Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
1.
Acta Physiol (Oxf) ; 240(5): e14140, 2024 May.
Article in English | MEDLINE | ID: mdl-38546351

ABSTRACT

AIM: Inflammation and calcification are hallmarks in the development of aortic valve stenosis (AVS). Ceramides mediate inflammation and calcification in the vascular tissue. The highly abundant d18:1,16:0 ceramide (C16) has been linked to increased cardiovascular mortality and obesity. In this study, we investigate the role of ceramide synthase 5 (CerS5), a critical enzyme for C16 ceramide synthesis, in the development of AVS, particularly in conjunction with a high-fat/high-cholesterol diet (Western diet, WD). METHODS: We used wild-type (WT) and CerS5-/- mice on WD or normal chow in a wire injury model. We measured the peak velocity to determine AVS development and performed histological analysis of the aortic valve area, immune cell infiltration (CD68 staining), and calcification (von Kossa). In vitro experiments involved measuring the calcification of human aortic valvular interstitial cells (VICs) and evaluating cytokine release from THP-1 cells, a human leukemia monocytic-like cell line, following CerS5 knockdown. RESULTS: CerS5-/- mice showed a reduced peak velocity compared to WT only in the experiment with WD. Likewise, we observed reduced immune cell infiltration and calcification in the aortic valve of CerS5-/- mice, but only on WD. In vitro, calcification was reduced after knockdown of CerS5 in VICs, while THP-1 cells exhibited a decreased inflammatory response following CerS5 knockdown. CONCLUSION: We conclude that CerS5 is an important mediator for the development of AVS in mice on WD and regulates critical pathophysiological hallmarks of AVS formation. CerS5 is therefore an interesting target for pharmacological therapy and merits further investigation.

2.
Int J Cardiol ; 405: 131939, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38458388

ABSTRACT

BACKGROUND: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device. METHODS: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed. RESULTS: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118). CONCLUSION: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Septal Occluder Device , Humans , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Male , Female , Aged , Retrospective Studies , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Aged, 80 and over , Registries , Treatment Outcome , Echocardiography, Transesophageal/methods , Contrast Media/administration & dosage , Follow-Up Studies
3.
Clin Res Cardiol ; 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38358420

ABSTRACT

INTRODUCTION: Cryoballoon (CB) ablation has become a popular method for pulmonary vein isolation (PVI) in atrial fibrillation (AF) treatment. This study aimed to compare the intraprocedural ablation characteristics of two cryoballoons, Arctic Front Advance Pro™ (AFA-Pro, Medtronic) and POLARx™ (Boston Scientific). METHODS AND RESULTS: In this retrospective single-center study, 230 symptomatic paroxysmal or persistent AF patients underwent CB ablation with either AFA-Pro or POLARx. Propensity-score matching resulted in two cohorts of 114 patients each. Baseline and procedural characteristics were comparable between both CBs. POLARx achieved lower minimal temperatures (e.g., left superior pulmonary vein, LSPV: AFA-Pro - 49.0 °C vs. POLARx - 59.5 °C) and lower temperatures at time-to-isolation (TTI). Additionally, POLARx reached lower temperatures faster, as evidenced by lower temperatures after 40 and 60 s, and a larger mean temperature change between 20 and 40 s. POLARx also had a greater area under the curve below 0 °C and a longer thawing phase. Both CBs achieved comparable high rates of final PV-isolation. TTI, minimal esophagus temperature, and first-pass isolation rates were similar between groups. Periprocedural complications, including phrenic nerve injuries, were comparable. Troponin levels in the left atrium were elevated with both systems. Values and change in troponin were numerically higher in the POLARx group (delta troponin: AFA-Pro 36.3 (26.4, 125.4) ng/L vs. POLARx 104.9 (49.5, 122.2) ng/L), p = 0.077). CONCLUSION: AFA-Pro and POLARx are both highly effective and safe CB systems for PVI. POLARx exhibited significant faster and lower freezing characteristics, and numerically higher troponin levels might indicate greater myocardial injury. However, these differences did not translate into improved performance, procedural efficiency, or safety.

4.
Clin Res Cardiol ; 2023 Nov 03.
Article in English | MEDLINE | ID: mdl-37921923

ABSTRACT

BACKGROUND AND OBJECTIVES: Long-term oral anticoagulation (OAC) following successful catheter ablation of atrial fibrillation (AF) remains controversial. Prospective data are missing. The ODIn-AF study aimed to evaluate the effect of OAC on the incidence of silent cerebral embolic events and clinically relevant cardioembolic events in patients at intermediate to high risk for embolic events, free from AF after pulmonary vein isolation (PVI). METHODS: This prospective, randomized, multicenter, open-label, blinded endpoint interventional trial enrolled patients who were scheduled for PVI to treat paroxysmal or persistent AF. Six months after PVI, AF-free patients were randomized to receive either continued OAC with dabigatran or no OAC. The primary endpoint was the incidence of new silent micro- and macro-embolic lesions detected on brain MRI at 12 months of follow-up compared to baseline. Safety analysis included bleedings, clinically evident cardioembolic, and serious adverse events (SAE). RESULTS: Between 2015 and 2021, 200 patients were randomized into 2 study arms (on OAC: n = 99, off OAC: n = 101). There was no significant difference in the occurrence of new cerebral microlesions between the on OAC and off OAC arm [2 (2%) versus 0 (0%); P = 0.1517] after 12 months. MRI showed no new macro-embolic lesion, no clinical apparent strokes were present in both groups. SAE were more frequent in the OAC arm [on OAC n = 34 (31.8%), off OAC n = 18 (19.4%); P = 0.0460]; bleedings did not differ. CONCLUSION: Discontinuation of OAC after successful PVI was not found to be associated with an elevated risk of cerebral embolic events compared with continued OAC after a follow-up of 12 months.

5.
Echocardiography ; 40(11): 1227-1236, 2023 11.
Article in English | MEDLINE | ID: mdl-37788148

ABSTRACT

OBJECTIVE: To evaluate the role of the CT-derived angle between the intra-atrial septum (IAS) and the left atrial appendage (LAA) on procedural complexity and clinical outcomes in left atrial appendage occlusion (LAAO) procedures. BACKGROUND: Given the broad variations in anatomy, LAAO remains one of the most challenging interventional procedures in structural heart disease. In recent years, preprocedural cardiac tomography (CT) has evolved as a valuable tool; however, prediction of procedural complexity remains cumbersome. METHODS: We retrospectively analyzed 47 patients that underwent LAAO at our center in whom pre-procedural cardiac CT-scans were available. Among other baseline parameters, we measured the angle between the LAA ostium and the preferred transseptal puncture site at the IAS. We compared patients with an angle above and below the median regarding procedural characteristics and procedural outcome. RESULTS: The median angle between the LAA and the IAS was 127.3° (IQR: 120.9-141.3). LAAO took longer in patients with a measured angle below the median (55.0 ± 22.7 min vs. 41.3 ± 17.5 min; p = .04), resulting in longer radiation times (13.0 ± 5.3 min vs. 9.8 ± 5.7 min; p = .04) and more contrast use (61.1 ± 47.5 mL vs. 33.6 ± 24.7 mL; p = .05). Moreover, the necessity for a sheath exchange was significantly higher (30.4% vs. 4.2%, p = .02) and device repositioning or device resizing trended to be more frequent (26.1% vs. 8.3%; p = .1 and 21.7% vs. 8.3%; p = .2). There were no differences in procedural outcome, device-position and peri-device leak (PDL). CONCLUSIONS: The angle between the transseptal puncture site and the LAA ostium may serve as a predictor for more demanding LAAO interventions. In our study a steeper angle led to a prolonged procedure resulting in higher doses of contrast and radiation, but was not associated with a worse procedural outcome.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Humans , Treatment Outcome , Echocardiography, Transesophageal/methods , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Retrospective Studies , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Cardiac Catheterization/methods , Tomography , Tomography, X-Ray Computed
6.
BMC Cardiovasc Disord ; 23(1): 513, 2023 10 21.
Article in English | MEDLINE | ID: mdl-37864159

ABSTRACT

PURPOSE: Due to recent advances in diagnosis and treatment, the number of adults with congenital heart disease (ACHD) has substantially increased. This achievement is mitigated by rhythm disorders. Here, we sought to determine alterations in heart rate variability (HRV) and their prognostic value in ACHD. METHODS: Ninety seven ACHD patients (39.2 ± 14.1 years, 51.5% female) and 19 controls (39.7 ± 15.0 years, 47.4% female) underwent 24-h Holter monitoring. RESULTS: As compared to controls, ACHD patients offered a significantly higher burden of premature ventricular contractions (p = 0.02) and decreased HRV indices (natural logarithmic transformation of very low frequency (lnVLF): 7.46 ± 0.76 ms2 vs. 7.91 ± 0.92ms2, p = 0.03; natural logarithmic transformation of low frequency (lnLF): 6.39 ± 0.95ms2 vs. 7.01 ± 1.07ms2, p = 0.01; natural logarithmic transformation of the ratio of low to high frequency spectra (lnLF/HF): 0.81 ± 0.74 vs. 1.17 ± 0.51, p = 0.04). No differences in HRV measures were observed across ACHD lesion groups. NT-proBNP levels were significantly related to both time and frequency domain indices (natural logarithmic transformation of the standard deviation of NN intervals (lnSDNN): Spearman´s rho = -0.32, p = 0.001; natural logarithmic transformation of the standard deviation of the average NN intervals for each 5-min segment of a 24-h Holter monitoring (lnSDANN): Spearman´s rho: -0.33, p = 0.001; natural logarithmic transformation of the total power (lnTP): Spearman´s rho: -0.25, p = 0.01; lnVLF: Spearman´s rho: -0.33, p = 0.001; lnLF: Spearman´s rho: -0.35, p < 0.001; lnLF/HF: Spearman´s rho: -0.34, p = 0.001). After a mean follow-up of 3.9 ± 0.7 years, 8 patients died and 3 patients survived sudden cardiac death (SCD). Several HRV parameters were significantly higher in event-free ACHD patients than in those who died or survived SCD (natural logarithmic transformation of the average of the standard deviations of NN intervals for each 5-min segment of a 24-h Holter monitoring (lnASDNN): p = 0.04; lnPNN30: p = 0.04; lnVFL: p = 0.03; lnLF: p < 0.01). On univariate Cox regression analysis, the time domain indices lnSDNN, lnASDNN and lnPNN30, as well as the frequency domain parameters lnTP, lnVLF and lnLF were associated with death and survived cardiac arrest. CONCLUSION: ACHD is accompanied by HRV impairment that carries prognostic implications on ACHD mortality and survived SCD.


Subject(s)
Autonomic Nervous System Diseases , Heart Defects, Congenital , Humans , Adult , Female , Male , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnosis , Heart , Autonomic Nervous System , Electrocardiography, Ambulatory , Death, Sudden, Cardiac , Heart Rate/physiology
7.
J Am Heart Assoc ; 12(18): e030615, 2023 09 19.
Article in English | MEDLINE | ID: mdl-37681569

ABSTRACT

Background Data on the use of the wearable cardioverter-defibrillator (WCD) among patients with myocarditis remain sparse. Consequently, evidence for guideline recommendations in this patient population is lacking. Methods and Results In total, 1596 consecutive patients were included in a multicenter registry from 8 European centers, with 124 patients (8%) having received the WCD due to myocarditis and reduced left ventricular ejection fraction or prior ventricular tachyarrhythmia. The mean age was 51.6±16.3 years, with 74% being male. Patients were discharged after index hospitalization on heart failure medication: Angiotensin-converting enzyme inhibitors (62.5%), angiotensin-receptor-neprilysin inhibitor (22.9%), aldosterone-antagonists (51%), or beta blockers (91.4%). The initial median left ventricular ejection fraction was 30% (22%-45%) and increased to 48% (39%-55%) over long-term follow-up (P<0.001). The median BNP (brain natriuretic peptide) level at baseline was 1702 pg/mL (565-3748) and decreased to 188 pg/mL (26-348) over long-term follow-up (P=0.022). The mean wear time was 79.7±52.1 days and 21.0±4.9 hours per day. Arrhythmic event rates documented by the WCD were 9.7% for nonsustained ventricular tachycardia, 6.5% for sustained ventricular tachycardia, and 0% for ventricular fibrillation. Subsequently, 2.4% of patients experienced an appropriate WCD shock. The rate of inappropriate WCD shocks was 0.8%. All 3 patients with appropriate WCD shock had experienced ventricular tachycardia/ventricular fibrillation before WCD prescription, with only 1 patient showing a left ventricular ejection fraction <35%. Conclusions Patients with myocarditis and risk for occurrence of ventricular tachyarrhythmia may benefit from WCD use. Prior ventricular arrhythmia might appear as a better risk predictor than a reduced left ventricular ejection fraction <35% in this population.


Subject(s)
Myocarditis , Tachycardia, Ventricular , Wearable Electronic Devices , Humans , Male , Adult , Middle Aged , Aged , Female , Stroke Volume , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/therapy , Ventricular Function, Left , Myocarditis/complications , Myocarditis/therapy , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Defibrillators
9.
Eur Heart J ; 44(27): 2458-2469, 2023 Jul 14.
Article in English | MEDLINE | ID: mdl-37062040

ABSTRACT

AIMS: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. METHODS AND RESULTS: This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. CONCLUSION: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophageal Fistula , Humans , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Treatment Outcome , Incidence , Risk Factors , Esophageal Fistula/epidemiology , Esophageal Fistula/etiology , Esophageal Fistula/diagnosis , Prognosis , Catheter Ablation/adverse effects , Catheter Ablation/methods
10.
Eur J Clin Invest ; 53(7): e13977, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36852491

ABSTRACT

BACKGROUND: Wearable cardioverter defibrillators (WCD) are used as a 'bridging' technology in patients, who are temporarily at high risk for sudden cardiac death (SCD). Several factors should be taken into consideration, for example patient selection, compliance and optimal drug treatment, when WCD is prescribed. We aimed to present real-world data from seven centres from Germany and Switzerland according to age differences regarding the outcome, prognosis, WCD data and compliance. MATERIALS AND METHODS: Between 04/2012 and 03/2021, 1105 patients were included in this registry. Outcome data according to age differences (old ≥45 years compared to young <45 years) were analysed. At young age, WCDs were more often prescribed due to congenital heart disease and myocarditis. On the other hand, ischaemic cardiomyopathy (ICM) was more present in older patients. Wear days of WCD were similar between both groups (p = .115). In addition, during the WCD use, documented arrhythmic life-threatening events were comparable [sustained ventricular tachycardia: 5.8% vs. 7.7%, ventricular fibrillation (VF) .5% vs. .6%] and consequently the rate of appropriate shocks was similar between both groups. Left ventricular ejection fraction improvement was documented over follow-up with a better improvement in younger patients as compared to older patients (77% vs. 63%, p = .002). In addition, at baseline, the rate of atrial fibrillation was significantly higher in the older age group (23% vs. 8%; p = .001). The rate of permanent cardiac implantable electronic device implantation (CiED) was lower in the younger group (25% vs. 36%, p = .05). The compliance rate defined as wearing WCD at least 20 h per day was significantly lower in young patients compared to old patients (68.9% vs. 80.9%, p < .001). During the follow-up, no significant difference regarding all-cause mortality or arrhythmic death was documented in both groups. A low compliance rate of wearing WCD is predicted by young patients and patients suffering from non-ischaemic cardiomyopathies. CONCLUSION: Although the compliance rate in different age groups is high, the average wear hours tended to be lower in young patients compared to older patients. The clinical events were similar in younger patients compared to older patients.


Subject(s)
Atrial Fibrillation , Myocardial Ischemia , Wearable Electronic Devices , Humans , Aged , Middle Aged , Stroke Volume , Ventricular Function, Left , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Myocardial Ischemia/therapy , Myocardial Ischemia/complications , Registries , Atrial Fibrillation/complications , Defibrillators/adverse effects , Retrospective Studies
12.
Int J Cardiol Heart Vasc ; 44: 101168, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36620202

ABSTRACT

Aims: Na+/Ca2+ exchanger (NCX) upregulation in cardiac diseases like heart failure promotes as an independent proarrhythmic factor early and delayed afterdepolarizations (EADs/DADs) on the single cell level. Consequently, NCX inhibition protects against EADs and DADs in isolated cardiomyocytes. We here investigate, whether these promising cellular in vitro findings likewise apply to an in vivo setup. Methods/Results: Programmed ventricular stimulation (PVS) and isoproterenol were applied to a murine heterozygous NCX-knockout model (KO) to investigate ventricular arrhythmia initiation and perpetuation compared to wild-type (WT). KO displayed a reduced susceptibility towards isoproterenol-induced premature ventricular complexes. During PVS, initiation of single or double ectopic beats was similar between KO and WT. But strikingly, perpetuation of ventricular tachycardia (VT) was significantly increased in KO (animals with VT - KO: 82 %; WT: 47 %; p = 0.0122 / median number of VTs - KO: 4.5 (1.0, 6.25); WT: 0.0 (0.0, 4.0); p = 0.0039). The median VT duration was prolonged in KO (in s; KO: 0.38 (0.19, 0.96); WT: 0.0 (0.0, 0.60); p = 0.0239). The ventricular refractory period (VRP) was shortened in KO (in ms; KO: 15.1 ± 0.7; WT: 18.7 ± 0.7; p = 0.0013). Conclusions: Not the initiation, but the perpetuation of provoked whole-heart in vivo ventricular arrhythmia was increased in KO. As a potential mechanism, we found a significantly reduced VRP, which may promote perpetuation of reentrant ventricular arrhythmia. On a translational perspective, the antiarrhythmic concept of therapeutic NCX inhibition seems to be ambivalent by protecting from initiating afterdepolarizations but favoring arrhythmia perpetuation in vivo at least in a murine model.

13.
Nat Commun ; 13(1): 1765, 2022 04 01.
Article in English | MEDLINE | ID: mdl-35365606

ABSTRACT

Gq proteins are universally important for signal transduction in mammalian cells. The underlying kinetics and transformation from extracellular stimuli into intracellular signaling, however could not be investigated in detail so far. Here we present the human Neuropsin (hOPN5) for specific and repetitive manipulation of Gq signaling in vitro and in vivo with high spatio-temporal resolution. Properties and G protein specificity of hOPN5 are characterized by UV light induced IP3 generation, Ca2+ transients and inhibition of GIRK channel activity in HEK cells. In adult hearts from a transgenic animal model, light increases the spontaneous beating rate. In addition, we demonstrate light induced contractions in the small intestine, which are not detectable after pharmacological Gq protein block. All-optical high-throughput screening for TRPC6 inhibitors is more specific and sensitive than conventional pharmacological screening. Thus, we demonstrate specific Gq signaling of hOPN5 and unveil its potential for optogenetic applications.


Subject(s)
Optogenetics , Signal Transduction , Animals , Humans , Light , Mammals , Signal Transduction/physiology , TRPC6 Cation Channel
14.
Echocardiography ; 39(1): 65-73, 2022 01.
Article in English | MEDLINE | ID: mdl-34921426

ABSTRACT

OBJECTIVE: To investigate the rate and clinical impact of a persisting iatrogenic atrial septal defect (iASD) after percutaneous left atrial appendage occlusion (LAAO). BACKGROUND: Percutaneous LAAO is an alternative to oral anticoagulation (OAC) for the prevention of ischemic stroke and systemic embolism in patients with atrial fibrillation (AF). Data regarding incidence and persistence of iASD after LAAO procedures and its clinical relevance is scarce. METHODS: We retrospectively analyzed 144 patients that underwent LAAO at our center between 2009 and 2020 who had at least one follow-up including transesophageal echocardiography (TEE). Baseline clinical, procedural data and echocardiographic characteristics in patients with and without evidence of an iASD were compared. We furthermore determined the rate of iASD persistence over time and evaluated outcomes of patients with and without spontaneous iASD closure. RESULTS: After a median of 92 days (IQR 75-108 days) after LAAO, 50 patients (50/144, 34.7%) showed evidence of an iASD. Patients with iASD had higher CHADS-VASc-scores (4.9±1.5 vs 4.2±1.2, p = 0.03), larger left atrial volumes (80.5±30.5 ml vs 67.1±19.7 ml, p = 0.01) and were more likely to have relevant mitral regurgitation (≥° II) (46.0% vs 12.3%, p = 0.001). LAAO procedures took longer (50.1±24.3 vs 41.1±17.8 min, p = 0.06) in patients with a persisting iASD. Furthermore, larger device sizes were implanted (24.3±3.4 mm vs 22.1±2.8 mm, p = 0.03). The presence of an iASD had no impact on RV dysfunction, thromboembolism or mortality. Spontaneous closure of an iASD was documented in 52.0% (26/50). Hereby, similar risk factors were identified for the persistence of an iASD in follow-up.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Heart Septal Defects, Atrial , Stroke , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/complications , Cardiac Catheterization/methods , Echocardiography, Transesophageal , Heart Septal Defects, Atrial/epidemiology , Heart Septal Defects, Atrial/surgery , Humans , Iatrogenic Disease/epidemiology , Incidence , Retrospective Studies , Treatment Outcome
15.
Transl Psychiatry ; 11(1): 164, 2021 03 15.
Article in English | MEDLINE | ID: mdl-33723234

ABSTRACT

Psychosocial stress is one of the main environmental factors contributing to the development of psychiatric disorders. In humans and rodents, chronic stress is associated with elevated inflammatory responses, indicated by increased numbers of circulating myeloid cells and activation of microglia, the brain-resident immune cells. The endocannabinoid system (ECS) regulates neuronal and endocrine stress responses via the cannabinoid receptor 1 (CB1). CB1-deficient mice (Cnr1-/-) are highly sensitive to stress, but if this involves altered inflammatory responses is not known. To test this, we exposed Cnr1+/+ and Cnr1-/- mice to chronic social defeat stress (CSDS). Cnr1-/- mice were extremely sensitive to a standard protocol of CSDS, indicated by an increased mortality rate. Therefore, a mild CSDS protocol was established, which still induced a behavioural phenotype in susceptible Cnr1-/- mice. These mice also showed altered glucocorticoid levels after mild CSDS, suggesting dysregulation of the hypothalamic-pituitary-adrenal (HPA) axis. Mild CSDS induced weak myelopoiesis in the periphery, but no recruitment of myeloid cells to the brain. In contrast, mild CSDS altered microglial activation marker expression and morphology in Cnr1-/- mice. These microglial changes correlated with the severity of the behavioural phenotype. Furthermore, microglia of Cnr1-/- mice showed increased expression of Fkbp5, an important regulator of glucocorticoid signalling. Overall, the results confirm that CB1 signalling protects the organism from the physical and emotional harm of social stress and implicate endocannabinoid-mediated modulation of microglia in the development of stress-related pathologies.


Subject(s)
Microglia , Social Defeat , Animals , Mice , Mice, Inbred C57BL , Pituitary-Adrenal System , Receptor, Cannabinoid, CB1/genetics , Receptors, Cannabinoid , Stress, Psychological
16.
Pacing Clin Electrophysiol ; 44(1): 93-100, 2021 01.
Article in English | MEDLINE | ID: mdl-33140439

ABSTRACT

BACKGROUND: Implantable cardioverter defibrillators use low-voltage shock impedance measurements to monitor the lead integrity. However, previous case reports suggest that low-voltage shock impedance measurements may fail to detect insulation breaches that can cause life-threatening electrical short circuits. METHODS AND RESULTS: We report six cases of insulation breaches in transvenous defibrillation leads that were not obvious during standard interrogations and testing of the lead beforehand. In two cases, an electrical short circuit during commanded shock delivery for internal electrical cardioversion resulted in a total damage of the ICD generator. In one of these cases, commanded shock delivery induced ventricular fibrillation, which required external defibrillation. In two cases, a shock due to ventricular tachycardia was aborted as the shock impedance was less than 20 Ω. However, in both cases the tiny residual shock energy terminated the ventricular tachycardia. In contrast, in one case the residual energy of the aborted shock did not end ventricular fibrillation induced at defibrillator threshold testing. In one case, the ICD indicated an error code for a short circuit condition detected during an adequate shock delivery. CONCLUSIONS: This case series illustrates that low-voltage shock impedance measurements can fail to detect insulation breaches. These data suggest that in patients without a contraindication, traditional defibrillator threshold testing or high voltage synchronized shock at the time of device replacement should be considered.


Subject(s)
Defibrillators, Implantable , Electric Countershock/adverse effects , Electric Countershock/instrumentation , Aged , Aged, 80 and over , Electric Impedance , Electrocardiography , Equipment Failure Analysis , Humans , Male , Middle Aged
17.
PLoS One ; 15(3): e0228913, 2020.
Article in English | MEDLINE | ID: mdl-32126091

ABSTRACT

BACKGROUND: Mutations in the human desmin gene (DES) cause autosomal-dominant and -recessive cardiomyopathies, leading to heart failure, arrhythmias, and AV blocks. We analyzed the effects of vascular pressure overload in a patient-mimicking p.R349P desmin knock-in mouse model that harbors the orthologue of the frequent human DES missense mutation p.R350P. METHODS AND RESULTS: Transverse aortic constriction (TAC) was performed on heterozygous (HET) DES-p.R349P mice and wild-type (WT) littermates. Echocardiography demonstrated reduced left ventricular ejection fraction in HET-TAC (WT-sham: 69.5 ± 2.9%, HET-sham: 64.5 ± 4.7%, WT-TAC: 63.5 ± 4.9%, HET-TAC: 55.7 ± 5.4%; p<0.01). Cardiac output was significantly reduced in HET-TAC (WT sham: 13088 ± 2385 µl/min, HET sham: 10391 ± 1349µl/min, WT-TAC: 8097 ± 1903µl/min, HET-TAC: 5793 ± 2517µl/min; p<0.01). Incidence and duration of AV blocks as well as the probability to induce ventricular tachycardias was highest in HET-TAC. We observed reduced mtDNA copy numbers in HET-TAC (WT-sham: 12546 ± 406, HET-sham: 13526 ± 781, WT-TAC: 11155 ± 3315, HET-TAC: 8649 ± 1582; p = 0.025), but no mtDNA deletions. The activity of respiratory chain complexes I and IV showed the greatest reductions in HET-TAC. CONCLUSION: Pressure overload in HET mice aggravated the clinical phenotype of cardiomyopathy and resulted in mitochondrial dysfunction. Preventive avoidance of pressure overload/arterial hypertension in desminopathy patients might represent a crucial therapeutic measure.


Subject(s)
Amino Acid Substitution , Atrioventricular Block/physiopathology , Cardiomyopathies/physiopathology , Desmin/genetics , Animals , Atrioventricular Block/genetics , Cardiomyopathies/genetics , DNA Copy Number Variations , DNA, Mitochondrial/genetics , Disease Models, Animal , Female , Gene Knock-In Techniques , Heterozygote , Humans , Male , Mice , Stroke Volume
19.
Herzschrittmacherther Elektrophysiol ; 30(4): 330-335, 2019 Dec.
Article in German | MEDLINE | ID: mdl-31696309

ABSTRACT

Catheter ablation of cardiac arrhythmias has evolved over the years and has become a cornerstone in the modern treatment of various supraventricular and ventricular arrhythmias. The goal of ablation is to permanently damage myocardium that is critically involved in the individual arrhythmia mechanism. Different catheters and forms of energy are available. Radiofrequency (RF) ablation is most common. Application of an alternating current at the catheter tip induces heating of tissue and, thus, leads to ablation of a targeted arrhythmogenic substrate. High temperatures (>70 °C at the catheter tip and >95 °C within the tissue) bear the risk of coagulum formation and steam pops and should be avoided, which limits power application. The evolution of irrigated RF ablation catheters enables the transfer of more power to the tissue and thereby increases the dimensions of the lesions. Cryoablation represents a valuable alternative. Cooling of tissue to -80 °C causes the intra- and extracellular formation of ice crystals, finally resulting in a dense circumscribed scar. The cryomapping procedure grants improved surveillance of the safety of ablation. Cryoenergy is very popular for pulmonary vein isolation (PVI) using the cryoballoon. In addition to the laser balloon that is established for PVI, ultrasound, microwaves, and stereotactic irradiation complete the arsenal.


Subject(s)
Catheter Ablation , Atrial Fibrillation , Cryosurgery , Humans , Pulmonary Veins
SELECTION OF CITATIONS
SEARCH DETAIL
...