1.
EJNMMI Res ; 8(1): 11, 2018 Feb 05.
Article in English | MEDLINE | ID: mdl-29404708

ABSTRACT

BACKGROUND: 15O-Water positron emission tomography (PET) enables functional imaging of the auditory system during stimulation via a promontory electrode or cochlear implant, which is not possible using functional magnetic resonance imaging (fMRI). Although PET has been introduced in this context decades ago, its feasibility when performed during general anesthesia has not yet been explored. However, due to a shift to earlier (and bilateral) auditory implantation, the need to study children during general anesthesia appeared, since they are not able to cooperate during scanning. Therefore, we evaluated retrospectively results of individual SPM (statistical parametric mapping) analysis of 15O-water PET in 17 children studied during general anesthesia and compared them to those in 9 adults studied while awake. Specifically, the influence of scan duration, smoothing filter kernel employed during preprocessing, and cut-off value used for statistical inferences were evaluated. Frequencies, peak heights, and extents of activations in auditory and extra-auditory brain regions (AR and eAR) were registered. RESULTS: It was possible to demonstrate activations in auditory brain regions during general anesthesia; however, the frequency and markedness of positive findings were dependent on some of the abovementioned influence factors. Scan duration (60 vs. 90 s) had no significant influence on peak height of auditory cortex activations. To achieve a similar frequency and extent of AR activations during general anesthesia compared to waking state, a lower cut-off for statistical inferences (p < 0.05 or p < 0.01 vs. p < 0.001) had to be applied. However, this lower cut-off was frequently associated with unexpected, "artificial" activations in eAR. These activations in eAR could be slightly reduced by the use of a stronger smoothing filter kernel during preprocessing of the data (e.g., [30 mm]3). CONCLUSIONS: Our data indicate that it is feasible to detect auditory cortex activations in 15O-water PET during general anesthesia. Combined with the improved signal to noise ratios of modern PET scanners, this suggests reasonable prospects for further evaluation of the method for clinical use in auditory implant users. Adapted parameters for data analysis seem to be helpful to improve the proportion of signals in AR versus eAR.

2.
J Clin Monit Comput ; 18(4): 231-40, 2004 Aug.
Article in English | MEDLINE | ID: mdl-15779834

ABSTRACT

OBJECTIVE: The aim of this study was to compare the EEG parameter Narcotrend Index with the spectral and entropy-based EEG parameters median frequency, 95% spectral edge frequency, burst-compensated 95% spectral edge frequency, spectral entropy, amplitude entropy, and approximate entropy with regard to their ability to describe cerebral anaesthetic drug effects during induction of propofol-remifentanil anaesthesia. METHODS: Three induction schemes were studied with 10 patients each receiving 2 mg propofol/kg/60s (group 1), 4 mg/kg/120s (group 2), and 4 mg/kg/240s (group 3). The EEG was recorded with the EEG monitor Narcotrend. To analyse the relation between drug effect and EEG parameters, Spearman rank correlation of the different EEG parameters with the calculated propofol effect-site concentration was computed. RESULTS: In all groups Narcotrend Index showed the highest correlation with the propofol effect-site concentration and the lowest variability of individual correlation values. Furthermore, only the Narcotrend Index showed a monophasic behaviour over the entire time period analysed. In the group of entropy parameters approximate entropy yielded the best results. Among the spectral parameters the burst-compensated 95% spectral edge frequency had the highest correlation with the propofol effect-site concentration. It was markedly higher than for the standard spectral edge frequency. The correlations of median frequency and amplitude entropy with propofol effect-site concentration were the lowest. CONCLUSIONS. Changes in the propofol effect-site concentration during induction of anaesthesia were best described by the multivariate Narcotrend Index compared to conventional spectral EEG parameters and different entropy measures.


Subject(s)
Anesthesia, General/methods , Anesthetics, Intravenous/pharmacology , Electroencephalography , Piperidines/pharmacology , Propofol/pharmacology , Adolescent , Adult , Child , Data Collection , Entropy , Female , Humans , Male , Middle Aged , Monitoring, Physiologic , Multivariate Analysis , Remifentanil
SELECTION OF CITATIONS