Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Circulation ; 114(1 Suppl): I504-11, 2006 Jul 04.
Article in English | MEDLINE | ID: mdl-16820628

ABSTRACT

BACKGROUND: The autograft procedure, an option in aortic valve replacement, has undergone technical evolution. A considerable debate about the most favorable surgical technique in the Ross operation is still ongoing. Originally described as a subcoronary implant, the full root replacement technique is now the most commonly used technique to perform the Ross principle. METHODS AND RESULTS: Between June of 1994 and June of 2005, the original subcoronary autograft technique was performed in 347 patients. Preoperative, perioperative, and follow-up data were collected and analyzed. Mean patient age at implantation was 44+/-13 years (range 14 to 71 years; 273 male, 74 female). Bicuspid valve morphology was present in 67%. The underlying valve disease was aortic regurgitation in 111 patients, stenosis in 46 patients, combined lesion in 188 patients, and active endocarditis in 22 patients (in 2 patients without stenosis or regurgitation). Concomitant procedures were performed in 130 patients. Clinical and echocardiographic follow-up visits were obtained annually (mean follow up 3.9+/-2.7 years, 1324 patient-years; completeness of follow-up 99.4%). The in-hospital mortality rate was 0.6% (n =2), and the late mortality was 1.7% (n=6), with 5 noncardiac deaths (4 cancer, 1 multiorgan failure after noncardiac surgery) and 1 cardiac death (sudden death). At last follow-up, 94% of the surviving patients were in New York Heart Association class I. Ross procedure-related valvular reoperations were necessary in 9 patients: Three received autograft explants, 5 received homograft explants, and 1 received a combined auto- and homograft explant. At last follow-up visit, autograft/homograft regurgitation grade II was present in 5/10 patients and grade III in 4/0. Maximum/mean pressure gradients were 7.4+/-6.2/3.7+/-2.1 mm Hg across the autograft and 15.3+/-9.4/7.6+/-5.0 mm Hg across the right ventricular outflow tract, respectively. Aortic root dilatation was not observed. Freedom from any valve-related intervention was 95% at 8 years (95% confidence interval 91% to 99%). CONCLUSIONS: Midterm follow-up of autograft procedures according to the original Ross subcoronary approach proves excellent clinical and hemodynamic results, with no considerable reoperation rates. Revival of the original subcoronary Ross operation should be taken into account when considering the best way to install the Ross principle.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Pulmonary Valve/transplantation , Adolescent , Adult , Aged , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Death, Sudden, Cardiac , Disease-Free Survival , Endocarditis/surgery , Female , Follow-Up Studies , Heart Failure/epidemiology , Heart Failure/etiology , Humans , Intracranial Embolism/epidemiology , Life Tables , Male , Middle Aged , Multiple Organ Failure/mortality , Myocardial Infarction/epidemiology , Neoplasms/mortality , Postoperative Complications/mortality , Prospective Studies , Reoperation , Transplantation, Autologous , Transplantation, Heterotopic , Transplantation, Homologous , Treatment Outcome , Ultrasonography
2.
Circulation ; 112(9 Suppl): I415-22, 2005 Aug 30.
Article in English | MEDLINE | ID: mdl-16159856

ABSTRACT

BACKGROUND: Return of left ventricular mass to normal is considered to be a favorable result of aortic valve replacement. The Ross procedure provides near normal hemodynamics and thus allows studies of left ventricular (LV) reverse remodeling. LV mass regression may be influenced by surgical technique (subcoronary [SC] versus root replacement [RR]). METHODS AND RESULTS: Data from the German Ross Registry were analyzed. A total of 646 patients (mean age: 43.6+/-12.7 years, range: 16 to 71 years; SC technique n=295, RR technique n=351) underwent a Ross procedure in 7 participating centers from 1990 to 2004. The patients underwent preoperative and postoperative echocardiographic evaluations. Mean follow-up time was 3.5+/-2.5 years (range 0.12 to 13.7 years). Follow-up completeness was 97%. The LV mass index (LVMI) decreased significantly during follow-up in both groups (SC: 209+/-53 preoperatively to 154+/-48 at 1-year follow-up, [P<0.01 versus preoperative values] to 149+/-51 g/m2 at 2-year follow-up, [P=NS 1-year versus 2-year follow-up] versus RR: from 195+/-56 preoperatively to 144+/-51 at 1-year follow-up [P<0.01 versus preoperative values] to 140+/-49 g/m2 [P=NS 1-year versus 2-year follow-up]). LVMI regression remained stagnant 1 year after the Ross procedure in most patients in both groups. On the basis of multivariate analysis, predictors for incomplete LVMI regression after the autograft procedure were high preoperative LVMI, smoking, and uncontrolled diastolic hypertension. CONCLUSIONS: At mid-term echocardiographic follow-up, patients of both groups had favorable autograft hemodynamics. Risk factors for incomplete postoperative LVMI regression in our study were smoking and persistent diastolic hypertension. This emphasizes the importance of cessation of smoking and treatment of arterial hypertension, even in younger patients, after corrected aortic valve disease.


Subject(s)
Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Hypertrophy, Left Ventricular/surgery , Pulmonary Valve/transplantation , Adolescent , Adult , Aged , Cardiopulmonary Bypass , Female , Follow-Up Studies , Germany/epidemiology , Humans , Hypertrophy, Left Ventricular/diagnostic imaging , Hypertrophy, Left Ventricular/etiology , Hypertrophy, Left Ventricular/physiopathology , Male , Middle Aged , Organ Size , Polyethylene Terephthalates , Prostheses and Implants , Registries/statistics & numerical data , Suture Techniques , Transplantation, Autologous , Transplantation, Heterotopic , Ultrasonography , Ventricular Remodeling
SELECTION OF CITATIONS
SEARCH DETAIL
...