1.
JCI Insight ; 1(21): e90453, 2016 Dec 22.
Article in English | MEDLINE | ID: mdl-28018976

ABSTRACT

Three-dimensional cardiac mapping is important for optimal visualization of the heart during cardiac ablation for the treatment of certain arrhythmias. However, many hospitals and clinics worldwide cannot afford the high cost of the current mapping systems. We set out to determine if, using predefined algorithms, comparable 3D cardiac maps could be created by a new device that relies on data generated from single-plane fluoroscopy and patient recording and monitoring systems, without the need for costly equipment, infrastructure changes, or specialized catheters. The study included phantom and animal experiments to compare the prototype test device, Navik 3D, with the existing CARTO 3 System. The primary endpoint directly compared: (a) the 3D distance between the Navik 3D-simulated ablation location and the back-projected ground truth location of the pacing and mapping catheter electrode, and (b) the same distance for CARTO. The study's primary objective was considered met if the 95% confidence lower limit was greater than 0.75% for the Navik 3D-CARTO difference between the 2 distances, or less than or equal to 2 mm. Study results showed that the Navik 3D performance was equivalent to the CARTO system, and that accurate 3D cardiac maps can be created using data from equipment that already exists in all electrophysiology labs.

2.
J Atr Fibrillation ; 3(5): 250, 2011.
Article in English | MEDLINE | ID: mdl-28496684

ABSTRACT

Background: Dynamic motion of the heart due to cardiac and respiratory cycles, and rotation from varying patient positions between imaging modalities, can cause errors during cardiac image registration. This study used phantom, patient and animal models to assess and correct these errors. Methods and Results: Rotational errors were identified and corrected using different phantom orientations. ECG-gated fluoro images were aligned with similarly gated CT images in 9 patients, and accuracy assessed during atrial fibrillation (AF) and sinus rhythm. A tracking algorithm corrected errors due to respiration; 4 independent observers compared 25 respiration sequences to an automated method. Following correction of these errors, target registration error was assessed. At 20 mm and 30 mm from the phantom model's center point with an in-plane rotation of 8 degrees, measured error was 2.94 mm and 5.60 mm, respectively, and the main error identified. A priori method accurately predicted ECG location in only 38% (p=0.0003) of 313 R-R intervals in AF. A posteriori method accurately gated the ECG during AF and sinus rhythm in 97% and 98% of 375 beats evaluated, respectively (p=NS). Tracking algorithm for ECG-gated motion compensation was identified as good or fair 96% of the time, with no difference between observers and automated method (chi-square=25; p=NS). Target registration error in phantom and animal models was 1.75±1.03 mm and 0 to 0.5 mm, respectively. Conclusions: Errors during cardiac image registration can be identified and corrected. Cardiac image stabilization can be achieved using ECG gating and respiration.

3.
Proc SPIE Int Soc Opt Eng ; 6913: 69134U1-69134U8, 2008.
Article in English | MEDLINE | ID: mdl-19381355

ABSTRACT

The current x-ray source trajectory for C-arm based cone-beam CT is a single arc. Reconstruction from data acquired with this trajectory yields cone-beam artifacts for regions other than the central slice. In this work we present the preliminary evaluation of reconstruction from a source trajectory of two concentric arcs using a flat-panel detector equipped C-arm gantry (GE Healthcare Innova 4100 system, Waukesha, Wisconsin). The reconstruction method employed is a summation of FDK-type reconstructions from the two individual arcs. For the angle between arcs studied here, 30°, this method offers a significant reduction in the visibility of cone-beam artifacts, with the additional advantages of simplicity and ease of implementation due to the fact that it is a direct extension of the reconstruction method currently implemented on commercial systems. Reconstructed images from data acquired from the two arc trajectory are compared to those reconstructed from a single arc trajectory and evaluated in terms of spatial resolution, low contrast resolution, noise, and artifact level.

4.
Pediatr Radiol ; 36 Suppl 2: 204-11, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16862403

ABSTRACT

In this article, we present GE Healthcare's design philosophy and implementation of X-ray imaging systems with dose management for pediatric patients, as embodied in its current radiography and fluoroscopy and interventional cardiovascular X-ray product offerings. First, we present a basic framework of image quality and dose in the context of a cost-benefit trade-off, with the development of the concept of imaging dose efficiency. A set of key metrics of image quality and dose efficiency is presented, including X-ray source efficiency, detector quantum efficiency (DQE), detector dynamic range, and temporal response, with an explanation of the clinical relevance of each. Second, we present design methods for automatically selecting optimal X-ray technique parameters (kVp, mA, pulse width, and spectral filtration) in real time for various clinical applications. These methods are based on an optimization scheme where patient skin dose is minimized for a target desired image contrast-to-noise ratio. Operator display of skin dose and Dose-Area Product (DAP) is covered, as well. Third, system controls and predefined protocols available to the operator are explained in the context of dose management and the need to meet varying clinical procedure imaging demands. For example, fluoroscopic dose rate is adjustable over a range of 20:1 to adapt to different procedure requirements. Fourth, we discuss the impact of image processing techniques upon dose minimization. In particular, two such techniques, dynamic range compression through adaptive multiband spectral filtering and fluoroscopic noise reduction, are explored in some detail. Fifth, we review a list of system dose-reduction features, including automatic spectral filtration, virtual collimation, variable-rate pulsed fluoroscopic, grid and no-grid techniques, and fluoroscopic loop replay with store. In addition, we describe a new feature that automatically minimizes the patient-to-detector distance, along with an estimate of its dose reduction potential. Finally, two recently developed imaging techniques and their potential effect on dose utilization are discussed. Specifically, we discuss the dose benefits of rotational angiography and low frame rate imaging with advanced image processing in lieu of higher-dose digital subtraction.


Subject(s)
Environmental Exposure/prevention & control , Fluoroscopy/instrumentation , Pediatrics/instrumentation , Radiation Injuries/prevention & control , Radiation Protection/instrumentation , Radiography, Interventional/instrumentation , Body Burden , Equipment Design , Equipment Failure Analysis , Humans , Radiation Protection/methods , United States
5.
Circulation ; 112(24): 3763-8, 2005 Dec 13.
Article in English | MEDLINE | ID: mdl-16344405

ABSTRACT

BACKGROUND: Anatomic structures such as the left atrium and the pulmonary veins (PVs) are not delineated by fluoroscopy because there is no contrast differentiation between them and the surrounding anatomy. Representation of an anatomic structure via a 3D model obtained from computed tomography (CT) imaging and subsequent projection of these images over the fluoroscopy system may help in navigation of the mapping and ablation catheter to the appropriate sites during electrophysiology procedures. METHODS AND RESULTS: In this feasibility study, in vitro experiments were performed with a plastic heart model (phantom) with 2 catheters or radiopaque platinum beads placed in the phantom at the time of CT imaging and fluoroscopy. Subsequently, 20 consecutive patients underwent contrast-enhanced, ECG-gated CT scanning. Left atrial volumes were generated from the reconstructed data at &75% of the R-R interval during the cardiac cycle. Similarly, the superior vena cava and the coronary sinus were also reconstructed from these images. During the electrophysiology procedure, digital records (cine sequences) were obtained. Using predetermined algorithms, both the phantom model and the patients' 3D left atrial models derived from the CT were registered with projection images of fluoroscopy. Registration was performed with a transformation that linked the superior vena cava and the coronary sinus from the CT model with a catheter placed inside the coronary sinus via the superior vena cava. Registration was successfully accomplished with the plastic phantom and in all 20 patients. Registration accuracy was assessed in the phantom by assessing the overlapping beads seen both in the CT and the fluoroscopy images. The mean registration error was 1.4 mm (range 0.9 to 2.3 mm). Accuracy of the registered images was assessed in patients with recordings from a basket catheter placed sequentially in the superior PVs and by injecting contrast into the PVs to assess overlapping of contrast-filled PVs with the corresponding vessels on the registered images. The images could be calibrated quite accurately. Any rotational error, which was usually minor, could be corrected by rotating the images as needed. CONCLUSIONS: Registration of 3D models of the left atrium and PVs with fluoroscopic images of the same is feasible and could enable appropriate navigation and localization of the mapping and ablation catheter during procedures such as atrial fibrillation ablation.


Subject(s)
Diagnostic Imaging/methods , Heart Atria/anatomy & histology , Models, Cardiovascular , Aged , Algorithms , Cardiac Catheterization/methods , Contrast Media , Electrocardiography , Electrophysiologic Techniques, Cardiac , Feasibility Studies , Fluoroscopy/methods , Humans , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Male , Middle Aged , Phantoms, Imaging , Tomography, X-Ray Computed/methods