Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
J Phys Condens Matter ; 35(30)2023 Apr 28.
Article in English | MEDLINE | ID: mdl-37075774

ABSTRACT

We use terahertz time-domain spectroscopy to study gallium arsenide two-dimensional electron gas samples in external magnetic field. We measure cyclotron decay as a function of temperature from 0.4 to10Kand a quantum confinement dependence of the cyclotron decay time belowT0=1.2K. In the wider quantum well, we observe a dramatic enhancement in the decay time due to the reduction in dephasing and the concomitant enhancement of superradiant decay in these systems. We show that the dephasing time in 2DEG's depends on both the scatteringrateand also on the distribution of scattering angles.

2.
Int J Cardiol ; 321: 24-29, 2020 Dec 15.
Article in English | MEDLINE | ID: mdl-32800911

ABSTRACT

OBJECTIVE: We aimed to assess the use of enhanced stent visualisation (ESV) on outcomes, after PCI with overlapping stents, specifically using CLEARstent technology. BACKGROUND: Stent underexpansion and overlap are both significant risk factors for restenosis and stent thrombosis. Enhanced stent visualisation (e.g. CLEARstent) systems could provide important data to reduce under-expansion and stent overlap. METHODS: This was a cohort study based on this institution's percutaneous coronary intervention (PCI) registry. A total of 2614 patients who had PCI for stable angina or acute coronary syndromes (ACS, excluding cardiogenic shock) with overlapping 2nd generation drug eluting stents (DES) in the same vessel between May 2015 and January 2018 were included in the analysis. Patients were divided into ESV (n = 1354) and no ESV guided intervention (n = 1260). The primary end-point was major adverse cardiovascular events (MACE: target vessel revascularisation, target vessel myocardial infarction and all-cause mortality) recorded at a median follow up of 2.4 years. RESULTS: Groups were comparable for patient characteristics (age, diabetes mellitus, ACS presentation). A significant difference in MACE was observed between patients who underwent ESV-guided PCI (9.5%) compared with patients who underwent Standard PCI (14.4%, p = .018). This difference was mainly driven by reduced rates of target vessel revascularisation and recurrent myocardial infarction. Overall this difference persisted after multivariate Cox analysis (HR 0.86, 95% CI: 0.73-0.98) and propensity matching (HR = 0.88, 95% CI: 0.69-0.99). CONCLUSION: We suggest that routine clinical use of ESV technology during PCI can be useful, and is associated with better medium-term angiographic and clinical outcomes. Further study is required to build on this promising signal.


Subject(s)
Percutaneous Coronary Intervention , Angiography , Cohort Studies , Coronary Angiography , Humans , Percutaneous Coronary Intervention/adverse effects , Risk Factors , Stents , Treatment Outcome
4.
Psychol Health Med ; 5(2): 173-178, 2000 May.
Article in English | MEDLINE | ID: mdl-29156955

ABSTRACT

Current work on insight focuses on its assessment, a trend that is reflected in the inflation of newly-developed scales. Most scales assess compliance with treatment, recognition and acceptance of mental illness and relabeling of abnormal mental experience as pathological. A handful of studies indicate that compliance is weakly to moderately correlated with awareness of illness and relabelling of symptoms in acute samples. As the parameters of compliance differ between acute and chronic populations, this study investigated the relationship between the three components using the Schedule to Assess the Components of Insight in 78 outpatients with chronic schizophrenia. A weak positive correlation was found between acceptance of illness and relabelling. However, compliance was not reliably related to either the awareness or relabelling component. As the incidence of non-compliance in the present sample did not differ from comparable populations, it appears that non-compliance does not account for these findings. Non-compliance may be viewed as an evaluation of the costs and benefits of treatment on daily living rather than an insight deficit. The lack of a reliable relationship between compliance and insight suggests that the two phenomena should be viewed as distinct constructs and assessed separately in chronic schizophrenia.

6.
Ir J Med Sci ; 160 Suppl 9: 10-6, 1991 Jan.
Article in English | MEDLINE | ID: mdl-1938316

ABSTRACT

Ireland has one of the highest death rates in the world from coronary heart disease (CHD) and has not shared in the rapid decline in mortality which has occurred in other countries. The Kilkenny Health Project was established as a community-based research and demonstration programme for cardiovascular disease prevention in County Kilkenny and as a pilot project for future national initiatives. The first phase of the health promotion programme in Kilkenny is being carried out between 1985 and 1990. Changes in behaviour and in factors associated with CHD will be estimated by the difference in changes over time between Kilkenny and the reference area, as measured by independent random sample surveys of men and women aged 35 to 64 years. CHD and stroke events, fatal and non-fatal, will be registered in both areas from 1987-1992. The Project has studied attitudes to CHD and its prevention. Health behaviours have been studied in adults and in post-primary school pupils. Risk factors for CHD have been measured in adults in accordance with the methods of the international MONICA Project. It has been demonstrated that health and education professionals can incorporate preventive activities and health education into everyday practice.


Subject(s)
Cardiovascular Diseases/prevention & control , Health Promotion/methods , Adult , Female , Humans , Ireland , Male , Middle Aged , Program Evaluation , Risk Factors
7.
Cornell Vet ; 77(1): 21-32, 1987 Jan.
Article in English | MEDLINE | ID: mdl-3542382

ABSTRACT

The development and adaptation of a fluorescent immunoassay for determining changes in canine haptoglobin levels is described. Levels of canine haptoglobin determined by the fluorescent immunoassay from a group of healthy dog sera (68.0 mg/dl) compared favorably to the haptoglobin levels determined by a spectrophotometric method (74.5 mg/dl). The fluorescent immunoassay offered several advantages over currently used methods for determining levels of canine haptoglobin in serum.


Subject(s)
Dogs/blood , Haptoglobins/analysis , Animals , Fluorescent Antibody Technique , Immunoassay
8.
J Clin Microbiol ; 21(6): 930-5, 1985 Jun.
Article in English | MEDLINE | ID: mdl-2989326

ABSTRACT

Immunoglobulin M (IgM) antibodies were detected by a commercially available enzyme-Linked Immunosorbent Assay (ELISA) in 36 of 49 (73%) pregnant women with primary cytomegalovirus (CMV) infection. A positive ELISA-IgM result occurred in 10 of 13 patients (77%) assessed within 8 weeks of seroconversion. The sensitivity of the radioimmunoassay (RIA) to identify primary infection in pregnant women was comparable, 78% in general and 86% for women tested within 16 weeks of seroconversion. Of the 36 women with primary infection who had detectable IgM antibodies by ELISA, 25 (69%) were delivered of congenitally infected infants, whereas of the 13 with undetectable IgM antibodies, 7 (54%) transmitted the infection in utero. IgM antibodies were detected by ELISA in only 5 of 43 (11%) women who experienced a recurrence of CMV which either did or did not result in congenital infection. RIA was less likely to measure CMV-specific IgM in recurrent infection, inasmuch as 1 of 19 (5.2%) women with proven recurrent infection had detectable IgM antibody, giving RIA a better specificity for primary infection. Specific IgM antibodies were detected by ELISA in 42 of 61 (69%) babies congenitally infected with CMV and in 4 of 70 (5.7%) uninfected control newborn infants. The RIA was superior for diagnosis of congenital CMV infection, with a sensitivity of 89% and a specificity of 100%. The lower sensitivity of the ELISA-IgM occurred in the category of congenitally infected infants born to mothers with recurrent infection (43%), a group that is at the lowest risk of disease or to develop sequelae. This commercially available ELISA-IgM could be used in combination with a CMV-specific IgG test for monitoring women during pregnancy for primary infection.


Subject(s)
Antibodies, Viral/analysis , Cytomegalovirus Infections/diagnosis , Cytomegalovirus/immunology , Infant, Newborn, Diseases/diagnosis , Pregnancy Complications, Infectious/diagnosis , Enzyme-Linked Immunosorbent Assay , Female , Fetal Blood/immunology , Humans , Immunoglobulin M/analysis , Infant, Newborn , Pregnancy , Radioimmunoassay , Reagent Kits, Diagnostic/standards
9.
J Clin Microbiol ; 20(6): 1140-4, 1984 Dec.
Article in English | MEDLINE | ID: mdl-6394616

ABSTRACT

A 1-h enzyme-linked immunosorbent assay (Rubestat) was developed for rubella virus immunoglobulin G detection. The assay used phenolphthalein monophosphate as the substrate, which, when developed, can easily be read visually. Rubestat compared very favorably to hemagglutination inhibition and commercial enzyme-linked immunosorbent assays in its ability to determine immune status. Rubestat demonstrated greater than 97% specificity, sensitivity, and accuracy as compared with other methodologies at 10 different laboratories. The Rubestat index values were precise, with coefficients of variation for intra- and interassay variation of less than 10%. Mean index values had a linear correlation with hemagglutination inhibition titers (r2 greater than 0.97). A population distribution of index values illustrated two distinct bell-shaped curves representing the positive and negative populations. Studies of acute and convalescent serum pairs showed Rubestat to be as accurate as hemagglutination inhibition in determining seroconversion.


Subject(s)
Antibodies, Viral/analysis , Enzyme-Linked Immunosorbent Assay , Immunoenzyme Techniques , Rubella virus/immunology , Evaluation Studies as Topic , Hemagglutination Inhibition Tests , Humans , Immunoglobulin G/analysis , Immunoglobulin M/analysis
10.
J Clin Microbiol ; 17(5): 814-8, 1983 May.
Article in English | MEDLINE | ID: mdl-6863500

ABSTRACT

An enzyme-linked immunosorbent assay (ELISA) was developed for the detection of measles immunoglobulin G antibody (MEASELISA). This assay was found to be comparable to the measles hemagglutination inhibition (HAI) test. Approximately 500 sera from three centers were tested by MEASELISA and the HAI test. MEASELISA demonstrated values of greater than 99% for sensitivity, specificity, and accuracy. Values were very precise, with a mean coefficient of variation of 5.4%. MEASELISA values were shown by linear regression analysis to increase as HAI titers increased. A coefficient of determination of 1.00 was obtained from test center three. MEASELISA values were found to be linearly related (r2 greater than 0.97) to MEASELISA titers, thus enabling quantitation of measles antibody from a single value. Also, data are presented that show MEASELISA to be equivalent to complement fixation for evaluating paired sera for the presence of a significant increase in antibody levels to measles virus.


Subject(s)
Antibodies, Viral/analysis , Immunoglobulin G/analysis , Measles/immunology , Enzyme-Linked Immunosorbent Assay , Hemagglutination Inhibition Tests , Humans , Reagent Kits, Diagnostic
11.
Arch Virol ; 78(3-4): 203-12, 1983.
Article in English | MEDLINE | ID: mdl-6318694

ABSTRACT

A new commercially developed cytomegalovirus (CMV)-IgM ELISA was found to be sensitive and specific when compared with sucrose gradient fractionation of Ig classes in CMV antibody-positive and negative sera. The presence of CMV IgM in patients' sera correlated with positive virus isolation from circulating mononuclear blood cells and urine. Serial examinations of patients with primary or recent CMV infection revealed a typical sequence of IgM and IgG development. The frequency of CMV isolation declined as the concentration of IgM decreased and the IgG levels increased. Since the isolation of CMV from clinical specimens is a cumbersome procedure, we suggest that the IgM ELISA could provide rapid and valuable information on the presence of an active or reactivated CMV infection.


Subject(s)
Cytomegalovirus Infections/diagnosis , Cytomegalovirus/immunology , Enzyme-Linked Immunosorbent Assay , Homosexuality , Immunoenzyme Techniques , Immunoglobulin M/analysis , Immunologic Deficiency Syndromes/complications , Adult , Aged , Antibodies, Viral/analysis , Complement Fixation Tests , Cytomegalovirus/isolation & purification , Cytomegalovirus Infections/complications , Cytomegalovirus Infections/immunology , Female , Humans , Immunoglobulin G/analysis , Lymphocytes/microbiology , Male , Middle Aged , Urine/microbiology
12.
Arch Virol ; 66(4): 321-7, 1980.
Article in English | MEDLINE | ID: mdl-7447708

ABSTRACT

The level of humoral and cell mediated immunity in persons with low or undetectable hemagglutination-inhibition (HAI) rubella titers was investigated by ELISA, IgG presence in sucrose gradient separated serum fractions and lymphocyte transformation. The study population consisted of persons with stated history of natural rubella infection and rubella vaccinees. Persons with natural rubella infection and HAI titers of 1:8 or +/- 1:8 (i.e., incomplete HAI at serum dilution of 1:8) were all ELISA positive and the stimulation index (SI) of specific lymphocyte transformation was higher than 2.5. Among the 20 persons with HAI titers of < 1:8, 8 were found to be ELISA positive and their SI was also > 2 and IgG was detected in their serum. Rubella vaccinees with HAI titers of 1:8 or +/- 1:8 were likewise ELISA positive. Their SI was lower: none higher than 3, but none lower than 1.5. Among 23 HAI negative vaccinees, 14 were found ELISA positive. This serum fraction contained IgG and the SI was > 1.5. It appears that ELISA test is able to detect antibodies where the HAI test fails. The positive outcome of ELISA test in this case was confirmed by the presence of IgG in serum fractions and by the lymphocyte response to rubella specific stimulation.


Subject(s)
Antibodies, Viral/analysis , Lymphocyte Activation , Rubella virus/immunology , Enzyme-Linked Immunosorbent Assay , Hemagglutination Inhibition Tests , Humans , Rubella/immunology , Rubella Vaccine/immunology
13.
J Clin Microbiol ; 10(4): 595-7, 1979 Oct.
Article in English | MEDLINE | ID: mdl-231052

ABSTRACT

An enzyme-linked immunosorbent assay was developed for the detection of antibodies to murine hepatitis virus. A high prevalence of antibody to murine hepatitis virus was found by the enzyme-linked immunosorbent assay in colonies with a low prevalence of complement-fixing antibodies. Murine hepatitis virus strain A59 was found to be broadly reactive as an enzyme-linked immunosorbent assay antigen.


Subject(s)
Antibodies, Viral/analysis , Enzyme-Linked Immunosorbent Assay , Immunoenzyme Techniques , Murine hepatitis virus/immunology , Age Factors , Animals , Complement Fixation Tests , Mice , Mice, Inbred BALB C/immunology
14.
J Histochem Cytochem ; 27(8): 1148-62, 1979 Aug.
Article in English | MEDLINE | ID: mdl-383822

ABSTRACT

During the past 10 to 15 years immunoassays have gained acceptance as the methods of choice in the diagnosis of a number of disease states. At present the immunodiagnostic techniques employed range from radioimmunoassay for haptens through immunofluorescence for autoimmune diseases to complement fixation for viral infections. All of these assays have their own individual limitations such as: safety, short shelf life and sensitivity. The development of enzyme immunoassays, in particular enzyme linked immunosorbent assay (ELISA), has led to a substantial literature which offers the view that enzyme immunoassays provide a safe, sensitive and specific alternative to standard methods for the detection of antibodies or antigens. The application of heterogeneous enzyme linked immunosorbent assays for the quantitation of haptens, macromolecular antigens and antibodies is reviewed.


Subject(s)
Enzyme-Linked Immunosorbent Assay , Immunoenzyme Techniques , Antibodies/analysis , Antigen-Antibody Reactions , Antigens/analysis , Haptens/analysis , Humans
15.
J Clin Microbiol ; 9(3): 444-7, 1979 Mar.
Article in English | MEDLINE | ID: mdl-222802

ABSTRACT

The enzyme-linked immunosorbent assay technique for detection of Sendai virus antibody in mice was approximately 100- and 300-fold more sensitive than the complement fixation and hemagglutination inhibition tests, respectively. The assay also permitted direct quantitative measurement of the amount of antibody on a single serum dilution rather than by the more traditional serial titration.


Subject(s)
Antibodies, Viral/analysis , Complement Fixation Tests , Enzyme-Linked Immunosorbent Assay , Hemagglutination Inhibition Tests , Immunoenzyme Techniques , Parainfluenza Virus 1, Human/immunology , Paramyxoviridae Infections/immunology , Animals , Antibodies, Viral/biosynthesis , Mice
SELECTION OF CITATIONS
SEARCH DETAIL
...