Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 73
Filter
1.
EJNMMI Res ; 14(1): 52, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38809472

ABSTRACT

BACKGROUND: F-18-flurodeoxyglucose (FDG) PET/CT is routinely used for staging, evaluation of response to treatment and follow-up of most pediatric malignancies. Cervical lymph nodes can be involved in some pediatric malignancies, but increased uptake in non-malignant cervical lymph nodes is not exceptional in this population. The aim of the present study is to identify predictors of the maximum uptake in non-malignant cervical lymph nodes in the pediatric population. METHODS: 191 FDG PET/CT studies of pediatric patients without malignant involvement of cervical lymph nodes were retrospectively reviewed. The maximal Standard Uptake Value in the hottest cervical lymph node (SUVmaxCLN), as well as demographic, technical and imaging variables were recorded. The predictive effect of those variables on SUVmaxCLN was estimated using linear regression models. RESULTS: Increased FDG activity in cervical nodes was observed in 136/191 studies (71%). The mean SUVmaxCLN was 2.2 ± 1.3. Ipsilateral palatine tonsil SUVmax, mean liver uptake, and treatment status were all statistically significant predictors of SUVmaxCLN. However, in multivariate regression analysis, only ipsilateral palatine tonsil SUVmax was found to be significant. In addition, SUVmaxCLN was greater than the mean liver uptake in 50% of all studies. This proportion was higher in younger children, reaching 77% of studies of children younger than six years. CONCLUSION: SUVmax in ipsilateral palatine tonsil is a strong predictor of the maximal uptake value of non-malignant cervical lymph nodes in children. The intensity of uptake in non-malignant cervical lymph nodes is frequently higher than liver uptake in children, and this tendency increases for younger patients. TRIAL WAS REGISTERED: In the internal hospital registry under TRN 0209-22-HMO on date 23.04.2022.

2.
PET Clin ; 19(3): 389-399, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38679550

ABSTRACT

Prostate cancer is the most common malignancy in men worldwide, with an estimated 174,650 new cases per year in the United States, and the second cancer-related cause of death, after lung cancer, with 31,620 deaths per year. While the 5 year survival rate for prostate cancer in patients without metastatic spread is nearly 100%, those with distant metastases have 5 year survival rates of approximately 30%. Initial diagnosis and assessment are based on PSA levels, Gleason score (derived from prostate biopsy), and advanced imaging modalities, including prostate MR imaging and PSMA-PET/computed tomography in patients with high-risk features.


Subject(s)
Prostatic Neoplasms , Radiopharmaceuticals , Humans , Male , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/pathology , Radiopharmaceuticals/therapeutic use , Positron Emission Tomography Computed Tomography/methods , Beta Particles/therapeutic use
3.
J Neurol Sci ; 459: 122983, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38574438

ABSTRACT

Acute midbrain injury may cause both hyperkinetic movement disorders and parkinsonism. The temporal interval between the insult and the emergence of hyperkinetic disorders can last years. A delayed appearance of parkinsonism, on the other hand, was rarely described. We present three cases of male patients (50-, 58- and 28-year-old) who developed levodopa-responsive parkinsonism 20, 8 and two years, respectively, after acute brain insult involving the midbrain. Insults included subcortical intracerebral hemorrhage dissecting into the midbrain, embolic basilar occlusion and trauma. A fluorodopa scan, performed in two cases, revealed reduced striatal uptake. All individuals improved on low doses of levodopa and developed motor fluctuations shortly after levodopa was introduced. We conclude that delayed, levodopa-responsive parkinsonism following midbrain injury should be recognized in the relevant clinical setup. Possible mechanisms include age-related loss of dopaminergic neurons superimposed on acute injury and secondary neurodegeneration.


Subject(s)
Levodopa , Parkinsonian Disorders , Humans , Male , Levodopa/adverse effects , Parkinsonian Disorders/complications , Parkinsonian Disorders/diagnostic imaging , Parkinsonian Disorders/drug therapy , Brain , Mesencephalon/diagnostic imaging , Corpus Striatum
4.
Eur J Nucl Med Mol Imaging ; 51(8): 2320-2331, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38453729

ABSTRACT

PURPOSE: The recent development and approval of new diagnostic imaging and therapy approaches in the field of theranostics have revolutionised nuclear medicine practice. To ensure the provision of these new imaging and therapy approaches in a safe and high-quality manner, training of nuclear medicine physicians and qualified specialists is paramount. This is required for trainees who are learning theranostics practice, and for ensuring minimum standards for knowledge and competency in existing practising specialists. METHODS: To address the need for a training curriculum in theranostics that would be utilised at a global level, a Consultancy Meeting was held at the IAEA in May 2023, with participation by experts in radiopharmaceutical therapy and theranostics including representatives of major international organisations relevant to theranostics practice. RESULTS: Through extensive discussions and review of existing curriculum and guidelines, a harmonised training program for theranostics was developed, which aims to ensure safe and high quality theranostics practice in all countries. CONCLUSION: The guiding principles for theranostics training outlined in this paper have immediate relevance for the safe and effective practice of theranostics.


Subject(s)
Nuclear Medicine , Humans , Nuclear Medicine/education , Theranostic Nanomedicine , Curriculum
6.
J Nucl Med ; 64(10): 1610-1616, 2023 10.
Article in English | MEDLINE | ID: mdl-37500259

ABSTRACT

Dosimetry after 177Lu-DOTATATE peptide receptor radionuclide therapy (PRRT) enables estimation of radiation doses absorbed by normal organs and target lesions. This process is time-consuming and requires multiple posttreatment studies on several subsequent days. In a previous study, we described a newly developed multiple-linear-regression model to predict absorbed doses (ADs) from a single-time-point (STP) posttreatment study acquired 168 h after the first infusion and 24 h after the following ones, with similar results to the standard multiple-time-point (MTP) protocol. The present study aimed to validate this model in a large patient cohort and to assess whether STP dosimetry affects patient management decisions compared with our MTP protocol. Methods: Quantitative 177Lu-DOTATATE SPECT/CT post-PRRT data from 159 consecutive patients (172 therapies, 477 therapy cycles) were retrospectively analyzed. ADs obtained from an STP model were compared with those obtained using an MTP model. We evaluated the impact of the STP model on the decision on whether PRRT should be stopped because of an expected kidney AD exceeding the safety threshold. We hypothesized that patient management based on the STP model does not differ from that based on the MTP model in at least 90% of the cases. Results: There was no difference in management decisions between the MTP and STP models in 170 of 172 therapies (98.8%). A Fisher χ2 test for combined probabilities produced a composite P value of 0.0003. Mean cumulative AD relative differences between the STP and MTP models were 0.8% ± 8.0%, -7.7% ± 4.8%, 0.0% ± 11.4%, -2.8% ± 6.3%, and -2.1% ± 18.4% for kidneys, bone marrow, liver, spleen, and tumors, respectively (Pearson r = 0.99 for all), for patients who underwent 4 therapy cycles. Similar results were obtained with fewer therapy cycles. Conclusion: Estimated radiation ADs and patient management decisions were similar with the STP and MTP models. The STP model can simplify the dosimetry process while also reducing scanner and staff time and improving patient comfort.


Subject(s)
Neuroendocrine Tumors , Organometallic Compounds , Humans , Retrospective Studies , Octreotide/adverse effects , Radiometry , Kidney , Single Photon Emission Computed Tomography Computed Tomography , Neuroendocrine Tumors/radiotherapy , Neuroendocrine Tumors/drug therapy , Organometallic Compounds/therapeutic use
7.
EJNMMI Phys ; 10(1): 5, 2023 Jan 23.
Article in English | MEDLINE | ID: mdl-36689080

ABSTRACT

BACKGROUND: Conventional calibration of the gamma camera consists of the calculation of calibration factors (CFs) (ratio of counts/cc and true concentration activity) as the function of the volume of interest (VOI). However, such method shows inconsistent results when the background activity varies. The aim of the present study was to propose a new calibration method by considering the sphere-to-background counts/voxel ratio (SBVR) in addition to the VOI for CFs calculation. A PET cylindrical flood phantom, a NEMA IQ body phantom, a Data spectrum Torso Phantom (ECT/TOR/P) and a LK-S Kyoto Liver/Kidney phantom were used. The NEMA IQ phantom was used to calibrate the camera and to produce CFs for the different spheres volumes and for varying sphere-to-background activity ratios. The spheres were filled with a uniform activity concentration of 177Lu, while the background was first filled with cold water and activity was added between each SPECT scan. SPECT imaging was performed for 30-s, 20-s, and 10-s exposure per view. The calculated CFs were expressed as function of the sphere volume and SBVR. The obtained CFs were validated for an additional NEMA IQ acquisition with different activities in spheres and background and for the Torso and Liver/Kidney phantoms with inserted NEMA IQ spheres. The quantification accuracy was compared with the conventional method not taking SBVR into consideration. RESULTS: The relative errors in quantification using the NEMA IQ phantom with the new calibration method were 0.16%, 5.77%, 9.34% for the large, medium and small sphere, respectively, for a time per view of 30-s. The conventional calibration method gave errors of 3.65%, 6.65%, 30.28% for 30-s. The LK-S Kyoto Liver/Kidney Phantom resulted in quantification errors of 3.40%, 2.14%, 11.18% for the large, medium and small spheres, respectively, for 30-s; compared to 11.31%, 17.54%, 14.43% for 30-s, respectively, for the conventional method. Similar results were obtained for shorter acquisitions times with 20-s and 10-s time per view. CONCLUSION: These results suggest that SBVR allows to improve quantification accuracy. The shorter time-per-view acquisitions had similar relative differences compared to the full-time acquisition which allows shorter imaging times with 177Lu and improved patient comfort. The SBVR method is simple to set up and can be proposed for standardization.

8.
Q J Nucl Med Mol Imaging ; 67(1): 75-82, 2023 Mar.
Article in English | MEDLINE | ID: mdl-33686849

ABSTRACT

BACKGROUND: Omission errors in medical imaging can lead to missed diagnosis and harm to patients. The subject has been studied in conventional imaging, but no data is available for functional imaging in general and for PET/CT in particular. In this work, we evaluated the frequency and characteristics of perceptual omission errors in the PET component of oncologic PET/CT imaging, and we analyzed the hazardous scenarios prone to such modality-specific errors. METHODS: Perceptual omission errors were collected in one tertiary center PET/CT clinic during routine PET/CT reporting over a 26-month period. The omissions were detected either in reporting follow-up PET/CT studies of the same patient or during multidisciplinary meetings. RESULTS: Significant omission errors were found in 1.2% of the 2100 reports included in the study. The most common omissions were bone metastases and focal colon uptake. We identified six PET-specific causative factors contributing to the occurrence of omissions, and we propose solutions to minimize their influence. CONCLUSIONS: The data presented here can help to promote the awareness of interpreting physicians to body areas that require higher attention and to implement reading strategies for improving the accuracy of PET/CT interpretation.


Subject(s)
Bone Neoplasms , Positron Emission Tomography Computed Tomography , Humans , Positron Emission Tomography Computed Tomography/methods , Positron-Emission Tomography , Tomography, X-Ray Computed , Bone Neoplasms/secondary , Fluorodeoxyglucose F18
9.
Front Surg ; 9: 943760, 2022.
Article in English | MEDLINE | ID: mdl-35813044

ABSTRACT

Background: PET-CT using prostate-specific membrane antigen (PSMA)-targeting radiopharmaceuticals labeled with 68Ga or 18F has emerged as the most sensitive staging tool in prostate cancer (PC). Nonetheless, the occurrence of false positive (FP) findings presents a major concern of this approach. In this prospective study, we investigated the frequency and pattern of false-positive findings of [18F]PSMA-1007 PET/CT in patients after radical prostatectomy with undetectable serum PSA levels. Any discrete non-physiological accumulation of [18F]PSMA-1007 in this population is by definition FP. Methods: Seventeen men after radical prostatectomy, whose serum PSA levels were <0.05 ng/mL at 2-24 months after surgery were prospectively recruited. PET/CT was acquired at both 1 and 2 h after injection of [18F]PSMA-1007. Findings: Three studies (18%) were interpreted as completely normal. Thirty-five foci of "non-physiological" uptake were observed in the remaining 14 (82%) patients, including a single skeletal focus in four patients, multiple skeletal foci in five patients and soft tissue uptake in eight, including in a desmoid tumor and in pelvic lymphocele. The SUVmax of all lesions was in the range of 1-7, except for the desmoid tumor which measured 12.7. All foci were visible in both the 1- and the 2 h studies, presenting a minor (<10%), statistically insignificant increase of SUVmax during this time-interval. Interpretation: FP [18F]PSMA-1007-avid foci are found in about 80% of patients with undetectable serum PSA levels. Thus, focal uptake of [18F]PSMA-1007 outside its physiological distribution is not a categorical sign of metastasis and can arise from non-specific uptake of the ligand. The interpretation of [18F]PSMA-1007 PET/CT studies should always consider the clinical context, and lesions with SUVmax < 7 are suspicious for FP.

10.
Laryngoscope ; 132(11): 2164-2168, 2022 11.
Article in English | MEDLINE | ID: mdl-35199860

ABSTRACT

OBJECTIVE: Sentinel node (SN) biopsy following lymphoscintography is recommended for high-risk cutaneous malignancies. Herein, we investigate different lymphoscintography phases, focusing on the importance of the late static phase and the resultant discovery of distal echelon solitary positive sentinel nodes that would otherwise have been overlooked. METHODS: In this retrospective cohort study, conducted in a tertiary referral medical center, we assessed SN localization and time from tracer injection to SN identification on lymphoscintigraphy. Findings on scan were compared with SN found in the surgical field, and with the final pathological investigation. RESULTS: Seventy-three patients, undergoing SN biopsy for head and neck skin malignancies, were investigated. Most patients were male (n = 50). The average age was 65.7 (±15.7) years and the average follow-up time was 29.1 (±22.4) months. Overall, 101 SNs were histologically investigated, demonstrating 7 positive SN. Eleven patients (15%) benefited from the late lymphoscintigraphy phase. In four studies, an SN was identified only in the late static phase, one of which was positive for the disease. In seven patients, SN was identified in the early phase with additional, different, SN on the late phase, one of which was positive for the disease. Comparing the yield (positive SNs) of early versus late phases, demonstrated the same importance (p = 0.275). CONCLUSIONS: The late lymphoscintigraphy phase has a crucial role in high-risk HN cutaneous cancer. LEVEL OF EVIDENCE: 3 Laryngoscope, 132:2164-2168, 2022.


Subject(s)
Head and Neck Neoplasms , Lymphadenopathy , Melanoma , Sentinel Lymph Node , Skin Neoplasms , Aged , Female , Head and Neck Neoplasms/surgery , Humans , Lymph Nodes/pathology , Lymphoscintigraphy , Male , Melanoma/pathology , Retrospective Studies , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node/pathology , Sentinel Lymph Node Biopsy , Skin Neoplasms/pathology
13.
J Nucl Med ; 63(3): 453-460, 2022 03.
Article in English | MEDLINE | ID: mdl-34301777

ABSTRACT

Vaccination against coronavirus 2019 (COVID-19) has created new challenges. Lymphadenopathy with increased uptake in patients undergoing PET/CT may mislead to unnecessary further evaluation. We have analyzed routinely performed PET/CT studies after Pfizer-BioNTech vaccination to familiarize ourselves with the PET/CT appearance of various PET tracers and to prevent the consequences of misinterpretation. Methods: We analyzed 1,018 PET/CT studies performed between January 1, 2021, and February 15, 2021. Information about the dates and sites of vaccination was collected. Visual and semiquantitative analysis of axillary-neck lymphadenopathy and arm uptake was correlated with immunization data. Results: Increased uptake in axillary lymphadenopathy was observed unilaterally in 66% of vaccinated patients, in 55% of patients vaccinated once, and in 69% of those vaccinated twice. The intensity of uptake decreased over time. Fifty-four of 274 patients (20%) had simultaneous increased activity in the posterior arm and ipsilateral axillary lymphadenopathy (double sign [DS]). The sensitivity, specificity, positive predictive value, and negative predictive value were 55.4%, 83.6%, 86.7%, 49.2%, respectively, for axillary lymphadenopathy and 38.6%, 100%, 100%, and 66.1%, respectively, for DS. No DS was observed later than 10 and 21 d after the first and the second vaccinations, respectively. None of the nonvaccinated patients had arm uptake or DS. Conclusion: Vaccination against COVID-19 frequently causes nonspecific axillary lymphadenopathy with increased PET tracer activity. In one fifth of our study population, this lymphadenopathy was associated with increased uptake at the vaccination site, DS. DS was 100% specific, with a 100% positive predictive value for postvaccination lymphadenopathy, hence enabling avoidance of misinterpretation of PET/CT studies and further unnecessary evaluation.


Subject(s)
BNT162 Vaccine/immunology , COVID-19/prevention & control , Positron Emission Tomography Computed Tomography/methods , SARS-CoV-2/immunology , Vaccination , BNT162 Vaccine/adverse effects , Female , Fluorodeoxyglucose F18 , Humans , Lymph Nodes/diagnostic imaging , Lymphadenopathy/etiology , Male , Retrospective Studies
14.
J Nucl Med ; 63(2): 218-225, 2022 02.
Article in English | MEDLINE | ID: mdl-34049983

ABSTRACT

The purpose of this study was to assess the efficacy and safety of 177Lu-DOTATATE in patients with somatostatin receptor (SSR)-positive lung neuroendocrine tumors (NETs). Methods: This is a retrospective review of the outcome of patients with typical carcinoid (TC) and atypical carcinoid (AC), treated with 177Lu-DOTATATE at 2 ENETS Centers of Excellence. Morphologic imaging (RECIST 1.1) and 68Ga-DOTATATE PET/CT responses were assessed at 3 mo after completion of 177Lu-DOTATATE. Concordance between 2 response assessment methods was evaluated by κ statistics. Progression-free survival (PFS) and overall survival (OS) were estimated by Kaplan-Meier analysis and compared by Log-rank test. Treatment-related adverse events (AEs) were graded based on Common Terminology Criteria for Adverse Events, version 5. Results: Of 48 patients (median age, 63 y; 13 women), 43 (90%) had AC and 5 (10%) TC. Almost all patients (47, 98%) were treated due to progression. Most patients (40, 83%) received somatostatin analogs, and 10 patients (20%) had prior everolimus, chemotherapy, or both. All patients had high SSR expression (≥ modified Krenning score 3) on pretreatment 68Ga-DOTATATE PET/CT. Patients received a median 4 (range, 1-4) cycles of 177Lu-DOTATATE (33% with concurrent radiosensitizing chemotherapy) to a median cumulative activity of 27 GBq (range, 6-43GBq). At a median follow-up of 42 mo, the median PFS and OS were 23 mo (95% CI, 18-28 mo) and 59 mo (95% CI, 50-not reached [NR]), respectively. Of 40 patients with RECIST-measurable disease and 39 patients with available 68Ga-DOTATATE PET/CT, response categories were partial response, 20% (95% CI, 10%-35%) and 44% (95% CI, 30%-59%); stable disease, 68% (95% CI, 52%-80%) and 44% (95% CI, 30%-59%); and progressive disease, 12% (95% CI, 5%-27%) by both, respectively. There was a moderate concordance between response categories by RECIST and 68Ga-DOTATATE PET/CT, weighted κ of 0.51 (95% CI, 0.21-0.68). Of patients with stable disease by RECIST, those with partial response on 68Ga-DOTATATE PET/CT had a longer OS than those with no response, NR versus 52 mo (95% CI, 28-64), hazard ratio 0.2 (95% CI, 0.1-0.6), P < 0.001. Most grade 3/4 AEs were reversible and the most common was lymphopenia (14%) with no incidence of myelodysplasia or leukemia. Conclusion: In patients with advanced progressive lung NET and satisfactory SSR expression, 177Lu-DOTATATE is effective and safe with a high disease control rate and encouraging PFS and OS.


Subject(s)
Lung Neoplasms/radiotherapy , Neuroendocrine Tumors/radiotherapy , Octreotide/analogs & derivatives , Organometallic Compounds/therapeutic use , Radiopharmaceuticals/therapeutic use , Adult , Aged , Aged, 80 and over , Female , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/mortality , Male , Middle Aged , Neuroendocrine Tumors/diagnostic imaging , Neuroendocrine Tumors/mortality , Octreotide/adverse effects , Octreotide/therapeutic use , Organometallic Compounds/adverse effects , Positron Emission Tomography Computed Tomography , Retrospective Studies
15.
EJNMMI Res ; 11(1): 86, 2021 Sep 06.
Article in English | MEDLINE | ID: mdl-34487268

ABSTRACT

BACKGROUND: 99mTc-labelled bisphosphonates are used for imaging assessment of patients with transthyretin cardiac amyloidosis (ATTR). Present study evaluates whether quantitative SPECT/CT measurement of absolute myocardial 99mTc-labelled 3,3-diphosphono-1,2-propanodicarboxylic acid (Tc-DPD) uptake can diagnose patients with suspected ATTR. METHODS: Twenty-eight patients (25 male, age 80.03 ± 6.99 years) with suspected ATTR referred for Tc-DPD imaging had planar and SPECT/CT imaging of the chest. Three operators independently obtained Tc-DPD myocardial SUVmax and SUVmean above threshold (SMaT) (20, 40 and 60% of SUVmax), using a semi-automated threshold segmentation method. Results were compared to visual grading (0-3) of cardiac uptake. RESULTS: Twenty-two patients (78%) had cardiac uptake (2 grade 1, 15 grade 2, 5 grade 3). SUVmax and SMaT segmentation thresholds enabled separating grades 2/3 from 0/1 with excellent inter- and intra-reader correlation. Cut-off values 6.0, 2.5, 3 and 4 for SUVmax, SMaT20,40,60, respectively, separated between grades 2/3 and 0 /1 with PPV and NPV of 100%. SMaT20,40,60(cardiac)/SUVmean (liver) and SMaT20,40,60(cardiac)/SUVmean(liver/lung) separated grades 2 and 3. CONCLUSION: Quantitative SPECT/CT parameters of cardiac Tc-DPD uptake are robust, enabling separation of patients with grades 2 and 3 cardiac uptake from grades 0 and 1. Larger patient cohorts will determine the incremental value of SPECT/CT quantification for ATTR management.

16.
Brain Commun ; 3(3): fcab197, 2021.
Article in English | MEDLINE | ID: mdl-34514401

ABSTRACT

Biallelic pathogenic variants in PRKN (PARK2), encoding the E3 ubiquitin ligase parkin, lead to early-onset Parkinson's disease. Structural variants, including duplications or deletions, are common in PRKN due to their location within the fragile site FRA6E. These variants are readily detectable by copy number variation analysis. We studied four siblings with levodopa-responsive dystonia by exome sequencing followed by genome sequencing. Affected individuals developed juvenile levodopa-responsive dystonia with subsequent appearance of parkinsonism and motor fluctuations that improved by subthalamic stimulation. Exome sequencing and copy number variation analysis were not diagnostic, yet revealed a shared homozygous block including PRKN. Genome sequencing revealed an inversion within PRKN, with intronic breakpoints flanking exon 5. Breakpoint junction analysis implicated non-homologous end joining and possibly replicative mechanisms as the repair pathways involved. Analysis of cDNA indicated skipping of exon 5 (84 bp) that was replaced by 93 bp of retained intronic sequence, preserving the reading frame yet altering a significant number of residues. Balanced copy number inversions in PRKN are associated with a severe phenotype. Such structural variants, undetected by exome analysis and by copy number variation analysis, should be considered in the relevant clinical setting. These findings raise the possibility that PRKN structural variants are more common than currently estimated.

17.
EJNMMI Phys ; 8(1): 63, 2021 Aug 26.
Article in English | MEDLINE | ID: mdl-34436698

ABSTRACT

BACKGROUND: Following each cycle of peptide receptor radionuclide therapy (PRRT), absorbed doses by tumors and normal organs are typically calculated from three quantitative single-photon emission computed tomography (SPECT)/computed tomography (CT) studies acquired at t1 = 24 h, t2 = 96 h, t3 = 168 h after the first cycle of treatment and from a single study at t1 after the subsequent cycles. In the present study, we have assessed the feasibility of a single SPECT/CT study after each PRRT cycle using a trained multiple linear regression (MLR) model for absorbed dose calculation and have evaluated its impact on patient management. Quantitative [177Lu]-DOTA-TATE SPECT/CT data after PRRT of seventy-two consecutive metastatic neuroendocrine tumors patients were retrospectively evaluated. A set of 40 consecutive studies was used to train the MLR model. The two independent variables of the model included the time of imaging after administration of the treatment and the radiopharmaceutical activity concentration in a given  organ/tumor. The dependent variable was the dose absorbed by the organ/tumor obtained with the standard protocol. For bone marrow dosimetry, the independent variables included the time of imaging, and the blood and remainder of the body activity concentration. The model was evaluated in 32 consecutive patients. Absorbed doses were assessed for kidneys, bone marrow, liver, spleen and tumor sites. RESULTS: There was no difference in management decisions, whether PRRT can be safely continued or not because unsafe absorbed dose to risk organs between the standard and the MLR model-based protocol using a single SPECT/CT study performed at t3 = 168 h after the first cycle and at t1 = 24 h after the subsequent cycles. Cumulative absorbed doses were obtained with mean relative differences of - 0.5% ± 5.4%, 1.6% ± 15.1%, - 6.2% ± 7.3%, - 5.5% ± 5.8% and 2.9% ± 12.7% for kidneys, bone marrow, liver, spleen and tumors, respectively (Pearson's r correlation coefficient 0.99, 0.91, 0.99, 0.99 and 0.97, respectively). CONCLUSION: Dosimetry calculations using a MLR model with a single SPECT/CT study are in good agreement with the standard protocol, while avoiding the use of dosimetry software and enabling improved patient comfort and reduced scanner and staff time.

18.
Harefuah ; 160(7): 419-424, 2021 07.
Article in Hebrew | MEDLINE | ID: mdl-34263567

ABSTRACT

AIMS: The aim of this study was to evaluate the predictive power of the absorbed dose to kidneys after the first course of treatment with [177Lu]-DOTA-TATE on the cumulative kidney absorbed dose after 3 or 4 cycles of treatment. BACKGROUND: Peptide receptor radionuclide therapy (PRRT) with [177Lu]-DOTA-TATE is an effective treatment for somatostatin receptor positive neuroendocrine tumors (NETs). Post-treatment scans (PTS) are required after each cycle of treatment for personalized radiation dosimetry in order to calculate the dose to organs and tumors and to ensure a cumulative absorbed dose to kidneys under a safety threshold of 25 Gy. METHODS: A total of 187 patients who completed treatment and underwent PTS for dosimetry calculation were included in this retrospective study. The correlation between the cumulative absorbed dose to the kidneys after completion of treatment and the absorbed dose after the first cycle(s) was studied. Multilinear regression analysis was performed to predict the cumulative absorbed dose by the kidneys in the subsequent cycles. An algorithm for the follow-up of the kidney absorbed dose is proposed. RESULTS: When the absorbed dose to kidneys after the first cycle of treatment is below 5.6 Gy, four cycles of treatment can be safely administered with a cumulative dose less than 25 Gy (p < 0.1). For the remaining patients, the cumulative dose absorbed after 3 or 4 cycles of treatment can be predicted after the second cycle of treatment. This protocol enabled early decisions on the number of treatment cycles and reduced the number of post-treatment SPECT/CT studies for dosimetry in 34% of patients, as well as hospitalization time for 56% of the treatment cycles. CONCLUSIONS: Assessment of the kidney absorbed dose after PRRT can be simplified with the algorithm presented in this study. This approach enabled early decisions on the number of therapy cycles in 75% of patients. DISCUSSION: The validity of these results is limited to the protocol of dosimetry calculation used in our institution. Implementation in other centers may require standardization of the acquisition parameters and the dosimetry protocol.


Subject(s)
Neuroendocrine Tumors , Radiation Exposure , Humans , Neuroendocrine Tumors/radiotherapy , Radioisotopes , Radiometry , Retrospective Studies
19.
Surg Oncol ; 38: 101567, 2021 Sep.
Article in English | MEDLINE | ID: mdl-33866190

ABSTRACT

INTRODUCTION: Breast cancer outcome is dependent on disease stage. The aim of the study was to assess the role of PET/CT in the evaluation of axillary lymph node and distant metastases in women with newly diagnosed primary breast cancer. MATERIALS AND METHODS: We assessed, among patients with newly diagnosed primary breast cancer, associations of [18F] fluorodeoxyglucose (FDG) uptake (maximum standardized uptake value [SUVmax]) with clinical variables of the primary tumor, including regional nodal status and the presence of distant metastases. RESULTS: Of 324 patients, 265 (81.8%) had focal uptake of FDG that corresponded with the cancerous lesion, and 21 (6.5%) had no FDG-avid findings. The remaining 38 patients had diffuse or nonspecific uptake of FDG. Among patients with a focal uptake of FDG (n = 265), the mean tumor size was 2.6 ± 1.9 (range 0.5-13.5), and the mean SUVmax was 5.3 ± 4.9 (range 1.2-25.0). In 83 patients (25.6%), PET/CT demonstrated additional suspected foci in the same breast. FDG-avid lymphadenopathy was observed in 156 patients (48.1%). Further assessment of lymph node involvement was available for 55/156 patients (axillary lymph node dissection [n = 21]; core needle biopsy [n = 34]) and confirmed axillary lymph node metastases in 47 (85.5%)). Thirteen patients (4.0%) had FDG-avid supraclavicular lymph nodes and six (1.9%) had FDG-avid internal mammary lymph nodes. Distant FDG-avid lesions were detected in 33 patients (10.2%). CONCLUSION: PET/CT is a useful diagnostic tool for staging breast cancer patients, but its use should be limited to specific clinical situations; further evaluation is needed.


Subject(s)
Breast Neoplasms/pathology , Fluorodeoxyglucose F18/metabolism , Lymph Nodes/pathology , Lymphatic Metastasis/pathology , Neoplasm Metastasis/diagnosis , Positron Emission Tomography Computed Tomography/methods , Radiopharmaceuticals/metabolism , Adult , Aged , Aged, 80 and over , Axilla , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/metabolism , Breast Neoplasms/surgery , Female , Follow-Up Studies , Humans , Lymph Nodes/diagnostic imaging , Lymphatic Metastasis/diagnostic imaging , Middle Aged , Neoplasm Metastasis/diagnostic imaging , Neoplasm Staging , Retrospective Studies
20.
EJNMMI Phys ; 8(1): 13, 2021 Feb 12.
Article in English | MEDLINE | ID: mdl-33580359

ABSTRACT

BACKGROUND: Image quality and quantitative accuracy of positron emission tomography (PET) depend on several factors such as uptake time, scanner characteristics and image reconstruction methods. Ordered subset expectation maximization (OSEM) is considered the gold standard for image reconstruction. Penalized-likelihood estimation (PL) algorithms have been recently developed for PET reconstruction to improve quantitation accuracy while maintaining or even improving image quality. In PL algorithms, a regularization parameter ß controls the penalization of relative differences between neighboring pixels and determines image characteristics. In the present study, we aim to compare the performance of Q.Clear (PL algorithm, GE Healthcare) and OSEM (3 iterations, 8 subsets, 6-mm post-processing filter) for 68Ga-DOTATATE (68Ga-DOTA) PET studies, both visually and quantitatively. Thirty consecutive whole-body 68Ga-DOTA studies were included. The data were acquired in list mode and were reconstructed using 3D OSEM and Q.Clear with various values of ß and various acquisition times per bed position (bp), thus generating images with reduced injected dose (1.5 min/bp: ß = 300-1100; 1.0 min/bp: ß = 600-1400 and 0.5 min/bp: ß = 800-2200). An additional analysis adding ß values up to 1500, 1700 and 3000 for 1.5, 1.0 and 0.5 min/bp, respectively, was performed for a random sample of 8 studies. Evaluation was performed using a phantom and clinical data. Two experienced nuclear medicine physicians blinded to the variables assessed the image quality visually. RESULTS: Clinical images reconstructed with Q.Clear, set at 1.5, 1.0 and 0.5 min/bp using ß = 1100, 1300 and 3000, respectively, resulted in images with noise equivalence to 3D OSEM (1.5 min/bp) with a mean increase in SUVmax of 14%, 13% and 4%, an increase in SNR of 30%, 24% and 10%, and an increase in SBR of 13%, 13% and 2%. Visual assessment yielded similar results for ß values of 1100-1400 and 1300-1600 for 1.5 and 1.0 min/bp, respectively, although for 0.5 min/bp there was no significant improvement compared to OSEM. CONCLUSION: 68Ga-DOTA reconstructions with Q.Clear, 1.5 and 1.0 min/bp, resulted in increased tumor SUVmax and in improved SNR and SBR at a similar level of noise compared to 3D OSEM. Q.Clear with ß = 1300-1600 enables one-third reduction of acquisition time or injected dose, with similar image quality compared to 3D OSEM.

SELECTION OF CITATIONS
SEARCH DETAIL
...