Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters










Publication year range
1.
Materials (Basel) ; 15(19)2022 Oct 05.
Article in English | MEDLINE | ID: mdl-36234241

ABSTRACT

This study aimed to investigate and compare the color stability and stainability of computer-aided design/computer-aided manufacturing (CAD/CAM) restorative materials in their glazed (G) and polished (P) state when exposed to cigarette smoke, as well as after brushing. Three CAD/CAM restorative materials were investigated: lithium disilicate CAD (LD), zirconia (Zr), and Telio PMMA CAD (PMMA), according to their surface finishing and assignment to cigarette smoking exposure or soaking in the saliva (control) group. The color change (∆E) was calculated before and after the intervention performed for all specimens, using the L*a*b values to quantitatively assess the shade differences. Statistical analysis was performed using one-way repeated measures ANOVA and Bonferroni multiple comparison analysis (α = 0.05). The surface finishing did not influence the materials' stainability. Color change was noted after smoking, LD and Zr-G and Zr-P had a comparable color change (p > 0.05), while PMMA presented lower ∆E values (p < 0.05). After brushing, all specimens had a significant color change that was high for LD-G and LD-P, and Zr-G, compared with Zr-P and PMMA (p < 0.05). In conclusion, the exposure to cigarette smoke showed that LD, Zr, and PMMA are all susceptible to staining, but brushing decreases surface staining.

2.
Mater Sci Eng C Mater Biol Appl ; 117: 111289, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32919650

ABSTRACT

Our goal was to create bio-functional chlorhexidine (CHX)-doped thin films on commercially pure titanium (cpTi) discs using the glow discharge plasma approach. Different plasma deposition times (50, 35 and 20 min) were used to create bio-functional surfaces based on silicon films with CHX that were compared to the control groups [no CHX and bulk cpTi surface (machined)]. Physico-chemical and biological characterizations included: 1. Morphology, roughness, elemental chemical composition, film thickness, contact angle and surface free energy; 2. CHX-release rate; 3. Antibacterial effect on Streptococcus sanguinis biofilms at 24, 48 and 72 h; 4. Cytotoxicity and metabolic activity using fibroblasts cell culture (NIH-F3T3 cells) at 1, 2, 3 and 4 days; 5. Protein expression by NIH-F3T3 cells at 1, 2, 3 and 4 days; and 6. Co-culture assay of fibroblasts cells and S. sanguinis to assess live and dead cells on the confocal laser scanning microscopy, mitochondrial activity (XTT), membrane leakage (LDH release), and metabolic activity (WST-1 assay) at 1, 2 and 3 days of co-incubation. Data analysis showed that silicon films, with or without CHX coated cpTi discs, increased surface wettability and free energy (p < 0.05) without affecting surface roughness. CHX release was maintained over a 22-day period and resulted in a significant inhibition of biofilm growth (p < 0.05) at 48 and 72 h of biofilm formation for 50 min and 20 min of plasma deposition time groups, respectively. In general, CHX treatment did not significantly affect NIH-F3T3 cell viability (p > 0.05), whereas cell metabolism (MTT assay) was affected by CHX, with the 35 min of plasma deposition time group displaying the lowest values as compared to bulk cpTi (p < 0.05). Moreover, data analysis showed that films, with or without CHX, significantly affected the expression profile of inflammatory cytokines, including IL-4, IL-6, IL-17, IFN-y and TNF-α by NIH-F3T3 cells (p < 0.05). Co-culture demonstrated that CHX-doped film did not affect the metabolic activity, cytotoxicity and viability of fibroblasts cells (p > 0.05). Altogether, the findings of the current study support the conclusion that silicon films added with CHX can be successfully created on titanium discs and have the potential to affect bacterial growth and inflammatory markers without affecting cell viability/proliferation rates.


Subject(s)
Chlorhexidine , Titanium , Biofilms , Chlorhexidine/pharmacology , Streptococcus sanguis , Surface Properties
3.
Mater Sci Eng C Mater Biol Appl ; 101: 111-119, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31029304

ABSTRACT

The aim of this study was to tailor the deposition parameters of magnetron sputtering to synthetize tantalum oxide (TaxOy) films onto commercially pure titanium (cpTi) surface. The structural and optical properties, morphology, roughness, elemental chemical composition and surface energy were assessed. The impact of TaxOy films on initial Streptococcus sanguinis adhesion was investigated. The morphology and spreading of pre-osteoblastic (MC3T3-E1) cells on a crystalline tantalum oxide film were evaluated. TaxOy films with estimated thickness of 600 nm and different structures (amorphous or crystalline) were produced depending on the various oxygen flow rates and parameters used. X-ray diffraction analysis revealed that the 8 O2 sccm (600 °C/400 W) group showed crystallization corresponding to the ß-Ta2O5 phase. Optical analysis showed that the 4 O2 sccm (200 °C 300 W) to 8 O2 sccm (600 °C 300 W) groups and 10 O2 sccm (200 °C 300 W) group presented regular and large-amplitude interference oscillations, suggesting high optical homogeneity of the films. The crystalline ß-Ta2O5 coating showed higher roughness and surface energy values than the other groups (P < .05) and was biocompatible. Compared with cpTi, the amorphous and crystalline tantalum oxide films did not increase bacterial adhesion (P > .05). By tailoring the deposition parameters, we synthetized a crystalline ß-Ta2O5 coating that improved titanium surface properties and positively affected cell spreading and morphology, making it a promising surface treatment for titanium-based implants.


Subject(s)
Biocompatible Materials/chemistry , Biomedical Technology/methods , Tantalum/chemistry , Animals , Cell Line , Coated Materials, Biocompatible/chemistry , Mice , Osteoblasts/cytology , Osteoblasts/ultrastructure , Refractometry , Thermodynamics , X-Ray Diffraction
4.
J Prosthet Dent ; 120(2): 290-298, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29551382

ABSTRACT

STATEMENT OF PROBLEM: Biofilms can reduce the corrosion resistance of titanium because of the bacterial metabolism of fermentable carbohydrates, including sucrose. However, studies evaluating whether biofilms exposed to higher sucrose concentrations can affect the electrochemical behavior of titanium are lacking. PURPOSE: The purpose of this in vitro study was to test the electrochemical behavior of titanium previously exposed to biofilm supplemented with different sucrose concentrations. MATERIAL AND METHODS: Streptococcus mutans UA159 biofilms were formed on commercially pure titanium (cpTi) surfaces and supplemented constantly with different sucrose concentrations (0%, 1%, 10%, and 40%) for 7 days (experimental groups) (n=12 per group). CpTi disks without biofilm were used as a control (n=12). The standard electrochemical tests open-circuit potential, electrochemical impedance spectroscopy, and potentiodynamic curve were performed. Data were submitted to ANOVA and the Tukey honestly significant difference (HSD) tests (α=.05). RESULTS: The biofilm exposed to sucrose had an increased biofilm dry weight (P<.05). The polysaccharide amount and the pH drop were higher in the groups exposed to sucrose (P<.05). No difference was noted between the control and experimental groups for the electrochemical properties of cpTi (P>.05). CONCLUSIONS: Biofilms exposed to greater carbohydrate concentration did not alter the corrosive behavior of titanium.


Subject(s)
Biofilms , Electrochemistry , Materials Testing , Sucrose/metabolism , Titanium/chemistry , Biofilms/growth & development , Corrosion , Dental Implants , Dental Materials/chemistry , Dielectric Spectroscopy , Electrochemical Techniques , Hydrogen-Ion Concentration , Polysaccharides/chemistry , Saliva, Artificial , Streptococcus mutans/growth & development , Streptococcus mutans/metabolism , Surface Properties , Time Factors
5.
J Prosthodont ; 27(2): 169-176, 2018 Feb.
Article in English | MEDLINE | ID: mdl-26999386

ABSTRACT

PURPOSE: Denture tooth debonding is a common complication for denture wearers; however, the effect of complete denture disinfection on bonding between denture teeth and acrylic resin remains unclear. The aim of this study was to evaluate the effect of disinfection methods on the bond strength between denture teeth and microwave-cured acrylic resin denture base. MATERIALS AND METHODS: Three commercial brands of denture teeth (Trilux, Biolux, Vipi Dent Plus) and one microwave-cured acrylic resin denture base were tested. Each brand of denture teeth was divided into seven groups (n = 6; estimated by partial Eta squared). The specimenss of groups H and Cl were immersed in 1% sodium hypochlorite and 4% chlorhexidine digluconate for 7 days, respectively. In group Br, the specimens were subjected to toothbrush simulation under 200 g of force for 20,000 cycles. In groups Br-H and Br-Cl, the specimens were brushed and further disinfected with 1% sodium hypochlorite and 4% chlorhexidine digluconate, respectively. In control groups 1 (Co1) and 2 (Co2), the specimens were stored in distilled water for 50 ± 2 hours and 7 days, respectively. Shear bond strength testing was performed at the resin/tooth interface in a universal testing machine at a 1 mm/min crosshead speed. The failure pattern was quantified and classified into adhesive, cohesive, or mixed. Data were analyzed using two-way ANOVA and Tukey HSD test (α = 0.05). RESULTS: Disinfection with 1% sodium hypochlorite (p = 0.031), brushing (p < 0.0001), and association of brushing with either 1% sodium hypochlorite (p < 0.0001) or 4% chlorhexidine digluconate (p = 0.01) reduced the bond strength between denture teeth and microwave-cured acrylic resin denture base. All commercial brands of denture teeth presented a similar bond strength (p > 0.05). The failure pattern was predominantly adhesive independent of the disinfection method and denture tooth brand. CONCLUSIONS: Disinfection with sodium hypochlorite, brushing, and the association of mechanical and chemical methods reduced the bond strength between denture tooth and microwave-cured acrylic resin denture base.


Subject(s)
Acrylic Resins/therapeutic use , Dental Bonding , Denture Bases , Dentures , Disinfectants/adverse effects , Sodium Hypochlorite/adverse effects , Acrylic Resins/adverse effects , Dental Stress Analysis , Disinfection/methods , Humans , Microwaves/therapeutic use
6.
J Prosthet Dent ; 119(1): 185-192, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28533010

ABSTRACT

STATEMENT OF PROBLEM: Although craniofacial implants have been used for retention of facial prostheses, failures are common. Titanium undergoes corrosion in the oral cavity, but the corrosion of craniofacial implants requires evaluation. PURPOSE: The purpose of this in vitro study was to investigate the corrosion stability of commercially pure titanium (CP Ti) exposed to simulated human perspiration at 2 different pH levels (5.5 and 8). MATERIAL AND METHODS: Fifteen titanium disks were divided into 3 groups (n=5 per group). The control group was subjected to simulated body fluid (SBF) (control). Disks from the 2 experimental groups were immersed in simulated alkaline perspiration (SAKP) and simulated acidic perspiration (SACP). Electrochemical tests, including open circuit potential (3600 seconds), electrochemical impedance spectroscopy, and potentiodynamic tests were performed according to the standardized method of 3-cell electrodes. Data were analyzed by 1-way ANOVA and the Tukey honestly significant difference tests (α=.05). RESULTS: Simulated human perspiration reduced the corrosion stability of CP Ti (P<.05). The SBF group presented the lowest capacitance values (P<.05). SAKP and SACP groups showed increased values of capacitance and showed no statistically significant differences (P>.05) from each other. The increase in capacitance suggests that the acceleration of the ionic exchanges between the CP Ti and the electrolyte leads to a lower corrosion resistance. SAKP reduced the oxide layer resistance of CP Ti (P<.05), and an increased corrosion rate was noted in both simulated human perspiration groups. CONCLUSIONS: Craniofacial implants can corrode when in contact with simulated human perspiration, whereas alkaline perspiration shows a more deleterious effect. Perspiration induces a more corrosive effect than simulated body fluid.


Subject(s)
Facial Bones/surgery , Prostheses and Implants , Skull/surgery , Titanium , Corrosion , Materials Testing , Prosthesis Design
7.
Dent Mater ; 33(11): 1244-1257, 2017 11.
Article in English | MEDLINE | ID: mdl-28778495

ABSTRACT

OBJECTIVE: The aim of this study was to develop binary and ternary titanium (Ti) alloys containing zirconium (Zr) and niobium (Nb) and to characterize them in terms of microstructural, mechanical, chemical, electrochemical, and biological properties. METHODS: The experimental alloys - (in wt%) Ti-5Zr, Ti-10Zr, Ti-35Nb-5Zr, and Ti-35Nb-10Zr - were fabricated from pure metals. Commercially pure titanium (cpTi) and Ti-6Al-4V were used as controls. Microstructural analysis was performed by means of X-ray diffraction and scanning electron microscopy. Vickers microhardness, elastic modulus, dispersive energy spectroscopy, X-ray excited photoelectron spectroscopy, atomic force microscopy, surface roughness, and surface free energy were evaluated. The electrochemical behavior analysis was conducted in a body fluid solution (pH 7.4). The albumin adsorption was measured by the bicinchoninic acid method. Data were evaluated through one-way ANOVA and the Tukey test (α=0.05). RESULTS: The alloying elements proved to modify the alloy microstructure and to enhance the mechanical properties, improving the hardness and decreasing the elastic modulus of the binary and ternary alloys, respectively. Ti-Zr alloys displayed greater electrochemical stability relative to that of controls, presenting higher polarization resistance and lower capacitance. The experimental alloys were not detrimental to albumin adsorption. SIGNIFICANCE: The experimental alloys are suitable options for dental implant manufacturing, particularly the binary system, which showed a better combination of mechanical and electrochemical properties without the presence of toxic elements.


Subject(s)
Dental Alloys/chemical synthesis , Dental Implants , Niobium/chemistry , Titanium/chemistry , Zirconium/chemistry , Albumins/chemistry , Biocompatible Materials/chemical synthesis , Elastic Modulus , Electrochemistry , Hardness , Materials Testing , Microscopy, Atomic Force , Microscopy, Electron, Scanning , Photoelectron Spectroscopy , Spectrometry, X-Ray Emission , X-Ray Diffraction
8.
Colloids Surf B Biointerfaces ; 152: 354-366, 2017 Apr 01.
Article in English | MEDLINE | ID: mdl-28131960

ABSTRACT

In this study, titanium (Ti) was modified with biofunctional and novel surface by micro-arc oxidation (MAO) and glow discharge plasma (GDP) and we tested the development of a three-species periodontopatogenic biofilm onto the treated commercially-pure titanium (cpTi) surfaces. Machined and sandblasted surfaces were used as control group. Several techniques for surface characterizations and monoculture on bone tissue cells were performed. A multispecies biofilm composed of Streptococcus sanguinis, Actinomyces naeslundii and Fusobacterium nucleatum was developed onto cpTi discs for 16.5h (early biofilm) and 64.5h (mature biofilm). The number of viable microorganisms and the composition of the extracellular matrix (proteins and carbohydrates) were determined. The biofilm organization was analyzed by scanning electron microscopy (SEM) and Confocal laser scanning microscopy (CLSM). In addition, MC3T3-E1 cells were cultured on the Ti surfaces and cell proliferation (MTT) and morphology (SEM) were assessed. MAO treatment produced oxide films rich in calcium and phosphorus with a volcano appearance while GDP treatment produced silicon-based smooth thin-film. Plasma treatments were able to increase the wettability of cpTi (p<0.05). An increase of surface roughness (p<0.05) and formation of anatase and rutile structures was noted after MAO treatment. GDP had the greatest surface free energy (p<0.05) while maintaining the surface roughness compared to the machined control (p>0.05). Plasma treatment did not affect the viable microorganisms counts, but the counts of F. nucleatum was lower for MAO treatment at early biofilm phase. Biofilm extracellular matrix was similar among the groups, excepted for GDP that presented the lowest protein content. Moreover, cell proliferation was not significantly affected by the experimental, except for MAO at 6days that resulted in an increased cell proliferative. Together, these findings indicate that plasma treatments are a viable and promising technology to treat bone-integrated dental implants as the new surfaces displayed improved mechanical and biological properties with no increase in biofilm proliferation.


Subject(s)
Biocompatible Materials , Biofilms/growth & development , Titanium/chemistry , Actinomyces/growth & development , Animals , Bacterial Adhesion , Cell Line , Dental Implants/microbiology , Fusobacterium nucleatum/growth & development , Mice , Microscopy, Atomic Force , Microscopy, Confocal , Microscopy, Electron, Scanning , Oxidation-Reduction , Streptococcus sanguis/growth & development , Surface Properties
9.
Cien Saude Colet ; 21(7): 2201-8, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27383353

ABSTRACT

Panoramic radiographs (PR) can display radiopaque images suggestive of calcified atheroma in the carotid artery in asymptomatic patients. The aim of this study was to evaluate the prevalence of these images on PR and their linkage with hypertension, obesity, age, gender and smoking habits. PR of 505 patients were evaluated. They were older than 30 years old and their PR had been taken for different clinical reasons. Their body mass index was calculated; their waist circumference was also taken into consideration. Information about smoking habits and hypertension was obtained. The observers analyzed the presence of radiopaque mass in the region of the cervical vertebrae C3-C4 through the PR, confirmed by an antero-posterior (AP) radiograph. The results showed a 7.92% prevalence of suggestive images of calcifications on PR and on AP radiograph. The adjusted Odds Ratio showed association with age and smoking habits. The calcification process is almost nine times higher for the elderly when compared to the young. As far as smokers are concerned, this process is twice worse when compared to no smokers. In conclusion, 7.92% of the group studied presented suggestive images of carotid atherosclerosis on PR, which is directly associated with the age and smoking habits.


Subject(s)
Carotid Artery Diseases/diagnostic imaging , Vascular Calcification/diagnostic imaging , Adult , Aged , Aged, 80 and over , Angiography/methods , Cardiovascular Diseases/complications , Carotid Artery Diseases/epidemiology , Carotid Artery Diseases/etiology , Causality , Female , Humans , Hypertension/complications , Male , Middle Aged , Obesity/complications , Prevalence , Radiography, Panoramic , Sex Factors , Smoking/adverse effects , Vascular Calcification/epidemiology , Vascular Calcification/etiology
10.
Ciênc. Saúde Colet. (Impr.) ; 21(7): 2201-2208, Jul. 2016. tab, graf
Article in English | LILACS | ID: lil-785900

ABSTRACT

Abstract Panoramic radiographs (PR) can display radiopaque images suggestive of calcified atheroma in the carotid artery in asymptomatic patients. The aim of this study was to evaluate the prevalence of these images on PR and their linkage with hypertension, obesity, age, gender and smoking habits. PR of 505 patients were evaluated. They were older than 30 years old and their PR had been taken for different clinical reasons. Their body mass index was calculated; their waist circumference was also taken into consideration. Information about smoking habits and hypertension was obtained. The observers analyzed the presence of radiopaque mass in the region of the cervical vertebrae C3-C4 through the PR, confirmed by an antero-posterior (AP) radiograph. The results showed a 7.92% prevalence of suggestive images of calcifications on PR and on AP radiograph. The adjusted Odds Ratio showed association with age and smoking habits. The calcification process is almost nine times higher for the elderly when compared to the young. As far as smokers are concerned, this process is twice worse when compared to no smokers. In conclusion, 7.92% of the group studied presented suggestive images of carotid atherosclerosis on PR, which is directly associated with the age and smoking habits.


Resumo As radiografias panorâmicas (RP) podem exibir imagens radiopacas sugestivas de ateromas calcificados na artéria carótida em pacientes assintomáticos. O objetivo deste estudo foi avaliar a prevalência destas imagens na RP e sua relação com hipertensão, obesidade, idade, sexo e tabagismo. Foram avaliadas RP de 505 pacientes acima de trinta anos, que realizaram esse exame por diversos motivos clínicos. Seu índice de massa corpórea foi calculado; sua circunferência abdominal também foi considerada. Informações sobre hipertensão e tabagismo foram obtidas. Os observadores avaliaram as RP para a presença de massas radiopacas na região das vértebras cervicais C3-C4, confirmadas por meio de uma radiografia ântero-posterior (AP). Os resultados mostraram prevalência de 7,92% de imagens sugestivas de calcificações em RP e na radiografia AP. A razão de probabilidade (OR) ajustada mostrou associação com idade e tabagismo. O risco para as pessoas mais velhas aumenta até cerca de nove vezes quando comparado com aqueles mais jovens, enquanto para os fumantes, o risco é o dobro, quando comparado com não fumantes. Na população estudada, 7,92% de todos os sujeitos apresentaram imagens sugestivas de aterosclerose carotídea em RP e houve associação com idade e tabagismo.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Carotid Artery Diseases/etiology , Carotid Artery Diseases/epidemiology , Carotid Artery Diseases/diagnostic imaging , Vascular Calcification/etiology , Vascular Calcification/epidemiology , Vascular Calcification/diagnostic imaging , Angiography/methods , Radiography, Panoramic , Cardiovascular Diseases/complications , Smoking/adverse effects , Sex Factors , Prevalence , Causality , Hypertension/complications , Obesity/complications
12.
Biointerphases ; 11(1): 011013, 2016 Mar 16.
Article in English | MEDLINE | ID: mdl-26984234

ABSTRACT

In this study, the authors tested the hypotheses that plasma electrolytic oxidation (PEO) and glow-discharge plasma (GDP) would improve the electrochemical, physical, chemical, and mechanical properties of commercially pure titanium (cpTi), and that blood protein adsorption on plasma-treated surfaces would increase. Machined and sandblasted surfaces were used as controls. Standard electrochemical tests were conducted in artificial saliva (pHs of 3.0, 6.5, and 9.0) and simulated body fluid. Surfaces were characterized by scanning electron microscopy, energy-dispersive spectroscopy, x-ray photoelectron spectroscopy, atomic force microscopy, x-ray diffraction, profilometry, Vickers microhardness, and surface energy. For biological assay, the adsorption of blood serum proteins (i.e., albumin, fibrinogen, and fibronectin) was tested. Higher values of polarization resistance and lower values of capacitance were noted for the PEO and GDP groups (p < 0.05). Acidic artificial saliva reduced the corrosion resistance of cpTi (p < 0.05). PEO and GDP treatments improved the surface properties by enrichment of the surface chemistry with bioactive elements and increased surface energy. PEO produced a porous oxide layer (5-µm thickness), while GDP created a very thin oxide layer (0.76-µm thickness). For the PEO group, the authors noted rutile and anatase crystalline structures that may be responsible for the corrosion barrier improvement and increased microhardness values. Plasma treatments were able to enhance the surface properties and electrochemical stability of titanium, while increasing protein adsorption levels.


Subject(s)
Biocompatible Materials/chemistry , Surface Properties , Titanium/chemistry , Blood Proteins/metabolism , Electrolysis , Microscopy, Atomic Force , Microscopy, Electron, Scanning , Oxidation-Reduction , Photoelectron Spectroscopy , Plasma Gases , Protein Binding , Spectrometry, X-Ray Emission , X-Ray Diffraction
13.
Mater Sci Eng C Mater Biol Appl ; 59: 1079-1088, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26652467

ABSTRACT

The role of surface treatment on the electrochemical behavior of commercially pure titanium (cpTi) exposed to mouthwashes was tested. Seventy-five disks were divided into 15 groups according to surface treatment (machined, sand blasted with Al2O3, and acid etched) and electrolyte solution (artificial saliva ­ control, 0.12% chlorhexidine digluconate, 0.05% cetylpyridinium chloride, 0.2% sodium fluoride, and 1.5% hydrogen peroxide) (n = 5). Open-circuit-potential and electrochemical impedance spectroscopy were conducted at baseline and after 7 and 14 days of immersion in each solution. Potentiodynamic test and total weight loss of disks were performed after 14 days of immersion. Scanning electron microscopy, energy dispersive spectroscopy, white light interferometry and profilometry were conducted for surface characterization before and after the electrochemical tests. Sandblasting promoted the lowest polarization resistance (Rp) (P b .0001) and the highest capacitance (CPE) (P b .006), corrosion current density (Icorr) and corrosion rate (P b .0001). In contrast, acid etching increased Rp and reduced CPE, independent to the mouthwash; while hydrogen peroxide reduced Rp (P b .008) and increased Icorr and corrosion rate (P b .0001). The highest CPE values were found for hydrogen peroxide and 0.2% sodium fluoride. Immersion for longer period improved the electrochemical stability of cpTi (P b .05). In conclusion, acid etching enhanced the electrochemical stability of cpTi. Hydrogen peroxide and sodium fluoride reduced the resistance to corrosion of cpTi, independent to the surface treatment. Chlorhexidine gluconate and cetylpyridinium chloride did not alter the corrosive behavior of cpTi.


Subject(s)
Mouthwashes/chemistry , Titanium/chemistry , Corrosion , Electrochemistry , Hydrogen Peroxide/chemistry , Saliva, Artificial/chemistry , Sodium Fluoride/chemistry , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...