Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Mech Behav Biomed Mater ; 153: 106494, 2024 May.
Article in English | MEDLINE | ID: mdl-38507995

ABSTRACT

Collagen fiber arrangement is decisive for constitutive description of anisotropic mechanical response of arterial wall. In this study, their orientation in human common carotid artery was investigated using polarized light microscopy and an automated algorithm giving more than 4·106 fiber angles per slice. In total 113 slices acquired from 18 arteries taken from 14 cadavers were used for fiber orientation in the circumferential-axial plane. All histograms were approximated with unimodal von Mises distribution to evaluate dominant direction of fibers and their concentration parameter. 10 specimens were analyzed also in circumferential-radial and axial-radial planes (2-4 slices per specimen in each plane); the portion of radially oriented fibers was found insignificant. In the circumferential-axial plane, most specimens showed a pronounced unimodal distribution with angle to circumferential direction µ = 0.7° ± 9.4° and concentration parameter b = 3.4 ± 1.9. Suitability of the unimodal fit was confirmed by high values of coefficient of determination (mean R2 = 0.97, median R2 = 0.99). Differences between media and adventitia layers were not found statistically significant. The results are directly applicable as structural parameters in the GOH constitutive model of arterial wall if the postulated two fiber families are unified into one with circumferential orientation.


Subject(s)
Carotid Arteries , Extracellular Matrix , Humans , Carotid Arteries/physiology , Adventitia , Algorithms , Stress, Mechanical , Biomechanical Phenomena , Collagen/chemistry
2.
J Biomech ; 161: 111868, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37976938

ABSTRACT

Most frequently used structure-based constitutive models of arterial wall apply assumptions on two symmetric helical (and dispersed) fibre families which, however, are not well supported with histological findings where two collagen fibre families are seldom found. Moreover, bimodal distributions of fibre directions may originate also from their waviness combined with ignoring differences between local and global fibre orientations. In contrast, if the model parameters are identified without histological information on collagen fibre directions, the resulting mean angles of both fibre families are close to ±45°, which contradicts nearly all histologic findings. The presented study exploited automated polarized light microscopy for detection of collagen fibre directions in porcine aorta under different biaxial extensions and approximated the resulting histograms with unimodal and bimodal von Mises distributions. Their comparison showed dominantly circumferential orientation of collagen fibres. Their concentration parameter for unimodal distributions increased with circumferential load, no matter if acting uniaxially or equibiaxially. For bimodal distributions, the angle between both dominant fibre directions (chosen as measure of fibre alignment) decreased similarly for both uniaxial and equibiaxial loads. These results indicate the existence of a single family of wavy circumferential collagen fibres in all layers of the aortic wall. Bimodal distributions of fibre directions presented sometimes in literature may come rather from waviness of circumferentially arranged fibres than from two symmetric families of helical fibres. To obtain a final evidence, the fibre orientation should be analysed together with their waviness.


Subject(s)
Arteries , Collagen , Swine , Animals , Biomechanical Phenomena , Aorta , Extracellular Matrix , Stress, Mechanical
3.
J Mech Behav Biomed Mater ; 138: 105615, 2023 02.
Article in English | MEDLINE | ID: mdl-36512975

ABSTRACT

The study compares stresses and strains in the aortic wall derived using different constitutive models for various stress-strain conditions. Structure-based constitutive models with two fibre families with (GOH) and without (HGO) dispersion of collagen fibres are compared. The constitutive models were fitted to data from equibiaxial tension tests of two separated layers of the porcine aortic wall. The initial fit was evaluated with unrestricted parameters and subsequently, the mean angles of the fibre families and the angular dispersion were fixed to the values obtained from histology. Surprisingly, none of the tested models was capable to provide a good quality fit with histologically obtained structural parameters. Fitting the HGO model to experimental data resulted in two fibre families under angles close to ±45°, while the GOH model resulted in a nearly isotropic fibre distribution. These results indicate that both of these models suffer from the absence of isotropic strain stiffening. After having modified both models with corresponding additional members based on the Yeoh model of matrix, we obtained a perfect fit to the measured data while keeping the structural histology-based parameters. Finally, significant differences in compliance and resulting stresses and strains between different models are shown by means of simulations of uniaxial tension test, equibiaxial tension tests and inflation of the aorta.


Subject(s)
Aorta , Models, Biological , Swine , Animals , Stress, Mechanical , Biomechanical Phenomena
4.
Biomed Res Int ; 2021: 6879765, 2021.
Article in English | MEDLINE | ID: mdl-34877357

ABSTRACT

A novel method for semiautomated assessment of directions of collagen fibers in soft tissues using histological image analysis is presented. It is based on multiple rotated images obtained via polarized light microscopy without any additional components, i.e., with just two polarizers being either perpendicular or nonperpendicular (rotated). This arrangement breaks the limitation of 90° periodicity of polarized light intensity and evaluates the in-plane fiber orientation over the whole 180° range accurately and quickly. After having verified the method, we used histological specimens of porcine Achilles tendon and aorta to validate the proposed algorithm and to lower the number of rotated images needed for evaluation. Our algorithm is capable to analyze 5·105 pixels in one micrograph in a few seconds and is thus a powerful and cheap tool promising a broad application in detection of collagen fiber distribution in soft tissues.


Subject(s)
Collagen/metabolism , Achilles Tendon/metabolism , Algorithms , Animals , Extracellular Matrix/metabolism , Image Processing, Computer-Assisted/methods , Microscopy/methods , Microscopy, Polarization/methods , Optical Imaging/methods , Swine
5.
PLoS One ; 15(9): e0239447, 2020.
Article in English | MEDLINE | ID: mdl-32991605

ABSTRACT

The paper deals with the impact of chosen geometric and material factors on maximal stresses in carotid atherosclerotic plaque calculated using patient-specific finite element models. These stresses are believed to be decisive for the plaque vulnerability but all applied models suffer from inaccuracy of input data, especially when obtained in vivo only. One hundred computational models based on ex vivo MRI are used to investigate the impact of wall thickness, MRI slice thickness, lipid core and fibrous tissue stiffness, and media anisotropy on the calculated peak plaque and peak cap stresses. The investigated factors are taken as continuous in the range based on published experimental results, only the impact of anisotropy is evaluated by comparison with a corresponding isotropic model. Design of Experiment concept is applied to assess the statistical significance of these investigated factors representing uncertainties in the input data of the model. The results show that consideration of realistic properties of arterial wall in the model is decisive for the stress evaluation; assignment of properties of fibrous tissue even to media and adventitia layers as done in some studies may induce up to eightfold overestimation of peak stress. The impact of MRI slice thickness may play a key role when local thin fibrous cap is present. Anisotropy of media layer is insignificant, and the stiffness of fibrous tissue and lipid core may become significant in some combinations.


Subject(s)
Carotid Arteries/pathology , Mechanical Phenomena , Patient-Specific Modeling , Plaque, Atherosclerotic/pathology , Biomechanical Phenomena , Carotid Arteries/diagnostic imaging , Finite Element Analysis , Humans , Magnetic Resonance Imaging , Models, Cardiovascular , Plaque, Atherosclerotic/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...