1.
Nat Commun ; 15(1): 1563, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38378716

ABSTRACT

A general-purpose photonic processor can be built integrating a silicon photonic programmable core in a technology stack comprising an electronic monitoring and controlling layer and a software layer for resource control and programming. This processor can leverage the unique properties of photonics in terms of ultra-high bandwidth, high-speed operation, and low power consumption while operating in a complementary and synergistic way with electronic processors. These features are key in applications such as next-generation 5/6 G wireless systems where reconfigurable filtering, frequency conversion, arbitrary waveform generation, and beamforming are currently provided by microwave photonic subsystems that cannot be scaled down. Here we report the first general-purpose programmable processor with the remarkable capability to implement all the required basic functionalities of a microwave photonic system by suitable programming of its resources. The processor is fabricated in silicon photonics and incorporates the full photonic/electronic and software stack.

2.
Invest Ophthalmol Vis Sci ; 58(9): 3471-3480, 2017 07 01.
Article in English | MEDLINE | ID: mdl-28700779

ABSTRACT

Purpose: To evaluate corneal wound healing after treatment with a new collagen crosslinking protocol using rose bengal dye and green light (RGX). Methods: One cornea of 20 New Zealand rabbits was de-epithelialized (DE) in an 8-mm diameter circle and, in another group (n = 25), the DE corneas were then stained with 0.1% rose bengal for 2 minutes and exposed to green light (532 nm) for 7 minutes (RGX). The contralateral eyes without treatment acted as controls. The animals were clinically followed including fluorescein staining and pachymetry. Healing events were analyzed after euthanasia at 2, 30, and 60 days. Cell death (TUNEL assay), cell proliferation (5-bromo-2'-deoxyuridine incorporation), and cell differentiation to myofibroblasts (α-SMA labeling) were carried out. In addition, loss of keratocytes and subsequent repopulation of the corneal stroma were quantified on hematoxylin-eosin-stained sections. Results: Wound closure was slower after RGX (4.4 days) then after DE (3.3 days). Cell death was restricted to the anterior central stroma, and the cellular decrease did not differ significantly between RGX and DE corneas. Cell proliferation in the epithelium and stroma appeared at 2 days. In both DE and RGX corneas, recovery of the epithelium was complete at day 30, although cell repopulation of the stroma was not complete at 60 days. Conclusions: The healing response in corneas after RGX is very similar to that observed after DE alone, suggesting that, along with its short treatment time and limited effect on keratocytes, RGX displays good potential for clinical cornea stiffening.


Subject(s)
Collagen/pharmacology , Cornea/pathology , Corneal Injuries/drug therapy , Cross-Linking Reagents/pharmacology , Light , Rose Bengal/pharmacology , Wound Healing/drug effects , Animals , Cornea/drug effects , Disease Models, Animal , Female , Fluorescent Dyes/pharmacology , Rabbits
3.
Invest Ophthalmol Vis Sci ; 58(3): 1612-1620, 2017 03 01.
Article in English | MEDLINE | ID: mdl-28297026

ABSTRACT

Purpose: To compare corneal biomechanical properties after in vivo and ex vivo cross-linking (CXL) using rose bengal-green light (RGX) or riboflavin-UVA (UVX). Methods: Corneas of 30 rabbits were treated in vivo by the two CXL modalities monolaterally (Group 1) or bilaterally (Group 2). Rabbits in Group 1 were euthanized 1 month after treatments and in Group 2 two months after treatment. Ex vivo CXL was also performed. Eyes were measured by Scheimpflug air puff corneal deformation imaging (Corvis ST) under constant IOP. Corneal deformation parameters were assessed. Inherent corneal biomechanical properties were estimated using inverse finite element modeling. Results: Peak to peak distance decreased 16% 2 months after RGX, and 4% and 20% 1 and 2 months after UVX, respectively. The equivalent Young's modulus (Eeq) increased relative to the control during the post treatment period for both RGX and UVX. The Eeq increased by factors of 3.4 (RGX) and 1.7 (UVX) 1 month and by factors of 10.7 (RGX) and 7.3 (UVX) 2 months after treatment. However, the Eeq values for ex vivo CXL were much greater than produced in vivo. The ex vivo Eeq was greater than the 1-month in vivo values by factors of 8.1 (RGX) and 9.1 (UVX) and compared with 2 month by factors of 2.5 (RGX) and 2.1 (UVX). Conclusions: These results indicate that corneal stiffness increases after CXL, and further increases as a function of time after both RGX and UVX. Also, while biomechanical properties determined after ex vivo CXL are indicative of corneal stiffening, they may not provide entirely accurate information about the responses to CXL in vivo.


Subject(s)
Collagen/pharmacology , Corneal Diseases/drug therapy , Corneal Stroma/physiopathology , Cross-Linking Reagents/pharmacology , Riboflavin/pharmacology , Rose Bengal/pharmacology , Ultraviolet Rays , Animals , Corneal Diseases/pathology , Corneal Diseases/physiopathology , Corneal Stroma/drug effects , Corneal Stroma/pathology , Disease Models, Animal , Elasticity , Fluorescent Dyes/pharmacology , Photosensitizing Agents/pharmacology , Rabbits
4.
PLoS One ; 11(10): e0165669, 2016.
Article in English | MEDLINE | ID: mdl-27792759

ABSTRACT

OBJECTIVE: To validate a new method for reconstructing corneal biomechanical properties from air puff corneal deformation images using hydrogel polymer model corneas and porcine corneas. METHODS: Air puff deformation imaging was performed on model eyes with artificial corneas made out of three different hydrogel materials with three different thicknesses and on porcine eyes, at constant intraocular pressure of 15 mmHg. The cornea air puff deformation was modeled using finite elements, and hyperelastic material parameters were determined through inverse modeling, minimizing the difference between the simulated and the measured central deformation amplitude and central-peripheral deformation ratio parameters. Uniaxial tensile tests were performed on the model cornea materials as well as on corneal strips, and the results were compared to stress-strain simulations assuming the reconstructed material parameters. RESULTS: The measured and simulated spatial and temporal profiles of the air puff deformation tests were in good agreement (< 7% average discrepancy). The simulated stress-strain curves of the studied hydrogel corneal materials fitted well the experimental stress-strain curves from uniaxial extensiometry, particularly in the 0-0.4 range. Equivalent Young´s moduli of the reconstructed material properties from air-puff were 0.31, 0.58 and 0.48 MPa for the three polymer materials respectively which differed < 1% from those obtained from extensiometry. The simulations of the same material but different thickness resulted in similar reconstructed material properties. The air-puff reconstructed average equivalent Young´s modulus of the porcine corneas was 1.3 MPa, within 18% of that obtained from extensiometry. CONCLUSIONS: Air puff corneal deformation imaging with inverse finite element modeling can retrieve material properties of model hydrogel polymer corneas and real corneas, which are in good correspondence with those obtained from uniaxial extensiometry, suggesting that this is a promising technique to retrieve quantitative corneal biomechanical properties.


Subject(s)
Air , Cornea/physiology , Intraocular Pressure , Models, Biological , Tonometry, Ocular , Animals , Finite Element Analysis , Phantoms, Imaging , Stress, Mechanical , Swine , Tensile Strength
5.
Invest Ophthalmol Vis Sci ; 57(3): 992-1001, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26968733

ABSTRACT

PURPOSE: To compare the biomechanical corneal response of two different corneal cross-linking (CXL) treatments, rose bengal-green light (RGX) and riboflavin-UVA (UVX), using noninvasive imaging. METHODS: A total of 12 enucleated rabbit eyes were treated with RGX and 12 with UVX. Corneal dynamic deformation to an air puff was measured by high speed Scheimpflug imaging (Corvis ST) before and after treatment. The spatial and temporal deformation profiles were evaluated at constant intraocular pressure of 15 mm Hg, and several deformation parameters were estimated. The deformation profiles were modeled numerically using finite element analysis, and the hyperelastic corneal material parameters were obtained by inverse modeling technique. RESULTS: The corneal deformation amplitude decreased significantly after both CXL methods. The material parameters obtained from inverse modeling were consistent with corneal stiffening after both RGX and UVX. Within the treated corneal volume, we found that the elasticity decreased by a factor of 11 after RGX and by a factor of 6.25 after UVX. CONCLUSIONS: The deformation of UVX-treated corneas was smaller than the RGX-treated corneas. However, the reconstructed corneal mechanical parameters reveal that RGX produced in fact larger stiffening of the treated region (100-µm depth) than UVX (137-µm depth). Rose bengal-green light stiffens the cornea effectively, with shorter treatment times and shallower treated areas. Dynamic air puff deformation imaging coupled with mechanical simulations is a useful tool to characterize corneal biomechanical properties, assess different treatments, and possibly help optimize the treatment protocols.


Subject(s)
Collagen/therapeutic use , Cornea/physiopathology , Cross-Linking Reagents/therapeutic use , Keratoconus/drug therapy , Riboflavin/therapeutic use , Rose Bengal/therapeutic use , Ultraviolet Rays , Animals , Cornea/drug effects , Elasticity , Fluorescent Dyes/therapeutic use , Keratoconus/physiopathology , Photosensitizing Agents/therapeutic use , Rabbits
6.
J R Soc Interface ; 11(101): 20140920, 2014 Dec 06.
Article in English | MEDLINE | ID: mdl-25320067

ABSTRACT

Most techniques measuring corneal biomechanics in vivo are biased by side factors. We demonstrate the ability of optical coherence tomographic (OCT) vibrography to determine corneal material parameters, while reducing current prevalent restrictions of other techniques (such as intraocular pressure (IOP) and thickness dependency). Modal analysis was performed in a finite-element (FE) model to study the oscillation response in isolated thin corneal flaps/eye globes and to analyse the dependency of the frequency response function on: corneal elasticity, viscoelasticity, geometry (thickness and curvature), IOP and density. The model was verified experimentally in flaps from three bovine corneas and in two enucleated porcine eyes using sound excitation (100-110 dB) together with a phase-sensitive OCT to measure the frequency response function (range 50-510 Hz). Simulations showed that corneal vibration in flaps is sensitive to both, geometrical and biomechanical parameters, whereas in whole globes it is primarily sensitive to corneal biomechanical parameters only. Calculations based on the natural frequency shift revealed that flaps of the posterior cornea were 0.8 times less stiff than flaps from the anterior cornea and cross-linked corneas were 1.6 times stiffer than virgin corneas. Sensitivity analysis showed that natural vibration frequencies of whole globes were nearly independent from corneal thickness and IOP within the physiological range. OCT vibrography is a promising non-invasive technique to measure corneal elasticity without biases from corneal thickness and IOP.


Subject(s)
Cornea , Elasticity Imaging Techniques/methods , Elasticity , Tomography, Optical Coherence/methods , Animals , Cattle , Models, Biological , Swine
7.
PLoS One ; 9(8): e104904, 2014.
Article in English | MEDLINE | ID: mdl-25121496

ABSTRACT

Biomechanical properties are an excellent health marker of biological tissues, however they are challenging to be measured in-vivo. Non-invasive approaches to assess tissue biomechanics have been suggested, but there is a clear need for more accurate techniques for diagnosis, surgical guidance and treatment evaluation. Recently air-puff systems have been developed to study the dynamic tissue response, nevertheless the experimental geometrical observations lack from an analysis that addresses specifically the inherent dynamic properties. In this study a viscoelastic finite element model was built that predicts the experimental corneal deformation response to an air-puff for different conditions. A sensitivity analysis reveals significant contributions to corneal deformation of intraocular pressure and corneal thickness, besides corneal biomechanical properties. The results show the capability of dynamic imaging to reveal inherent biomechanical properties in vivo. Estimates of corneal biomechanical parameters will contribute to the basic understanding of corneal structure, shape and integrity and increase the predictability of corneal surgery.


Subject(s)
Cornea/physiology , Air , Biomechanical Phenomena , Elasticity , Finite Element Analysis , Humans , Models, Theoretical , Viscosity
SELECTION OF CITATIONS