Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Rev. bras. oftalmol ; 82: e0043, 2023. tab, graf
Article in English | LILACS | ID: biblio-1507881

ABSTRACT

ABSTRACT LASIK is a refractive surgical procedure in which a corneal flap is created to expose the corneal stromal bed. Preoperative estimation of corneal flap thickness is necessary to calculate the percentage tissue altered in LASIK, an important quantitative risk factor for ectasia. The objective of this study was to assess flap thickness and calculate percentage tissue altered to check if unexpectedly thicker flaps and higher percentage tissue altered could pose as risk factors of ectasia. Four subjects (eight eyes) were submitted to mechanical LASIK in 2009 and 2010. Pre and postoperative clinical and tomographic data were reviewed. Mean preoperative estimated percentage tissue altered was 39.18±1.31%, which was borderline for increased ectasia risk when considering the limit of 40%. However, when considering the postoperatively measured flap thickness, the actual mean percentage tissue altered turned out to be 45.17 ± 4.13%, which was significantly higher than predicted preoperatively (p=0.002). Unexpectedly higher postoperative percentage tissue altered may be responsible for corneal ectasia after mechanical LASIK.


RESUMO A LASIK é um procedimento cirúrgico refrativo, no qual um retalho corneano é criado para expor o leito estromal corneano. A estimativa pré-operatória da espessura do retalho corneano é necessária para calcular o percentual de tecido alterado no LASIK, um importante fator de risco quantitativo para ectasia. O objetivo deste estudo foi avaliar a espessura do retalho e calcular o percentual de tecido alterado para verificar se retalhos inesperadamente mais espessos e percentuais de tecido alterado mais altos poderiam representar fatores de risco de ectasia. Quatro indivíduos (oito olhos) foram submetidos à LASIK mecânica em 2009 e 2010. Dados clínicos e tomográficos pré e pós-operatórios foram revisados. A média de percentual de tecido alterado pré-operatória estimada foi de 39,18±1,31%, limítrofe para risco aumentado de ectasia quando considerado o limite de 40%. No entanto, ao considerar a espessura do retalho medida no pós-operatório, o percentual de tecido alterado médio real foi de 45,17±4,13%, ou seja, significativamente maior do que o previsto no pré-operatório (p=0,002). O percentual de tecido alterado pós-operatóriao inesperadamente mais alto pode ser responsável pela ectasia da córnea após LASIK mecânico.


Subject(s)
Humans , Male , Female , Adult , Postoperative Complications , Surgical Flaps/pathology , Keratomileusis, Laser In Situ/adverse effects , Keratomileusis, Laser In Situ/methods , Dilatation, Pathologic/etiology , Lasers, Excimer/adverse effects , Refractive Errors , Cornea/surgery , Cornea/pathology , Corneal Topography/methods , Tomography, Optical Coherence , Dilatation, Pathologic/diagnosis , Refractive Surgical Procedures/methods , Lasers, Excimer/therapeutic use
2.
Retin Cases Brief Rep ; 14(1): 61-65, 2020.
Article in English | MEDLINE | ID: mdl-28799971

ABSTRACT

PURPOSE: Congenital retinal macrovessels are large aberrant retinal blood vessels that cross the horizontal raphe and can traverse the central macula. Using multimodal imaging and optical coherence tomography angiography, we describe 2 cases of congenital retinal macrovessel associated with macroaneurysms. METHODS: Two patients presented for evaluation and were found to have congenital retinal macrovessels associated with macroaneurysms. Color photography, optical coherence tomography, fundus autofluorescence fluorescein angiography, and optical coherence tomography angiography were performed and used to establish the diagnosis and monitor resolution at follow-up visits. RESULTS: The first patient presented with central vision loss in the right eye and was noted to have a ruptured macroaneurysm and scattered microaneurysms along the course of a venous macrovessel. After 3 months of observation, the patient's vision improved. The second patient presented for evaluation of a cataract in her left eye and was incidentally found to have an arterial macrovessel in her right eye with an associated macroaneurysm. Both cases demonstrated an intricate capillary network in the central macula best visualized on optical coherence tomography angiography. CONCLUSION: Macroaneurysms can occur on both arterial and venous macrovessels. After rupture of these lesions, hemorrhage and exudation can resolve with observation alone. Macrovessels can also present with microaneurysms. Optical coherence tomography angiography can effectively image the complex capillary network associated with these vascular anomalies.


Subject(s)
Aneurysm/diagnosis , Fluorescein Angiography/methods , Retinal Artery/abnormalities , Tomography, Optical Coherence/methods , Vascular Malformations/complications , Visual Acuity , Aneurysm/etiology , Female , Fundus Oculi , Humans , Middle Aged , Retinal Artery/pathology , Vascular Malformations/diagnosis
3.
Ophthalmologica ; 241(4): 202-210, 2019.
Article in English | MEDLINE | ID: mdl-30332674

ABSTRACT

OBJECTIVE: To compare two different laser strategies of panretinal photocoagulation for diabetic retinopathy. METHODS: Single-center, randomized study including 41 eyes treated with 577-nm multispot laser with a 20-ms pulse duration (group 1) or a 532-nm single-spot laser with a 100-ms pulse duration (group 2). The outcomes included best-corrected visual acuity (BCVA) and imaging changes at baseline, 6 and 12 months, laser parameters, and results of subjective pain analysis. RESULTS: At 12 months, the treatments did not differ significantly in BCVA, central retinal thicknesses (CRTs), improved macular edema, vitreomacular interface changes, patient-reported pain scores, or angiographic responses. Group 1 had significantly fewer treatment sessions but used more laser spots (p < 0.001). CONCLUSION: The multispot laser required fewer applications with more spots delivered to compensate for lower fluency, showing similar patient tolerance to single-spot laser. Both groups maintained the initial visual acuities and CRTs; about 50% of cases had vitreomacular interface changes and improved macular edema, with similar angiographic improvements after 12 months.


Subject(s)
Diabetic Retinopathy/surgery , Laser Coagulation/methods , Retina/surgery , Visual Acuity , Diabetic Retinopathy/diagnosis , Female , Fluorescein Angiography , Follow-Up Studies , Fundus Oculi , Humans , Male , Middle Aged , Prospective Studies , Retina/pathology , Tomography, Optical Coherence , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...