Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Br J Radiol ; 86(1021): 20120135, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23255537

ABSTRACT

OBJECTIVE: The aim of this study was to investigate the use of dental cone beam CT (CBCT) grey values for density estimations by calculating the correlation with multislice CT (MSCT) values and the grey value error after recalibration. METHODS: A polymethyl methacrylate (PMMA) phantom was developed containing inserts of different density: air, PMMA, hydroxyapatite (HA) 50 mg cm(-3), HA 100, HA 200 and aluminium. The phantom was scanned on 13 CBCT devices and 1 MSCT device. Correlation between CBCT grey values and CT numbers was calculated, and the average error of the CBCT values was estimated in the medium-density range after recalibration. RESULTS: Pearson correlation coefficients ranged between 0.7014 and 0.9996 in the full-density range and between 0.5620 and 0.9991 in the medium-density range. The average error of CBCT voxel values in the medium-density range was between 35 and 1562. CONCLUSION: Even though most CBCT devices showed a good overall correlation with CT numbers, large errors can be seen when using the grey values in a quantitative way. Although it could be possible to obtain pseudo-Hounsfield units from certain CBCTs, alternative methods of assessing bone tissue should be further investigated. ADVANCES IN KNOWLEDGE: The suitability of dental CBCT for density estimations was assessed, involving a large number of devices and protocols. The possibility for grey value calibration was thoroughly investigated.


Subject(s)
Absorptiometry, Photon/methods , Bone Density , Cone-Beam Computed Tomography/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dental/methods , Tooth/diagnostic imaging , Absorptiometry, Photon/instrumentation , Cone-Beam Computed Tomography/instrumentation , Humans , Phantoms, Imaging , Radiography, Dental/instrumentation , Reproducibility of Results , Sensitivity and Specificity
2.
J Radiol ; 73(1): 23-33, 1992 Jan.
Article in French | MEDLINE | ID: mdl-1545411

ABSTRACT

The authors report their experience and method for computed tomography of maxilla and mandible before endosseous implant surgery. CT defines indications of implant surgery, avoiding useless operations and sometimes allowing implant surgery that seemed impossible on standard X-rays. It provides good preoperative assessment, precising diameter and length of implant, exact location and state of anatomic structures to be avoided, quality of bone and ideal implant axis.


Subject(s)
Dental Implantation, Endosseous , Tomography, X-Ray Computed , Adolescent , Adult , Aged , Aged, 80 and over , Bone Density , Female , Humans , Male , Mandible/diagnostic imaging , Maxilla/diagnostic imaging , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...