1.
Eur Heart J Qual Care Clin Outcomes ; 9(7): 724-730, 2023 11 02.
Article in English | MEDLINE | ID: mdl-36378116

ABSTRACT

BACKGROUND: Acute decompensated aortic stenosis (ADAS) is common and associated with higher mortality, acute kidney injury (AKI) and longer hospital length of stay (LoS) compared with electively treated stable AS. The aim of this study was to assess the impact of a dedicated pathway that reduces time to transcatheter aortic valve implantation (TAVI) in ADAS, hypothesizing that LoS can be reduced without compromising patient safety. METHODS AND RESULTS: Using a prospective, open label, cluster design, patients from 5 referring centres were allocated to the ASessment and TReatment In Decompensated Aortic Stenosis (ASTRID-AS) pathway where the diagnosis, referral, investigations and treatment of ADAS were prioritised and expedited. 15 hospitals remained on the conventional pathway that followed the same process, albeit according to a waiting list. The primary efficacy endpoint was hospital LoS and the secondary safety endpoint, a composite of death or AKI at 30 days post-TAVI. 58 conventional patients and 25 ASTRID-AS patients were included in this study. Time to TAVI in the conventional vs. ASTRID-AS cohort was 22 (15-30) vs. 10 (6-12) days; P < 0.001, respectively. Length of hospital stay was 24 (18-33) vs. 13 (8-18) days; P < 0.001, respectively. 13.4 bed days were saved per patient using the ASTRID-AS pathway. Secondary safety endpoint occurred in 12 (20.7%) vs. 1 (4.0%) patients; P = 0.093, respectively. Procedural complications were similar between the two cohorts. CONCLUSION: A dedicated pathway for ADAS that shortens time to TAVI demonstrated reduced hospital LoS without compromising patient safety and a trend towards improving clinical outcomes.


Subject(s)
Acute Kidney Injury , Aortic Valve Stenosis , Humans , Pilot Projects , Prospective Studies , Treatment Outcome , Aortic Valve Stenosis/diagnosis
2.
Clin Res Cardiol ; 110(11): 1781-1791, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33978816

ABSTRACT

AIMS: Aortic stiffness, measured as aortic pulse wave velocity (PWV), is a powerful predictor of cardiovascular health but is difficult to accurately obtain non-invasively. This study sought to develop a novel CT aortic stiffness index (CTASI) which incorporates both anatomical (calcification) and physiological (distensibility) aspects of aortic health. METHODS: Invasive PWV and CT scans were obtained for 80 patients undergoing TAVI (cohort 1). CT data alone were obtained from an additional 238 patients (cohort 2). Aortic calcification was quantified using a modified Agatston's methodology. Distensibility-PWV was calculated from minimum and maximum ascending aorta areas. Linear regression of these values was used to construct CTASI from cohort 1. CTASI was then calculated for cohort 2 who were prospectively followed-up. RESULTS: CTASI correlated with invasive PWV (rho = 0.47, p < 0.01) with a higher correlation coefficient than distensibility-PWV (rho = 0.35, p < 0.01) and aortic calcification (rho = 0.36, p < 0.01). Compared to invasive PWV, CTASI had a good accuracy as a diagnostic test (AOC 0.72 [95% CI 0.61-0.84]), superior to aortic calcification and distensibility-PWV alone (χ2 = 0.82, p = 0.02). There were 61 deaths during a median follow-up of 771 days (95% CI 751.4-790.5). CTASI was able to predict 1-year mortality (OR 2.58, 95% CI 1.18-5.61, p = 0.02) and Kaplan-Meier survival (log-rank p = 0.03). CONCLUSION: CTASI is a stronger measure of aortic stiffness than aortic calcification or distensibility alone. Given the prolific use of CT scanning for assessing coronary and vascular disease, the additional calculation of CTASI during these scans could provide an important direct measurement of vascular health and guide pharmacological therapy.


Subject(s)
Aorta, Thoracic/diagnostic imaging , Cardiovascular Diseases/diagnosis , Tomography, X-Ray Computed/methods , Vascular Stiffness/physiology , Aged, 80 and over , Aorta, Thoracic/physiopathology , Cardiovascular Diseases/physiopathology , Female , Follow-Up Studies , Humans , Male , Prospective Studies , Reproducibility of Results
3.
Catheter Cardiovasc Interv ; 96(3): E348-E354, 2020 09 01.
Article in English | MEDLINE | ID: mdl-31696656

ABSTRACT

OBJECTIVES: To assess the safety and efficacy of first-line transcatheter aortic valve implantation (TAVI) in patients presenting with acute decompensated aortic stenosis (ADAS). BACKGROUND: ADAS is common and is often treated medically or using balloon aortic valvuloplasty in the first instance. This temporizing measure results in suboptimal outcomes. In the current era, TAVI provides an alternative option. METHODS: Consecutive patients who had either a TAVI for ADAS or electively were included in the study. The primary outcome was procedural and 30-day mortality and hospital length of stay (LOS). Secondary outcomes included 1-year mortality and procedural complications. RESULTS: Of note, 893 patients (mean age 83 ± 7, 50.5% male) underwent TAVI (19% ADAS, 81% elective). ADAS patients were more unwell with worse echocardiographic parameters than elective patients. ADAS patients of 55.9% were known to have significant aortic stenosis prior to their decompensation. Procedural mortality was not different between the ADAS and elective cohorts (1.2 vs. 0.7%; p = .62). The ADAS cohort had a higher 30-day mortality (5.3 vs. 1.1%; p = .002) and longer LOS (31.9 ± 20.7 days vs. 6.1 ± 6.5 days; p < .001). Multivariate analysis identified acute kidney injury and ADAS as significant predictors of 30-day mortality. CONCLUSIONS: TAVI for ADAS is safe and effective with procedural outcomes similar to elective patients. However, compared to elective patients, they have worse physiological baseline features, poorer prognosis at 30 days, and longer hospital admissions. Majority of patients who presented with ADAS were known to have AS prior to admission.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Feasibility Studies , Female , Hemodynamics , Humans , Length of Stay , London , Male , Postoperative Complications/etiology , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome