Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 113
Filter
1.
Eur Heart J ; 45(20): 1831-1839, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38740526

ABSTRACT

BACKGROUND AND AIMS: Arrhythmic mitral valve prolapse (AMVP) is linked to life-threatening ventricular arrhythmias (VAs), and young women are considered at high risk. Cases of AMVP in women with malignant VA during pregnancy have emerged, but the arrhythmic risk during pregnancy is unknown. The authors aimed to describe features of women with high-risk AMVP who developed malignant VA during the perinatal period and to assess if pregnancy and the postpartum period were associated with a higher risk of malignant VA. METHODS: This retrospective international multi-centre case series included high-risk women with AMVP who experienced malignant VA and at least one pregnancy. Malignant VA included ventricular fibrillation, sustained ventricular tachycardia, or appropriate shock from an implantable cardioverter defibrillator. The authors compared the incidence of malignant VA in non-pregnant periods and perinatal period; the latter defined as occurring during pregnancy and within 6 months after delivery. RESULTS: The authors included 18 women with AMVP from 11 centres. During 7.5 (interquartile range 5.8-16.6) years of follow-up, 37 malignant VAs occurred, of which 18 were pregnancy related occurring in 13 (72%) unique patients. Pregnancy and 6 months after delivery showed increased incidence rate of malignant VA compared to the non-pregnancy period (univariate incidence rate ratio 2.66, 95% confidence interval 1.23-5.76). CONCLUSIONS: The perinatal period could impose increased risk of malignant VA in women with high-risk AMVP. The data may provide general guidance for pre-conception counselling and for nuanced shared decision-making between patients and clinicians.


Subject(s)
Mitral Valve Prolapse , Pregnancy Complications, Cardiovascular , Humans , Female , Pregnancy , Mitral Valve Prolapse/complications , Mitral Valve Prolapse/epidemiology , Retrospective Studies , Adult , Pregnancy Complications, Cardiovascular/epidemiology , Risk Factors , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/etiology , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Puerperal Disorders/epidemiology , Puerperal Disorders/etiology , Defibrillators, Implantable , Incidence , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/etiology , Postpartum Period
3.
Circ Arrhythm Electrophysiol ; 17(3): e012278, 2024 03.
Article in English | MEDLINE | ID: mdl-38344845

ABSTRACT

BACKGROUND: Electroporation is a promising nonthermal ablation method for cardiac arrhythmia treatment. Although initial clinical studies found electroporation pulsed-field ablation (PFA) both safe and efficacious, there are significant knowledge gaps concerning the mechanistic nature and electrophysiological consequences of cardiomyocyte electroporation, contributed by the paucity of suitable human in vitro models. Here, we aimed to establish and characterize a functional in vitro model based on human-induced pluripotent stem cells (hiPSCs)-derived cardiac tissue, and to study the fundamentals of cardiac PFA. METHODS: hiPSC-derived cardiomyocytes were seeded as circular cell sheets and subjected to different PFA protocols. Detailed optical mapping, cellular, and molecular characterizations were performed to study PFA mechanisms and electrophysiological outcomes. RESULTS: PFA generated electrically silenced lesions within the hiPSC-derived cardiac circular cell sheets, resulting in areas of conduction block. Both reversible and irreversible electroporation components were identified. Significant electroporation reversibility was documented within 5 to 15-minutes post-PFA. Irreversibly electroporated regions persisted at 24-hours post-PFA. Per single pulse, high-frequency PFA was less efficacious than standard (monophasic) PFA, whereas increasing pulse-number augmented lesion size and diminished reversible electroporation. PFA augmentation could also be achieved by increasing extracellular Ca2+ levels. Flow-cytometry experiments revealed that regulated cell death played an important role following PFA. Assessing for PFA antiarrhythmic properties, sustainable lines of conduction block could be generated using PFA, which could either terminate or isolate arrhythmic activity in the hiPSC-derived cardiac circular cell sheets. CONCLUSIONS: Cardiac electroporation may be studied using hiPSC-derived cardiac tissue, providing novel insights into PFA temporal and electrophysiological characteristics, facilitating electroporation protocol optimization, screening for potential PFA-sensitizers, and investigating the mechanistic nature of PFA antiarrhythmic properties.


Subject(s)
Catheter Ablation , Induced Pluripotent Stem Cells , Humans , Induced Pluripotent Stem Cells/metabolism , Arrhythmias, Cardiac/genetics , Arrhythmias, Cardiac/surgery , Anti-Arrhythmia Agents/therapeutic use , Myocytes, Cardiac/metabolism , Electroporation , Catheter Ablation/methods
4.
Am J Med ; 137(4): 358-365, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38113953

ABSTRACT

INTRODUCTION: Atrioventricular block may be idiopathic or a secondary manifestation of an underlying systemic disease. Cardiac sarcoidosis is a significant underlying cause of high-grade atrioventricular block, posing diagnostic challenges and significant clinical implications. This study aimed to assess the prevalence and clinical characteristics of cardiac sarcoidosis among younger patients presenting with unexplained high-grade atrioventricular block. METHODS: We evaluated patients aged between 18 and 65 years presenting with unexplained high-grade atrioventricular block, who were systematically referred for cardiac magnetic resonance imaging, positron emission tomography-computed tomography, or both, prior to pacemaker implantation. Subjects with suspected cardiac sarcoidosis based on imaging findings were further referred for tissue biopsy. Cardiac sarcoidosis diagnosis was confirmed based on biopsy results. RESULTS: Overall, 30 patients with high-grade atrioventricular block were included in the analysis. The median age was 56.5 years (interquartile range 53-61.75, years). In 37%, cardiac magnetic resonance imaging, positron emission tomography-computed tomography, or both, were suggestive of cardiac sarcoidosis, and in 33% cardiac sarcoidosis was confirmed by tissue biopsy. Compared with idiopathic high-grade atrioventricular block patients, all cardiac sarcoidosis patients were males (100% vs 60%, P = .029), were more likely to present with heart failure symptoms (50% vs 10%, P = .047), had thicker inter-ventricular septum on echocardiography (12.2 ± 2.7 mm vs 9.45 ± 1.6 mm, P = .002), and were more likely to present with right ventricular dysfunction (33% vs 10%, P = .047). CONCLUSIONS: Cardiac sarcoidosis was confirmed in one-third of patients ≤ 65 years, who presented with unexplained high-grade atrioventricular block. Cardiac sarcoidosis should be highly suspected in such patients, particularly in males who present with heart failure symptoms or exhibit thicker inter-ventricular septum and right ventricular dysfunction on echocardiography.


Subject(s)
Atrioventricular Block , Cardiomyopathies , Heart Diseases , Heart Failure , Myocarditis , Sarcoidosis , Ventricular Dysfunction, Right , Adult , Middle Aged , Male , Humans , Adolescent , Young Adult , Aged , Female , Atrioventricular Block/epidemiology , Atrioventricular Block/etiology , Cardiomyopathies/diagnosis , Cardiomyopathies/epidemiology , Cardiomyopathies/complications , Prevalence , Ventricular Dysfunction, Right/complications , Positron-Emission Tomography , Myocarditis/diagnosis , Sarcoidosis/complications , Sarcoidosis/diagnosis , Sarcoidosis/epidemiology , Heart Diseases/complications , Heart Failure/complications
6.
J Clin Med ; 12(20)2023 Oct 23.
Article in English | MEDLINE | ID: mdl-37892833

ABSTRACT

Aim To compare the 1-year survival rate of patients with atrial fibrillation (AF) following left atrial appendage occluder (LAAO) implantation vs. treatment with novel oral anticoagulants (NOACs). METHODS: We have conducted an indirect, retrospective comparison between LAAO and NOAC registries. The LAAO registry is a national prospective cohort of 419 AF patients who underwent percutaneous LAAO between January 2008 and October 2015. The NOACs registry is a multicenter prospective cohort of 3138 AF patients treated with NOACs between November 2015 and August 2018. Baseline patient characteristics were retrospectively collected from coded diagnoses of hospitalization and outpatient clinic notes. Follow-up data was sorted from coded diagnoses and the national civil registry. Subjects were matched according to propensity score. Baseline characteristics were compared using Chi-Square and student's t-test. Survival analysis was performed using Kaplan-Meier survival curves, log-rank test, and multivariable Cox regression, adjusting for possible confounding variables. RESULTS: This study included 114 subjects who underwent LAAO implantation and 342 subjects treated with NOACs. The mean age of participants was 77.9 ± 7.44 and 77.1 ± 11.2 years in the LAAO and NOAC groups, respectively (p = 0.4). The LAAO group had 70 (61%) men compared to 202 (59%) men in the NOAC group (p = 0.74). No significant differences were found in baseline comorbidities, renal function, or CHA2DS2-VASc score. One-year mortality was observed in 5 (4%) patients and 32 (9%) patients of the LAAO and NOAC groups, respectively. After adjusting for confounders, LAAO was significantly associated with a lower risk for 1-year mortality (HR 0.38, 95%CI 0.14-0.99). In patients with impaired renal function, this difference was even more prominent (HR 0.21 for creatinine clearance (CrCl) < 60 mL/min). CONCLUSIONS: In a pooled analysis of two registries, we found a significantly lower risk for 1-year mortality in patients with AF who were implanted with LAAO than those treated with NOACs. This finding was more prominent in patients with impaired renal function. Future prospective direct studies should further investigate the efficacy and adverse effects of both treatment strategies.

7.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37695316

ABSTRACT

AIMS: Several studies have evaluated the use of electrically- or imaging-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT) recipients. We aimed to assess evidence for a guided strategy that targets LV lead position to the site of latest LV activation. METHODS AND RESULTS: A systematic review and meta-analysis was performed for randomized controlled trials (RCTs) until March 2023 that evaluated electrically- or imaging-guided LV lead positioning on clinical and echocardiographic outcomes. The primary endpoint was a composite of all-cause mortality and heart failure hospitalization, and secondary endpoints were quality of life, 6-min walk test (6MWT), QRS duration, LV end-systolic volume, and LV ejection fraction. We included eight RCTs that comprised 1323 patients. Six RCTs compared guided strategy (n = 638) to routine (n = 468), and two RCTs compared different guiding strategies head-to-head: electrically- (n = 111) vs. imaging-guided (n = 106). Compared to routine, a guided strategy did not significantly reduce the risk of the primary endpoint after 12-24 (RR 0.83, 95% CI 0.52-1.33) months. A guided strategy was associated with slight improvement in 6MWT distance after 6 months of follow-up of absolute 18 (95% CI 6-30) m between groups, but not in remaining secondary endpoints. None of the secondary endpoints differed between the guided strategies. CONCLUSION: In this study, a CRT implantation strategy that targets the latest LV activation did not improve survival or reduce heart failure hospitalizations.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/adverse effects , Echocardiography , Heart Failure/diagnosis , Heart Failure/therapy , Heart Ventricles/diagnostic imaging , Hospitalization
8.
J Clin Med ; 12(18)2023 Sep 08.
Article in English | MEDLINE | ID: mdl-37762791

ABSTRACT

In a letter to the editor titled "How to improve clinical outcomes in patients with tachycardia-induced cardiomyopathy", Dr. Naoya Kataoka and Dr. Teruhiko Imamura [...].

9.
J Clin Med ; 12(13)2023 Jun 29.
Article in English | MEDLINE | ID: mdl-37445433

ABSTRACT

Cardiac implantable electronic device (CIED) infection can present with pocket or systemic manifestations, both necessitating complete device removal and pathogen-directed antimicrobial therapy. Here, we aim to characterize those presenting with both pocket and systemic infection. A retrospective analysis of CIED extraction procedures included 300 patients divided into isolated pocket (n = 104, 34.7%), complicated pocket (n = 54, 18%), and systemic infection (n = 142, 47.3%) groups. The systemic and complicated pocket groups frequently presented with leukocytosis and fever > 37.8, as opposed to the isolated pocket group. Staphylococcus aureus was the most common pathogen in the systemic and complicated pocket groups (43.7% and 31.5%, respectively), while Coagulase-negative staphylococci (CONS) predominated (31.7%) in the isolated pocket group (10.6%, p < 0.001). No differences were observed in procedural success or complications rates. Kaplan-Meier survival analysis found that at three years of follow-up, the rate of all-cause mortality was significantly higher among patients with systemic infection compared to both pocket groups (p < 0.001), with the curves diverging at thirty days. In this study, we characterize a new entity of complicated pocket infection. Despite the systemic pattern of infection, their prognosis is similar to isolated pocket infection. We suggest that this special category be presented separately in future publications of CIED infections.

10.
J Clin Med ; 12(11)2023 May 25.
Article in English | MEDLINE | ID: mdl-37297854

ABSTRACT

Even after a successful ventricular tachycardia ablation (VTA), some patients have recurrent ventricular tachycardia (VT) during their follow-up. We assessed the long-term predictors of recurrent VT after having a successful VTA. The patients who underwent a successful VTA (defined as the non-inducibility of any VT at the procedure's end) in 2014-2021 at our center in Israel were retrospectively analyzed. A total of 111 successful VTAs were evaluated. Out of them, 31 (27.9%) had a recurrent event of VT after the procedure during a median follow-up time of 264 days. The mean left ventricular ejection fraction (LVEF) was significantly lower among patients with recurrent VT events (28.9 ± 12.67 vs. 23.53 ± 12.224, p = 0.048). A high number of induced VTs (>two) during the procedure was found to be a significant predictor of VT recurrence (24.69% vs. 56.67%, 20 vs. 17, p = 0.002). In a multivariate analysis, a lower LVEF (HR, 0.964; p = 0.037) and a high number of induced VTs (HR, 2.15; p = 0.039) were independent predictors of arrhythmia recurrence. The inducibility of more than two VTs during a VTA procedure remains a predictor of VT recurrence even after a successful VT ablation. This group of patients remains at high risk for VT and should be followed up with and treated more vigorously.

11.
Front Cardiovasc Med ; 10: 1153275, 2023.
Article in English | MEDLINE | ID: mdl-37304958

ABSTRACT

Background: Postoperative atrial fibrillation (POAF) is the most common complication of cardiac surgery, requiring interventions and prolonging hospital stay. POAF is associated with increased mortality and a higher rate of systemic thrombo-embolism. The rates of recurrent AF, optimal follow-up and management remain unclear. We aimed to evaluate the incidence of recurrent atrial fibrillation (AF) events, during long term follow-up in patients with POAF following cardiac surgery. Methods: Patients with POAF and a CHA2DS2-VASc score of ≥2 were randomized in a 2:1 ratio to either implantation of a loop recorder (ILR) or ECG monitoring using periodic Holters. Participants were followed prospectively for 2 years. The primary end point was the occurrence of AF longer than 5 min. Results: The final cohort comprised of 22 patients, of whom 14 received an ILR. Over a median follow up of 25.7 (IQR of 24.7-44.4) months, 8 patients developed AF, representing a cumulative annualized risk of AF recurrence of 35.7%. There was no difference between ILR (6 participants, 40%) and ECG/Holter (2 participants, 25% p = 0.917). All 8 patients with AF recurrence were treated with oral anticoagulation. There were no cases of mortality, stroke or major bleeding. Two patients underwent ILR explantation due to pain at the implantation site. Conclusions: The rate of recurrent AF in patients with POAF after cardiac surgery and a CHA2DS2-VASc score of ≥2 is approximately 1 in 3 when followed systematically. Further research is need to assess the role of ILRs in this population.

13.
Heliyon ; 9(4): e14790, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37089380

ABSTRACT

Aim: To explore the feasibility and accuracy of virtual reality (VR) derived from cardiac computed angiography (CCTA) data to predict left atrial appendage occlusion (LAAO) device size. Method: Retrospective data of patients who underwent LAAO according to clinical indication were reviewed; all patients underwent a pre-procedural CCTA. Measurements of the left atrial appendage (LAA) orifice diameters by CCTA, VR, and transesophageal echocardiography (TEE) (acquired during the procedure) were compared to the implanted device size. The LAA perimeter was calculated using the Ramanujan approximation. Statistical analyses included Lin's Concordance Correlation Coefficient (ρ c ), the mean difference, and the mean square error (MSE). Results: The sample was composed of 20 patients (mean age 75.7 ± 7.5 years, 60% males) who underwent successful LAAO insertion (ACP™ N = 8, Watchman™ N = 12). The CCTA, VR, and TEE maximal diameter ρ c was 0.52, 0.78 and 0.60, respectively with mean differences of +0.92 ± 4.0 mm, -1.12 ± 2.3 mm, and -3.45 ± 2.69 mm, respectively. The CCTA, VR, and TEE perimeter calculations ρ c were 0.49, 0.54, and 0.39 respectively with mean differences of +4.69 ± 11.5 mm, -9.88 ± 8.0 mm, and -16.79 ± 7.8 respectively. Discussion: A VR visualization of the LAA ostium in different perspectives allows for a better understanding of its funnel-shaped structure. VR measurement of the maximal ostium diameter had the strongest correlation with the diameter of the inserted device. VR may thus provide new imaging possibilities for the evaluation of complex pre-procedural structures such as the LAA.

14.
J Cardiol ; 82(5): 408-413, 2023 11.
Article in English | MEDLINE | ID: mdl-37116647

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) in young adults is an uncommon and not well studied entity. METHODS: Consecutive patients aged 18-45 years admitted to internal or cardiology services in a large tertiary medical center (January 1, 2009 through December 31, 2019) were included. Clinical, electrocardiographic, and echocardiographic data were compared between patients with and without AF at baseline. Predictors of new-onset AF in the young were identified using multivariate Cox regression model among patients free of baseline AF. RESULTS: Final cohort included 16,432 patients with median age of 34 (IQR 26-41) years of whom 8914 (56 %) were men. Patients with AF at baseline (N = 366; 2 %) were older, more likely to be men, and had higher proportion of comorbidities and electrocardiographic conduction disorders. Male sex, increased age, obesity, heart failure, congenital heart disease (CHD) and the presence of left or right bundle branch block were all independently associated with baseline AF in a multivariate model (p < 0.001 for all). Sub-analysis of 10,691 (98 %) patients free of baseline AF identified 85 cases of new-onset AF during a median follow up of 3.5 (IQR 1.5-6.5) years. Multivariate model identified increased age, heart failure, and CHD as independent predictors of new-onset AF. Finally, the CHARGE-AF risk score outperformed the CHA2DS2-VASc score in AF prediction [AUC of ROC 0.75 (0.7-0.8) vs. 0.56 (0.48-0.65)]. CONCLUSIONS: AF among hospitalized young adults is not rare. Screening for new-onset AF in young post hospitalization patients may be guided by specific clinical predictors and the CHARGE-AF risk score.


Subject(s)
Atrial Fibrillation , Heart Failure , Humans , Male , Adult , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/etiology , Risk Assessment , Risk Factors , Heart Failure/complications , Comorbidity
15.
Cardiovasc Diabetol ; 22(1): 77, 2023 03 31.
Article in English | MEDLINE | ID: mdl-37004023

ABSTRACT

BACKGROUND: Diabetes mellitus (DM) type 2 is an independent risk factor for atrial fibrillation (AF). Surgical ablation or "maze procedure" is an option for patients with AF undergoing concomitant or isolated cardiac surgery. The aim of this study was to evaluate the impact of DM type 2 on early and long-term outcomes of patients following surgical AF ablation. METHODS: We performed an observational cohort study in Israel's largest tertiary care center. All data of patients who underwent surgical AF ablation, between 2006 and 2021 were extracted from our departmental database. Patients were divided into Group I (non-diabetic patients) and Group II (DM type 2 patients). We compared the two groups with respect to freedom from recurrent atrial arrhythmia, and mortality rate. RESULTS: The study population included 606 patients. Group I (non-DM patients), consisting of 484 patients, and Group II (DM type 2 patients), comprised 122 patients. Patients with DM were older, had more hypertension and incidence of cerebrovascular accident (CVA)/transient ischemic attack (TIA), higher EuroSCORE (p < .05 for all), and a longer bypass time-130 ± 40 vs. 122 ± 36 min (p = 0.028). The mean follow-up duration was 39.0 ± 22.7 months. Freedom from atrial fibrillation was similar between the non-DM and DM type 2 groups after a 1-year follow-up, 414 (88.2%) vs. 101 (87.1%) (p = 0.511), after a 3-year follow-up, 360 (86.3%) vs. 84 (79.9%) (p = 0.290) and after a 5-year follow-up, 226 (74.1%) vs. 55 (71.5%) (p = 0.622) respectively. Furthermore, 1- and 3-year mortality was similar between non-DM and DM type 2 groups, 2.5% vs. 4.9%, (p = 0.226) and 5.6% vs. 10.5% (p = 0.076) respectively. 5-year mortality was higher in Group II (DM type 2 patients) compared with Group I (non-DM patients), 11.1% vs. 23.4% (p = 0.009). CONCLUSION: Surgical ablation had a high success rate, with freedom from recurrent atrial arrhythmia at 1- 3- and 5- years follow-up in both the DM type 2 and non-DM groups. Furthermore,1- and 3-year mortality after surgical ablation was also similar in both groups. However, 5-year mortality was higher in the DM type 2 group.


Subject(s)
Atrial Fibrillation , Cardiac Surgical Procedures , Diabetes Mellitus, Type 2 , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Treatment Outcome , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/diagnosis , Risk Factors , Cardiac Surgical Procedures/adverse effects
17.
J Clin Med ; 12(4)2023 Feb 10.
Article in English | MEDLINE | ID: mdl-36835947

ABSTRACT

BACKGROUND: data on the natural course and prognosis of tachycardia-induced cardiomyopathy (TICMP) and comparison with idiopathic dilated cardiomyopathies (IDCM) are scarce. OBJECTIVE: To compare the clinical presentation, comorbidities, and long-term outcomes of TICMP patients with IDCM patients. METHODS: a retrospective cohort study of patients hospitalized with new-onset TICMP or IDCM. The primary endpoint was a composite of death, myocardial infarction, thromboembolic events, assist device, heart transplantation, and ventricular tachycardia or fibrillation (VT/VF). The secondary endpoint was recurrent hospitalization due to heart failure (HF) exacerbation. RESULTS: the cohort was comprised of 64 TICMP and 66 IDCM patients. The primary composite endpoint and all-cause mortality were similar between the groups during a median follow-up of ~6 years (36% versus 29%, p = 0.33 and 22% versus 15%, p = 0.15, respectively). Survival analysis showed no significant difference between TICMP and IDCM groups for the composite endpoint (p = 0.75), all-cause mortality (p = 0.65), and hospitalizations due to heart failure exacerbation. Nonetheless, the incidence of recurrent hospitalization was significantly higher in TICMP patients (incidence rate ratio 1.59; p = 0.009). CONCLUSIONS: patients with TICMP have similar long-term outcomes as those with IDCM. However, it portends a higher rate of HF readmissions, mostly due to arrhythmia recurrences.

18.
J Am Coll Cardiol ; 81(2): 119-133, 2023 01 17.
Article in English | MEDLINE | ID: mdl-36631206

ABSTRACT

BACKGROUND: Present guidelines endorse complete removal of cardiovascular implantable electronic devices (pacemakers/defibrillators), including extraction of all intracardiac electrodes, not only for systemic infections, but also for localized pocket infections. OBJECTIVES: The authors evaluated the efficacy of delivering continuous, in situ-targeted, ultrahigh concentration of antibiotics (CITA) into the infected subcutaneous device pocket, obviating the need for device/lead extraction. METHODS: The CITA group consisted of 80 patients with pocket infection who were treated with CITA during 2007-2021. Of them, 9 patients declined lead extraction because of prohibitive operative risk, and 6 patients had questionable indications for extraction. The remaining 65 patients with pocket infection, who were eligible for extraction, but opted for CITA treatment, were compared with 81 patients with pocket infection and similar characteristics who underwent device/lead extraction as primary therapy. RESULTS: A total of 80 patients with pocket infection were treated with CITA during 2007-2021. CITA was curative in 85% (n = 68 of 80) of patients, who remained free of infection (median follow-up 3 years [IQR: 1.0-6.8 years]). In the case-control study of CITA vs device/lead extraction, cure rates were higher after device/lead extraction than after CITA (96.2% [n = 78 of 81] vs 84.6% [n = 55 of 65]; P = 0.027). However, rates of serious complications were also higher after extraction (n = 12 [14.8%] vs n = 1 [1.5%]; P = 0.005). All-cause 1-month and 1-year mortality were similar for CITA and device/lead extraction (0.0% vs 3.7%; P = 0.25 and 12.3% vs 13.6%; P = 1.00, respectively). Extraction was avoided in 90.8% (n = 59 of 65) of extraction-eligible patients treated with CITA. CONCLUSIONS: CITA is a safe and effective alternative for patients with pocket infection who are unsuitable or unwilling to undergo extraction. (Salvage of Infected Cardiovascular Implantable Electronic Devices [CIED] by Localized High-Dose Antibiotics; NCT01770067).


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Anti-Bacterial Agents , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Case-Control Studies , Device Removal , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/etiology , Retrospective Studies
19.
Europace ; 25(3): 956-960, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36636968

ABSTRACT

AIMS: Intraoperative defibrillation testing (DT) during implant or replacement of implantable cardioverter-defibrillators (ICDs) has been a matter of debate for many years. This debate was put to rest by the Simple and Nordic ICD trials, and the practice of testing during new implantations has essentially been almost abandoned. Old registries demonstrated an increased incidence of significant findings in DT during replacements. The aim of the present study was to evaluate frequency of significant findings and safety of DT in subjects undergoing device replacement. METHODS AND RESULTS: A prospective observational multi-centre study included consecutive patients undergoing ICD generator replacement. The primary outcome was a failure to terminate induced ventricular fibrillation (VF) with a single shock 10 J below the maximal capacity of the device. Secondary outcomes included complications of DT. Patients were followed-up at 1- and 6-months post-procedure. A total of 92 patients were eligible, and consented to the study, of which 84 underwent DT during battery replacement. The median age was 68 years and 79.8% were males. Induction of VF was successful in 84 patients as was a successful conversion on the first attempt in all. There were no procedure-related complications. During follow up one patient had two appropriate ICD shock events. In four patients, ICD programming was changed. None suffered inappropriate shock. There was no evidence of lead malfunction. Two deaths occurred, none of which was related to arrhythmia. CONCLUSION: The present study found DT was not associated with complications in patients undergoing ICD generator replacement but produced no clinically important information.


Subject(s)
Defibrillators, Implantable , Male , Humans , Aged , Female , Defibrillators, Implantable/adverse effects , Arrhythmias, Cardiac/etiology , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/etiology , Ventricular Fibrillation/therapy
20.
Front Cardiovasc Med ; 9: 998079, 2022.
Article in English | MEDLINE | ID: mdl-36329994

ABSTRACT

Objectives: Ventricular tachycardia ablation (VTA) with hemodynamic compromise presents a challenge. Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support allows the safe completion of the procedure. There are limited data regarding the safety of weaning off VA-ECMO at the end of the procedure. We report our experience with early VA-ECMO de-cannulation after VTA. Materials and methods: All patients undergoing VA-ECMO-assisted VTA, between January 2013 and December 2020 at a large tertiary center were included. Clinical characteristics, history of arrhythmia, procedural details, and outcomes were collected. Patients weaned from VA-ECMO immediately at the end of the procedure were compared to those that were de-cannulated at a later time. Results: A total of 46 patients (93.5% male, age 62 ± 10 years) were ablated with VA-ECMO support. Most had ischemic cardiomyopathy (65%) and (70%) presented with VT storm. The clinical VT was induced in the majority of patients (76%). A total of 99 VTs were induced of which 76 (77%) were targeted and successfully ablated. Non-inducibility was achieved in 74% of cases and most patients (83%) were de-cannulated at the end of the procedure on the procedure table. Survival at 1 year was higher among early de-cannulated patients (86 vs. 38% [log-rank p-value < 0.001]). At 1-year follow-up, 91.3% of surviving patients were free of appropriate ICD shocks. Conclusion: De-cannulation from VA-ECMO may be done immediately at the conclusion of VTA in most cases. Failure to timely wean off VA-ECMO is a strong predictor of mortality.

SELECTION OF CITATIONS
SEARCH DETAIL
...