Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
2.
Am J Gastroenterol ; 112(10): 1538-1544, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28809387

ABSTRACT

OBJECTIVES: Management of eosinophilic esophagitis (EoE) requires repeated endoscopic mucosal sampling to assess disease activity. A less invasive and expensive means of monitoring of EoE is required. The objective of this study was to assess the accuracy, safety, and tolerability of the cytosponge compared to endoscopy and biopsy for histologic assessment of EoE. METHODS: In this prospective two-center cross-sectional study, patients with known EoE underwent cytosponge sampling followed by endoscopy and biopsy. Sample adequacy and eosinophil counts (eos/HPF) were determined for both cytosponge and endoscopic samples. The cytosponge was assessed for diagnostic accuracy, safety, and patient preference as compared to endoscopy. RESULTS: Six patients (7%) failed to swallow the sponge. One hundred and five procedures were successfully performed in 80 patients (66% male, 100% white, 19% stricture). The cytosponge sample was adequate in 102 and the biopsy in 104; 101 procedures had adequate samples by both techniques. Fifty-seven biopsies were graded as active EoE with ≥15 eos/HPF as the gold standard. Eosinophil counts highly correlated between the biopsy and cytosponge (r=0.78, P<0.0001). Using a cutoff of ≤15 eos/HPF for inactive disease, the sensitivity and specificity of the cytosponge was 75% and 86%, respectively. Six patients had active EoE on cytosponge not found on biopsy. For biopsies with inactive EoE, the cytosponge identified 38/44. No complications occurred, and cytosponge endoscopic abrasion scores were low (0.34/4). Patients preferred cytosponge to endoscopy with higher rating scores (7.27 vs. 6.11, P=0.002). CONCLUSIONS: Compared to endoscopy with biopsy, cytosponge provided a minimally invasive, safe, well tolerated, and accurate method to assess EoE histologic activity. (ClinicalTrial.gov number NCT01585103).


Subject(s)
Biopsy/methods , Eosinophilic Esophagitis , Eosinophils/pathology , Esophagoscopy/methods , Mucous Membrane/pathology , Specimen Handling , Surgical Sponges , Adult , Cell Count/methods , Cross-Sectional Studies , Dimensional Measurement Accuracy , Eosinophilic Esophagitis/diagnosis , Eosinophilic Esophagitis/epidemiology , Eosinophilic Esophagitis/pathology , Esophagus/pathology , Female , Humans , Male , Middle Aged , Monitoring, Physiologic/methods , Patient Acuity , Patient Preference , Prospective Studies , Specimen Handling/methods , Specimen Handling/psychology , Statistics as Topic , United States/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...