Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 437
Filter
1.
Obstet Gynecol ; 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38995956

ABSTRACT

OBJECTIVE: To evaluate whether continuous glucose monitoring (CGM)-derived glycemic patterns observed throughout pregnancy were associated with adverse perinatal outcomes, specifically fetal growth disorders and hypertensive disorders of pregnancy (HDP). METHODS: We conducted a prospective observational study of individuals with viable singleton pregnancies and screening hemoglobin A1c levels less than 6.5%. Those with preexisting diabetes were excluded. Enrollment occurred at the earliest gestational age before 17 weeks. Participants wore blinded continuous glucose monitors consecutively as willing until delivery. Those with at least 14 days of CGM data were included in analysis. Rates of large-for-gestational-age (LGA) neonates, small-for-gestational age (SGA) neonates, and HDP were assessed. Continuous glucose monitoring-derived glycemic metrics were calculated, including mean glucose level and percent time above and below thresholds. Two-sample t tests were used to compare glycemic metrics between participants with and without adverse perinatal outcomes. RESULTS: Of 937 participants enrolled, 760 met inclusion criteria. Those delivering LGA neonates or who were diagnosed with HDP had higher mean glucose levels (102±9 vs 100±8, P=.01 and 103±8 vs 99±8, P<.001) and spent more time above 120 mg/dL (median 16% vs 12%, P=.006, and 16% vs 12%, P<.001, respectively) and above 140 mg/dL (median 3.9% vs 2.8%, P=.006, and 3.5% vs 2.8%, P<.001, respectively) throughout gestation than those without these outcomes. These findings were present regardless of gestational diabetes mellitus status. Participants with SGA neonates had lower mean glucose levels (97±7 vs 101±8, P=.01) and spent less time above 140 mg/dL (median 1.6% vs 2.3%, P=.01) and more time below 63 mg/dL (median 3.0% vs 2.3%, P=.02) than those without SGA neonates. CONCLUSION: Individuals with LGA neonates or HDP exhibit a slightly higher mean glucose levels and spend more time hyperglycemic in early pregnancy than those who do not experience these outcomes.

2.
J Clin Transl Endocrinol ; 36: 100352, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38860154

ABSTRACT

Objectives: To report the safety and side effects associated with taking verapamil for beta-cell preservation in children with newly-diagnosed T1D. Research Design and Methods: Eighty-eight participants aged 8.5 to 17.9 years weighing ≥ 30 kg were randomly assigned to verapamil (N = 47) or placebo (N = 41) within 31 days of T1D diagnosis and followed for 12 months from diagnosis, main CLVer study. Drug dosing was weight-based with incremental increases to full dosage. Side effect monitoring included serial measurements of pulse, blood pressure, liver enzymes, and electrocardiograms (ECGs). At study end, participants were enrolled in an observational extension study (CLVerEx), which is ongoing. No study drug is provided during the extension, but participants may use verapamil if prescribed by their diabetes care team. Results: Overall rates of adverse events were low and comparable between verapamil and placebo groups. There was no difference in the frequency of liver function abnormalities. Three CLVer participants reduced or discontinued medication due to asymptomatic ECG changes. One CLVerEx participant (18 years old), treated with placebo during CLVer, who had not had a monitoring ECG, experienced complete AV block with a severe hypotensive episode 6 weeks after reaching his maximum verapamil dose following an inadvertent double dose on the day of the event. Conclusions: The use of verapamil in youth newly-diagnosed with T1D appears generally safe and well tolerated with appropriate monitoring. We strongly recommend monitoring for potential side effects including an ECG at screening and an additional ECG once full dosage is reached.ClinicalTrials.gov number: NCT04233034.

3.
Diabetes Care ; 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701400

ABSTRACT

OBJECTIVE: To determine whether continuous glucose monitoring (CGM)-derived glycemic patterns can characterize pregnancies with gestational diabetes mellitus (GDM) as diagnosed by standard oral glucose tolerance test at 24-28 weeks' gestation compared with those without GDM. RESEARCH DESIGN AND METHODS: The analysis includes 768 individuals enrolled from two sites prior to 17 weeks' gestation between June 2020 and December 2021 in a prospective observational study. Participants wore blinded Dexcom G6 CGMs throughout gestation. Main outcome of interest was a diagnosis of GDM by oral glucose tolerance test (OGTT). Glycemic levels in participants with GDM versus without GDM were characterized using CGM-measured glycemic metrics. RESULTS: Participants with GDM (n = 58 [8%]) had higher mean glucose (109 ± 13 vs. 100 ± 8 mg/dL [6.0 ± 0.7 vs. 5.6 ± 0.4 mmol/L], P < 0.001), greater glucose SD (23 ± 4 vs. 19 ± 3 mg/dL [1.3 ± 0.2 vs. 1.1 ± 0.2 mmol/L], P < 0.001), less time in range 63-120 mg/dL (3.5-6.7 mmol/L) (70% ± 17% vs. 84% ± 8%, P < 0.001), greater percent time >120 mg/dL (>6.7 mmol/L) (median 23% vs. 12%, P < 0.001), and greater percent time >140 mg/dL (>7.8 mmol/L) (median 7.4% vs. 2.7%, P < 0.001) than those without GDM throughout gestation prior to OGTT. Median percent time >120 mg/dL (>6.7 mmol/L) and time >140 mg/dL (>7.8 mmol/L) were higher as early as 13-14 weeks of gestation (32% vs. 14%, P < 0.001, and 5.2% vs. 2.0%, P < 0.001, respectively) and persisted during the entire study period prior to OGTT. CONCLUSIONS: Prior to OGTT at 24-34 weeks' gestation, pregnant individuals who develop GDM have higher CGM-measured glucose levels and more hyperglycemia compared with those who do not develop GDM.

5.
J Diabetes Sci Technol ; : 19322968241254811, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38805364

ABSTRACT

BACKGROUND: We investigated the risk of incident diabetic retinopathy (DR) among high glycator compared to low glycator patients based on the hemoglobin glycation index (HGI). Visit-to-visit variations in HGI also were assessed. METHODS: Glycated hemoglobin (HbA1c) and continuous glucose monitoring data were collected up to 7 years prior to the date of eye examination defining incident DR or no retinopathy (control). Hemoglobin glycation index was calculated as difference in measured HbA1c and an estimated A1c from sensor glucose (eA1c) to define high (HbA1c - eA1c >0%) or low (HbA1c - eA1c <0%) glycator. Stable glycators were defined as ≥75% of visits with same HGI category. Logistic regression was used to assess the association between glycation category and incident DR. RESULTS: Of 119 adults with type 1 diabetes (T1D), 49 (41%) were stable low glycator (HbA1c - eA1c <0%), 36 (30%) were stable high glycator (HbA1c - eA1c >0%), and 34 (29%) were unstable glycator. Using alternate criteria to define high vs low glycator (consistent difference in HbA1c - eA1c of > 0.4% or <0.4%, respectively), 53% of the adults were characterized as unstable glycator. Compared to low glycators, high glycators did not have a significantly higher risk for incident DR over time when adjusted for age, T1D duration and continuous glucose monitoring (CGM) sensor type (odds ratio [OR] = 1.31, 95% confidence interval [CI] = 0.48-3.62, P = .15). CONCLUSIONS: The risk of diabetic retinopathy was not found to differ significantly comparing high glycators to low glycators in adults with T1D. Moreover, HbA1c - eA1c relationship was not stable in nearly 30% to 50% adults with T1D, suggesting that discordance in HbA1c and eA1c are mostly related either HbA1c measurements or estimation of A1c from sensor glucose rather than physiological reasons.

6.
BMJ Open Diabetes Res Care ; 12(3)2024 May 10.
Article in English | MEDLINE | ID: mdl-38729771

ABSTRACT

INTRODUCTION: To characterize glucose levels during uncomplicated pregnancies, defined as pregnancy with a hemoglobin A1c <5.7% (<39 mmol/mol) in early pregnancy, and without a large-for-gestational-age birth, hypertensive disorders of pregnancy, or gestational diabetes mellitus (ie, abnormal oral glucose tolerance test). RESEARCH DESIGN AND METHODS: Two sites enrolled 937 pregnant individuals aged 18 years and older prior to reaching 17 gestational weeks; 413 had an uncomplicated pregnancy (mean±SD body mass index (BMI) of 25.3±5.0 kg/m2) and wore Dexcom G6 continuous glucose monitoring (CGM) devices throughout the observed gestational period. Mealtimes were voluntarily recorded. Glycemic levels during gestation were characterized using CGM-measured glycemic metrics. RESULTS: Participants wore CGM for a median of 123 days each. Glucose levels were nearly stable throughout all three trimesters in uncomplicated pregnancies. Overall mean±SD glucose during gestation was 98±7 mg/dL (5.4±0.4 mmol/L), median per cent time 63-120 mg/dL (3.5-6.7 mmol/L) was 86% (IQR: 82-89%), median per cent time <63 mg/dL (3.5 mmol/L) was 1.8%, median per cent time >120 mg/dL (6.7 mmol/L) was 11%, and median per cent time >140 mg/dL (7.8 mmol/L) was 2.5%. Mean post-prandial peak glucose was 126±22 mg/dL (7.0±1.2 mmol/L), and mean post-prandial glycemic excursion was 36±22 mg/dL (2.0±1.2 mmol/L). Higher mean glucose levels were low to moderately associated with pregnant individuals with higher BMIs (103±6 mg/dL (5.7±0.3 mmol/L) for BMI ≥30.0 kg/m2 vs 96±7 mg/dL (5.3±0.4 mmol/L) for BMI 18.5-<25 kg/m2, r=0.35). CONCLUSIONS: Mean glucose levels and time 63-120 mg/dL (3.5-6.7 mmol/L) remained nearly stable throughout pregnancy and values above 140 mg/dL (7.8 mmol/L) were rare. Mean glucose levels in pregnancy trend higher as BMI increases into the overweight/obesity range. The glycemic metrics reported during uncomplicated pregnancies represent treatment targets for pregnant individuals.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Humans , Female , Pregnancy , Blood Glucose/analysis , Adult , Blood Glucose Self-Monitoring/methods , Glycated Hemoglobin/analysis , Diabetes, Gestational/blood , Diabetes, Gestational/diagnosis , Glucose Tolerance Test , Young Adult , Follow-Up Studies , Biomarkers/blood , Biomarkers/analysis , Continuous Glucose Monitoring
7.
Article in English | MEDLINE | ID: mdl-38696672

ABSTRACT

Objective: To evaluate the safety and explore the efficacy of use of ultra-rapid lispro (URLi, Lyumjev) insulin in the Tandem t:slim X2 insulin pump with Control-IQ 1.5 technology in children, teenagers, and adults living with type 1 diabetes (T1D). Methods: At 14 U.S. diabetes centers, youth and adults with T1D completed a 16-day lead-in period using lispro in a t:slim X2 insulin pump with Control-IQ 1.5 technology, followed by a 13-week period in which URLi insulin was used in the pump. Results: The trial included 179 individuals with T1D (age 6-75 years). With URLi, 1.7% (3 participants) had a severe hypoglycemia event over 13 weeks attributed to override boluses or a missed meal. No diabetic ketoacidosis events occurred. Two participants stopped URLi use because of infusion-site discomfort, and one stopped after developing a rash. Mean time 70-180 mg/dL increased from 65% ± 15% with lispro to 67% ± 13% with URLi (P = 0.004). Mean insulin treatment satisfaction questionnaire score improved from 75 ± 13 at screening to 80 ± 11 after 13 weeks of URLi use (mean difference = 6; 95% confidence interval 4-8; P < 0.001), with the greatest improvement reported for confidence avoiding symptoms of high blood sugar. Mean treatment-related impact measure-diabetes score improved from 74 ± 12 to 80 ± 12 (P < 0.001), and mean TRIM-Diabetes Device (score improved from 82 ± 11 to 86 ± 12 (P < 0.001). Conclusions: URLi use in the Tandem t:slim X2 insulin pump with Control-IQ 1.5 technology was safe for adult and pediatric participants with T1D, with quality-of-life benefits of URLi use perceived by the study participants. Clinicaltrials.gov registration: NCT05403502.

8.
Biomacromolecules ; 25(6): 3607-3619, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38776179

ABSTRACT

Studying how synthetic polymer assemblies respond to sequential enzymatic stimuli can uncover intricate interactions in biological systems. Using amidase- and esterase-responsive PEG-based diblock (DBA) and triblock amphiphiles (TBAs), we created two distinct formulations: amidase-responsive DBA with esterase-responsive TBA and vice versa. We studied their cascade responses to the two enzymes and the sequence of their introduction. These formulations underwent cascade mesophase transitions upon the addition of the DBA-degrading enzyme, transitioning from (i) coassembled micelles to (ii) triblock-based hydrogel, and ultimately to (iii) dissolved polymers when exposed to the TBA hydrolyzing enzyme. The specific pathway of the two mesophase transitions depended on the compositions of the formulations and the enzyme introduction sequence. The results highlight the potential for designing polymeric formulations with programmable multistep enzymatic responses, mimicking the complex behavior of biological macromolecules.


Subject(s)
Polyethylene Glycols , Polyethylene Glycols/chemistry , Micelles , Esterases/chemistry , Esterases/metabolism , Amidohydrolases/chemistry , Amidohydrolases/metabolism , Phase Transition , Polymers/chemistry , Hydrogels/chemistry
9.
J Diabetes Sci Technol ; : 19322968241234687, 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38456512

ABSTRACT

AIMS: To evaluate factors affecting within-participant reproducibility in glycemic response to different forms of exercise. METHODS: Structured exercise sessions ~30 minutes in length from the Type 1 Diabetes Exercise Initiative (T1DEXI) study were used to assess within-participant glycemic variability during and after exercise. The effect of several pre-exercise factors on the within-participant glycemic variability was evaluated. RESULTS: Data from 476 adults with type 1 diabetes were analyzed. A participant's change in glucose during exercise was reproducible within 15 mg/dL of the participant's other exercise sessions only 32% of the time. Participants who exercised with lower and more consistent glucose level, insulin on board (IOB), and carbohydrate intake at exercise start had less variability in glycemic change during exercise. Participants with lower mean glucose (P < .001), lower glucose coefficient of variation (CV) (P < .001), and lower % time <70 mg/dL (P = .005) on sedentary days had less variable 24-hour post-exercise mean glucose. CONCLUSIONS: Reproducibility of change in glucose during exercise was low in this cohort of adults with T1D, but more consistency in pre-exercise glucose levels, IOB, and carbohydrates may increase this reproducibility. Mean glucose variability in the 24 hours after exercise is influenced more by the participant's overall glycemic control than other modifiable factors.

10.
Diabetologia ; 67(6): 1009-1022, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38502241

ABSTRACT

AIMS/HYPOTHESIS: Adults with type 1 diabetes should perform daily physical activity to help maintain health and fitness, but the influence of daily step counts on continuous glucose monitoring (CGM) metrics are unclear. This analysis used the Type 1 Diabetes Exercise Initiative (T1DEXI) dataset to investigate the effect of daily step count on CGM-based metrics. METHODS: In a 4 week free-living observational study of adults with type 1 diabetes, with available CGM and step count data, we categorised participants into three groups-below (<7000), meeting (7000-10,000) or exceeding (>10,000) the daily step count goal-to determine if step count category influenced CGM metrics, including per cent time in range (TIR: 3.9-10.0 mmol/l), time below range (TBR: <3.9 mmol/l) and time above range (TAR: >10.0 mmol/l). RESULTS: A total of 464 adults with type 1 diabetes (mean±SD age 37±14 years; HbA1c 48.8±8.1 mmol/mol [6.6±0.7%]; 73% female; 45% hybrid closed-loop system, 38% standard insulin pump, 17% multiple daily insulin injections) were included in the study. Between-participant analyses showed that individuals who exceeded the mean daily step count goal over the 4 week period had a similar TIR (75±14%) to those meeting (74±14%) or below (75±16%) the step count goal (p>0.05). In the within-participant comparisons, TIR was higher on days when the step count goal was exceeded or met (both 75±15%) than on days below the step count goal (73±16%; both p<0.001). The TBR was also higher when individuals exceeded the step count goals (3.1%±3.2%) than on days when they met or were below step count goals (difference in means -0.3% [p=0.006] and -0.4% [p=0.001], respectively). The total daily insulin dose was lower on days when step count goals were exceeded (0.52±0.18 U/kg; p<0.001) or were met (0.53±0.18 U/kg; p<0.001) than on days when step counts were below the current recommendation (0.55±0.18 U/kg). Step count had a larger effect on CGM-based metrics in participants with a baseline HbA1c ≥53 mmol/mol (≥7.0%). CONCLUSIONS/INTERPRETATION: Our results suggest that, compared with days with low step counts, days with higher step counts are associated with slight increases in both TIR and TBR, along with small reductions in total daily insulin requirements, in adults living with type 1 diabetes. DATA AVAILABILITY: The data that support the findings reported here are available on the Vivli Platform (ID: T1-DEXI; https://doi.org/10.25934/PR00008428 ).


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Diabetes Mellitus, Type 1 , Exercise , Humans , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/therapy , Diabetes Mellitus, Type 1/drug therapy , Adult , Female , Male , Blood Glucose Self-Monitoring/methods , Blood Glucose/metabolism , Blood Glucose/analysis , Middle Aged , Exercise/physiology , Glycated Hemoglobin/metabolism , Glycated Hemoglobin/analysis , Insulin/therapeutic use , Insulin/administration & dosage , Cohort Studies , Continuous Glucose Monitoring
11.
J Diabetes Sci Technol ; : 19322968241231950, 2024 Mar 17.
Article in English | MEDLINE | ID: mdl-38494876

ABSTRACT

BACKGROUND/OBJECTIVE: The main objective of this study is to evaluate the incremental cost-effectiveness (ICER) of the Cambridge hybrid closed-loop automated insulin delivery (AID) algorithm versus usual care for children and adolescents with type 1 diabetes (T1D). METHODS: This multicenter, binational, parallel-controlled trial randomized 133 insulin pump using participants aged 6 to 18 years to either AID (n = 65) or usual care (n = 68) for 6 months. Both within-trial and lifetime cost-effectiveness were analyzed. Analysis focused on the treatment subgroup (n = 21) who received the much more reliable CamAPS FX hardware iteration and their contemporaneous control group (n = 24). Lifetime complications and costs were simulated via an updated Sheffield T1D policy model. RESULTS: Within-trial, both groups had indistinguishable and statistically unchanged health-related quality of life, and statistically similar hypoglycemia, severe hypoglycemia, and diabetic ketoacidosis (DKA) event rates. Total health care utilization was higher in the treatment group. Both the overall treatment group and CamAPS FX subgroup exhibited improved HbA1C (-0.32%, 95% CI: -0.59 to -0.04; P = .02, and -1.05%, 95% CI: -1.43 to -0.67; P < .001, respectively). Modeling projected increased expected lifespan of 5.36 years and discounted quality-adjusted life years (QALYs) of 1.16 (U.K. tariffs) and 1.52 (U.S. tariffs) in the CamAPS FX subgroup. Estimated ICERs for the subgroup were £19 324/QALY (United Kingdom) and -$3917/QALY (United States). For subgroup patients already using continuous glucose monitors (CGM), ICERs were £10 096/QALY (United Kingdom) and -$33 616/QALY (United States). Probabilistic sensitivity analysis generated mean ICERs of £19 342/QALY (95% CI: £15 903/QALY to £22 929/QALY) (United Kingdom) and -$28 283/QALY (95% CI: -$59 607/QALY to $1858/QALY) (United States). CONCLUSIONS: For children and adolescents with T1D on insulin pump therapy, AID using the Cambridge algorithm appears cost-effective below a £20 000/QALY threshold (United Kingdom) and cost saving (United States).

12.
Article in English | MEDLINE | ID: mdl-38441232

ABSTRACT

OBJECTIVE: To assess whether impaired awareness of hypoglycemia (IAH) affects exercise-associated hypoglycemia in adults with type 1 diabetes (T1D). METHODS: We compared continuous glucose monitoring (CGM)-measured glucose during exercise and for 24-hours following exercise from 95 adults with T1D and IAH (Clarke score ≥4 or ≥1 severe hypoglycemic event within the past year) to 95 'Aware' adults (Clarke score ≤2 and no severe hypoglycemic event within the past year) matched on sex, age, insulin delivery modality, and HbA1c. A total of 4,236 exercise sessions, and 1,794 exercise days and 839 sedentary days, defined as 24-hours following exercise or a day without exercise, respectively, were available for analysis. RESULTS: Participants with IAH exhibited a non-significant trend towards greater decline in glucose during exercise compared to 'Aware' (-21 ± 44 vs. -19 ± 43 mg/dL [-1.17 ± 2.44 vs. -1.05 ± 2.39 mmol/L], adjusted group difference of -4.2 [95% CI: -8.4 to 0.05] mg/dL [-0.23 95% CI: -0.47 to 0.003 mmol/L], P = 0.051). Individuals with IAH had higher proportion of days with hypoglycemic events <70 mg/dL[3.89 mmol/L] (≥15 minutes <70 mg/dL[<3.89 mmol/L]) both on exercise days (51% vs. 43%, P = 0.006) and sedentary days (48% vs. 30%, P = 0.001). The increased odds of experiencing a hypoglycemic event <70 mg/dL[<3.89 mmol/L] for individuals with IAH compared to 'Aware' did not differ significantly between exercise and sedentary days (interaction P = 0.36). CONCLUSION: Individuals with IAH have a higher underlying risk of hypoglycemia than 'Aware' individuals. Exercise does not appear to differentially increase risk for hypoglycemia during the activity, or in the subsequent 24-hours for IAH compared to Aware individuals with T1D.

13.
Eur Phys J E Soft Matter ; 47(2): 13, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38358563

ABSTRACT

Intrinsically disordered proteins (IDPs) are a subset of proteins that lack stable secondary structure. Given their polymeric nature, previous mean-field approximations have been used to describe the statistical structure of IDPs. However, the amino-acid sequence heterogeneity and complex intermolecular interaction network have significantly impeded the ability to get proper approximations. One such case is the intrinsically disordered tail domain of neurofilament low (NFLt), which comprises a 50 residue-long uncharged domain followed by a 96 residue-long negatively charged domain. Here, we measure two NFLt variants to identify the impact of the NFLt two main subdomains on its complex interactions and statistical structure. Using synchrotron small-angle x-ray scattering, we find that the uncharged domain of the NFLt induces attractive interactions that cause it to self-assemble into star-like polymer brushes. On the other hand, when the uncharged domain is truncated, the remaining charged N-terminal domains remain isolated in solution with typical polyelectrolyte characteristics. We further discuss how competing long- and short-ranged interactions within the polymer brushes dominate their ensemble structure and, in turn, their implications on previously observed phenomena in NFL native and diseased states.


Subject(s)
Intermediate Filaments , Intrinsically Disordered Proteins , Polyelectrolytes , Polymers , Amino Acid Sequence
14.
Diabetes Technol Ther ; 26(7): 494-497, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38386434

ABSTRACT

Background: No published data are available on the use of the community-derived open-source Loop hybrid closed-loop controller ("Loop") by individuals with type 2 diabetes (T2D). Methods: Through social media postings, we invited individuals with T2D currently using the Loop system to join an observational study. Thirteen responded of whom seven were eligible for the study, were using the Loop algorithm, and provided data. Results: Mean (±standard deviation) age was 61 ± 13 years, and mean body mass index was 31 ± 5 kg/m2. All but one participant were using noninsulin glucose-lowering medications. Self-reported mean hemoglobin A1c decreased from 7.3% ± 1.1% before starting Loop to 6.0% ± 0.5% on Loop. Time in range 70-180 mg/dL increased from 84% to 93%. The amount of time in hypoglycemia was extremely low before and with Loop (time <54 mg/dL was 0.04% ± 0.06% vs. 0.09% ± 0.07%, respectively). No severe hypoglycemia or diabetic ketoacidosis events were reported while using Loop. Conclusion: These data, though limited, suggest that the Loop system is likely to be effective when used by individuals with T2D and should be evaluated in large-scale studies. Clinical Trial Registration numbers: NCT05951569.


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 2 , Hypoglycemic Agents , Insulin Infusion Systems , Insulin , Humans , Diabetes Mellitus, Type 2/drug therapy , Diabetes Mellitus, Type 2/blood , Middle Aged , Female , Male , Insulin/administration & dosage , Insulin/therapeutic use , Aged , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/therapeutic use , Blood Glucose/analysis , Algorithms , Glycated Hemoglobin/analysis , Blood Glucose Self-Monitoring , Glycemic Control/methods , Hypoglycemia/prevention & control , Hypoglycemia/chemically induced
15.
Diabetes Res Clin Pract ; 208: 111114, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38278493

ABSTRACT

OBJECTIVE: Examine patient-reported outcomes (PROs) after the use of t:slim X2 insulin pump with Control-IQ technology (CIQ) in young children with type 1 diabetes. METHODS: Children with type 1 diabetes, ages 2 to < 6 years (n = 102), were randomly assigned 2:1 to either CIQ or standard care (SC) with pump or multiple daily injections (MDI) plus continuous glucose monitoring (CGM) for 13 weeks. Both groups were offered to use CIQ for an additional 13 weeks after the randomized control trial's (RCT) completion. Guardians completed PRO questionnaires at baseline, 13-, and 26-weeks examining hypoglycemia concerns, quality of life, parenting stress, and sleep. At 26 weeks, 28 families participated in user-experience interviews. Repeated measures analyses compared PRO scores between systems used. RESULT: Comparing CIQ vs SC, responses on all 5 PRO surveys favored the CIQ group, showing that CIQ was superior to SC at 26 weeks (p values < 0.05). User-experience interviews indicated significant benefits in optimized glycemic control overall and nighttime control (28 of 28 families endorsed). All but 2/28 families noted substantial reduction in management burden resulting in less mental burden and all but 4 stated that they wanted their children to continue using CIQ. CONCLUSIONS: Families utilizing CIQ experienced glycemic benefits coupled with substantial benefits in PROs, documented in surveys and interviews. Families utilizing CIQ had reduced hypoglycemia concerns and parenting stress, and improved quality of life and sleep. These findings demonstrate the benefit of CIQ in young children with type 1 diabetes that goes beyond documented glycemic benefit.


Subject(s)
Diabetes Mellitus, Type 1 , Hypoglycemia , Child, Preschool , Humans , Blood Glucose , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 1/drug therapy , Hypoglycemia/prevention & control , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Insulin Infusion Systems , Patient Reported Outcome Measures
16.
Clin Diabetes ; 42(1): 116-124, 2024.
Article in English | MEDLINE | ID: mdl-38230336

ABSTRACT

The t:slim X2 insulin pump with Control-IQ technology (Control-IQ) advanced hybrid closed-loop automated insulin delivery system was evaluated in this prospective single-arm trial. Thirty adults with type 2 diabetes using the Control-IQ system showed substantial glycemic improvement with no increase in hypoglycemia. Mean time in range (70-180 mg/dL) improved 15%, representing an increase of 3.6 hours/day, and mean glucose decreased by 22 mg/dL.

17.
Diabetes Technol Ther ; 26(3): 151-155, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37870460

ABSTRACT

Objective: To evaluate the relationship between continuous glucose monitoring (CGM)-measured time-in-range 70-180 mg/dL (TIR) and time-in-tight-range 70-140 mg/dL (TITR). Methods: TIR and TITR were calculated from CGM data collected using blinded or unblinded Dexcom sensors from 9 studies with 912 participants with type 1 diabetes (T1D) and 2 studies with 184 participants with type 2 diabetes (T2D). The TIR-TITR relationship was assessed overall and stratified by coefficient of variation (CV) and by time below range <70 mg/dL (TBR). Results: The correlation between TIR and TITR was 0.94. TITR was higher for a given TIR for T2D compared with T1D. However, after adjusting for the differences in CV or TBR, both of which were higher with T1D than T2D, the differences were minimized. The TIR-TITR relationship was nonlinear, with a higher ratio of TITR:TIR observed as TIR increased ranging from 0.42 when TIR was 20% to 0.66 when TIR was 80%. Similarly, as TITR increased, the ratio of TIR:TITR decreased, varying from 2.6 with TITR of 10% to 1.3 for TITR of 70%. The TIR-TITR relationship varied according to CV and TBR, such that the higher the CV or higher the amount of TBR the greater was TITR for a given TIR. Conclusions: TIR and TITR are highly correlated, although the relationship is nonlinear. With knowledge of TIR, TITR can be estimated with reasonable precision.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetes Mellitus, Type 2 , Humans , Diabetes Mellitus, Type 1/drug therapy , Diabetes Mellitus, Type 2/drug therapy , Blood Glucose , Blood Glucose Self-Monitoring , Continuous Glucose Monitoring
18.
Diabetes Technol Ther ; 26(3): 147-150, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38156959
19.
Diabetes Technol Ther ; 26(4): 246-251, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38133643

ABSTRACT

Abstract Objective: To evaluate the association between continuous glucose monitoring (CGM)-based time in various ranges and the subsequent development of diabetic retinopathy (incident DR) in adults with type 1 diabetes. Methods: Between June 2018 and March 2022, adults with type 1 diabetes with incident DR or no retinopathy (control) were identified. CGM data were collected retrospectively for up to 7 years before the date of eye examination defining incident DR or control. Associations between incident DR and CGM metrics were evaluated using logistic regression models. Results: This analysis included 71 adults with incident DR (mean age 27 years, 52% females, and mean diabetes duration 15 years) and 92 adults without DR (mean age 38 years, 48% females, and mean diabetes duration 20 years). Adjusting for age, diabetes duration, and CGM type, each 0.5% increase in glycated hemoglobin (HbA1c), 10 mg/dL increase in mean glucose, 5% decrease in time in target range 70-180 mg/dL (TIR), 5% decrease in time in tight target range 70-140 mg/dL (TITR), and 5% increase in time above 180 mg/dL (TAR) were associated with 24%, 22%, 18%, 28%, and 20% increase in odds of incident DR, respectively. Spearman correlations of TIR, TITR, TAR, and mean glucose with each other were all ≥0.97. Conclusion: Similar to HbA1c, TIR, TITR, TAR, and mean glucose were associated with increased risk for incident DR in adults with type 1 diabetes. These CGM metrics are highly correlated indicating that they provide similar information on glycemic control and diabetic retinopathy risk.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetic Retinopathy , Adult , Female , Humans , Male , Diabetes Mellitus, Type 1/complications , Glycated Hemoglobin , Blood Glucose , Longitudinal Studies , Diabetic Retinopathy/epidemiology , Diabetic Retinopathy/etiology , Diabetic Retinopathy/diagnosis , Blood Glucose Self-Monitoring/adverse effects , Retrospective Studies
20.
Sci Rep ; 13(1): 21688, 2023 12 07.
Article in English | MEDLINE | ID: mdl-38066072

ABSTRACT

The cornerstone of structural biology is the unique relationship between protein sequence and the 3D structure at equilibrium. Although intrinsically disordered proteins (IDPs) do not fold into a specific 3D structure, breaking this paradigm, some IDPs exhibit large-scale organization, such as liquid-liquid phase separation. In such cases, the structural plasticity has the potential to form numerous self-assembled structures out of thermal equilibrium. Here, we report that high-temperature incubation time is a defining parameter for micro and nanoscale self-assembly of resilin-like IDPs. Interestingly, high-resolution scanning electron microscopy micrographs reveal that an extended incubation time leads to the formation of micron-size rods and ellipsoids that depend on the amino acid sequence. More surprisingly, a prolonged incubation time also induces amino acid composition-dependent formation of short-range nanoscale order, such as periodic lamellar nanostructures. We, therefore, suggest that regulating the period of high-temperature incubation, in the one-phase regime, can serve as a unique method of controlling the hierarchical self-assembly mechanism of structurally disordered proteins.


Subject(s)
Intrinsically Disordered Proteins , Nanostructures , Intrinsically Disordered Proteins/chemistry , Protein Conformation , Temperature , Amino Acid Sequence
SELECTION OF CITATIONS
SEARCH DETAIL
...