Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Publication year range
1.
Phys Med Biol ; 62(12): 5076-5097, 2017 Jun 21.
Article in English | MEDLINE | ID: mdl-28452337

ABSTRACT

In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularization framework and the kernel density estimation method. We obtain simple, closed-form analytical formulae for time resolution. The proposed method is validated using signals registered by means of the single detection unit of the J-PET tomograph built from a 30 cm long plastic scintillator strip. It is shown that the experimental and theoretical results obtained for the J-PET scanner equipped with vacuum tube photomultipliers are consistent.


Subject(s)
Positron-Emission Tomography/instrumentation , Scintillation Counting/instrumentation , Equipment Design , Humans , Plastics , Time Factors
2.
Article in English | MEDLINE | ID: mdl-27547122

ABSTRACT

We present a study of the application of the Jagiellonian positron emission tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the [Formula: see text] decays with angular and energy resolution equal to [Formula: see text] and [Formula: see text], respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pile-ups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities.

3.
Phys Med Biol ; 61(5): 2025-47, 2016 Mar 07.
Article in English | MEDLINE | ID: mdl-26895187

ABSTRACT

Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the [Formula: see text] configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the [Formula: see text] matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of [Formula: see text]0.170 ns for 15 cm axial field-of-view (AFOV) and [Formula: see text]0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.


Subject(s)
Photons , Plastics/radiation effects , Positron-Emission Tomography/methods , Scintillation Counting/methods , Scintillation Counting/instrumentation
4.
Phys Rev Lett ; 106(24): 242302, 2011 Jun 17.
Article in English | MEDLINE | ID: mdl-21770567

ABSTRACT

We report on an exclusive and kinematically complete high-statistics measurement of the basic double-pionic fusion reaction pn→dπ(0)π(0) over the full energy region of the ABC effect, a pronounced low-mass enhancement in the ππ-invariant mass spectrum. The measurements, which cover also the transition region to the conventional t-channel ΔΔ process, were performed with the upgraded WASA detector setup at COSY. The data reveal the Abashian-Booth-Crowe effect to be uniquely correlated with a Lorentzian energy dependence in the integral cross section. The observables are consistent with a narrow resonance with m=2.37 GeV, Γ≈70 MeV and I(J(P))=0(3(+)) in both pn and ΔΔ systems. Necessary further tests of the resonance interpretation are discussed.

5.
J Reprod Immunol ; 71(2): 126-31, 2006 Oct.
Article in English | MEDLINE | ID: mdl-16870264

ABSTRACT

IFN-tau is a signaling protein secreted by the bovine conceptus during the peri-implantation period and responsible for pregnancy recognition. Its main role is the prevention of pulsatile release of luteolytic PGF2alpha, but it also exerts immunomodulatory activities characteristic for other type I interferons. The aim of the study was to examine the effect of IFN-tau on the proliferation and distribution of peripheral blood lymphocyte subsets during one-way mixed lymphocyte reaction (MLR) in cows and heifers. IFN-tau inhibited the proliferative response of lymphocytes in MLR both in cows and heifers in a dose-dependent manner, but cow lymphocytes were less susceptible than those ones from heifers. It was also showed that IFN-tau differentially changed lymphocyte subsets distribution in MLR in cows and heifers. In cows, the relative percentage of CD8(+) cells after MRL in the presence of IFN-tau was significantly lower than in heifers. Differential effect of rIFN-tau on proliferation and lymphocyte subsets distribution in a one-way MRL in cows and heifers indicated that the age of the mother is an important factor in immunomodulatory effect towards developing bovine embryo.


Subject(s)
Interferon Type I/physiology , Lymphocyte Subsets/cytology , Pregnancy Proteins/physiology , Analysis of Variance , Animals , CD4-Positive T-Lymphocytes/cytology , CD4-Positive T-Lymphocytes/metabolism , Cattle , Cell Proliferation , Female , Lymphocyte Culture Test, Mixed , Male , Pregnancy
6.
Stat Med ; 15(10): 1033-47, 1996 May 30.
Article in English | MEDLINE | ID: mdl-8783440

ABSTRACT

In this paper we give an informal introduction to a robust method for survival analysis which is based on a modification of the usual partial likelihood estimator (PLE). Large sample results lead us to expect reduced bias for this robust estimator compared with the PLE whenever there are even slight violations of the model. In this paper we investigate three types of violation: (a) varying dependency structure of survival time and covariates over the sample; (b) omission of influential covariates, and (c) errors in the covariates. The simulations presented support the above expectation. Analyses of data sets from cancer epidemiology and from a clinical trial in lung cancer illustrate that a better fit and additional insights may be gained using robust estimators.


Subject(s)
Proportional Hazards Models , Survival Analysis , Algorithms , Bias , Computer Simulation , Humans , Likelihood Functions , Lung Neoplasms/mortality , Models, Statistical , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...