart rate, P = 0.86) after which levels of both molecules rose rapidly. In patients with mild non-obstructive HCM, plasma catecholamine levels remain stably low at exercise intensities below the ventilatory threshold but rise rapidly at higher intensities of exercise. Routine cardiopulmonary exercise testing may be a useful tool to provide an individualized moderate-intensity exercise prescription for patients with HCM.


Subject(s)
Cardiomyopathy, Hypertrophic/rehabilitation , Epinephrine/blood , Exercise Therapy , Norepinephrine/blood , Adult , Cardiomyopathy, Hypertrophic/blood , Cardiomyopathy, Hypertrophic/physiopathology , Exercise/physiology , Exercise Test , Heart Rate , Heart Ventricles/physiopathology , Humans , Male , Young Adult
3.
J Am Soc Echocardiogr ; 31(4): 491-504, 2018 04.
Article in English | MEDLINE | ID: mdl-28843367

ABSTRACT

Isolated reoperative tricuspid valve replacement is one of the highest risk operations classified in the Society of Thoracic Surgeons registry, particularly in the setting of preexisting right ventricular dysfunction. Transcatheter tricuspid valve-in-valve implantation represents an attractive alternative to redo surgery in patients with tricuspid bioprosthetic valve degeneration who are considered high-risk or unsuitable surgical candidates. In this review article, the authors discuss the emergence of transcatheter tricuspid valve-in-valve therapy, preprocedural echocardiographic assessment of tricuspid bioprosthetic valve dysfunction, periprocedural imaging required for tricuspid valve-in-valve implantation, and postprocedural assessment of tricuspid transcatheter device function.


Subject(s)
Bioprosthesis/adverse effects , Cardiac Catheterization/methods , Echocardiography/methods , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Tricuspid Valve/surgery , Heart Valve Diseases/diagnosis , Humans , Prosthesis Design , Prosthesis Failure , Reoperation , Tricuspid Valve/diagnostic imaging
4.
Interv Cardiol Clin ; 6(4): 505-524, 2017 10.
Article in English | MEDLINE | ID: mdl-28886842

ABSTRACT

Transcatheter closure of atrial septal defects and patent foramen ovale has become increasingly common with advances in device and imaging technology. The percutaneous approach is now the preferred method of closure when anatomically suitable. Two-dimensional and 3-dimensional echocardiography determines anatomic suitability by characterizing the interatrial defect and its surrounding structures, and is critical for intraprocedural guidance and postprocedure follow-up. This article provides an overview of interatrial anatomy as it pertains to interventional considerations and discusses the transthoracic, transesophageal, and intracardiac echocardiographic modalities used for periprocedural and intraprocedural imaging of the interatrial septum.


Subject(s)
Cardiac Catheterization/methods , Cardiac Surgical Procedures/methods , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Foramen Ovale, Patent/diagnosis , Ultrasonography, Interventional/methods , Atrial Septum , Foramen Ovale, Patent/surgery , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...