Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
2.
JACC Cardiovasc Interv ; 16(15): 1889-1898, 2023 08 14.
Article in English | MEDLINE | ID: mdl-37587597

ABSTRACT

BACKGROUND: Left atrial appendage occlusion (LAAO) procedures are widely guided by standard transesophageal echocardiography (TEE) probes, requiring general anesthesia in most patients. The use of miniaturized TEE probes allows for LAAO guidance under local anesthesia and offers an attractive imaging alternative to standard TEE probes. OBJECTIVES: The aim of this study was to assess the safety and efficacy of miniaturized TEE probes for procedural guidance of LAAO. METHODS: Multicenter retrospective observational study of LAAO procedures performed under miniaturized TEE guidance and conscious sedation. The primary efficacy endpoint was technical success. The secondary efficacy endpoint was procedural success (technical success without major periprocedural complications). The safety outcome was a composite of major periprocedural complications. RESULTS: A total of 546 consecutive LAAO procedures were performed in 5 European centers. Technical success was achieved in 534 (98.0%) patients. Sixteen major periprocedural complications occurred in 15 (2.9%) patients, yielding a procedural success rate of 97.0%. Conversion to general anesthesia was required in 4 (0.7%) patients. Short-term imaging follow-up was available in 422 patients with an incidence of major (>5 mm) TEE-detected residual leaks of 0.7%, complete LAA occlusion of 82.2% on cardiac computed tomography, and device-related thrombus of 5%. As compared with procedural 2-dimensional imaging for device sizing, preprocedural assessment by 3-dimensional imaging resulted in improved technical success (100% vs 95.0%; P < 0.001). CONCLUSIONS: LAAO under conscious sedation and miniaturized TEE guidance is safe and feasible with a high rate of technical success and a low rate of periprocedural complications.


Subject(s)
Atrial Appendage , Echocardiography, Transesophageal , Humans , Conscious Sedation/adverse effects , Atrial Appendage/diagnostic imaging , Treatment Outcome , Anesthesia, General
4.
Catheter Cardiovasc Interv ; 97(7): E1025-E1032, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33580751

ABSTRACT

OBJECTIVES: To describe imaging assessment, procedural and follow-up outcome of patients undergoing left atrial appendage (LAA) occlusion (LAAO) using a "sandwich" technique. BACKGROUND: The presence of a LAA with chicken wing morphology constitutes a challenge that sometimes requires specific occlusion strategies like the "sandwich" technique. However, procedural and follow-up data focusing on this implanting strategy is scarce. METHODS: This multicenter study collected individual data from eight centers between 2012 and 2019. Consecutive patients with chicken-wing LAAs defined as an early (<20 mm from the ostium) and severe bend (>90°) who underwent LAAO with Amplatzer devices and using the "sandwich" technique were included in the analysis. RESULTS: Overall, 190 subjects were enrolled in the study. Procedures were done with the Amulet device (85%) and the Amplatzer Cardiac Plug (15%). Successful implantation was achieved in 99.5% with ≤1 partial recapture in 80% of cases. Single (46.2%) and dual antiplatelet therapy (39.4%) were the most used antithrombotic therapies after LAAO. In-hospital major adverse events rate was 1.5% with no deaths. One patient (0.5%) had cardiac tamponade requiring percutaneous drainage. With a mean follow-up of 19.6 ± 14.8 months, the mortality and stroke rates were 7.7%/year and 2.5%/year, respectively. Follow-up transesophageal echocardiography (TEE) at 2-3 months showed device-related thrombosis in 2.8% and peri-device leak ≥3 mm in 1.2% of patients. CONCLUSIONS: In a large series of patients with chicken wing LAA anatomies undergoing LAAO, the use of the "sandwich" technique was feasible and safe. Preprocedural imaging was a key-factor to determine specific measurements.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Echocardiography, Transesophageal , Humans , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...