Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 67
Filter
3.
Radiology ; 294(1): 168-185, 2020 01.
Article in English | MEDLINE | ID: mdl-31687921

ABSTRACT

The Ovarian-Adnexal Reporting and Data System (O-RADS) US risk stratification and management system is designed to provide consistent interpretations, to decrease or eliminate ambiguity in US reports resulting in a higher probability of accuracy in assigning risk of malignancy to ovarian and other adnexal masses, and to provide a management recommendation for each risk category. It was developed by an international multidisciplinary committee sponsored by the American College of Radiology and applies the standardized reporting tool for US based on the 2018 published lexicon of the O-RADS US working group. For risk stratification, the O-RADS US system recommends six categories (O-RADS 0-5), incorporating the range of normal to high risk of malignancy. This unique system represents a collaboration between the pattern-based approach commonly used in North America and the widely used, European-based, algorithmic-style International Ovarian Tumor Analysis (IOTA) Assessment of Different Neoplasias in the Adnexa model system, a risk prediction model that has undergone successful prospective and external validation. The pattern approach relies on a subgroup of the most predictive descriptors in the lexicon based on a retrospective review of evidence prospectively obtained in the IOTA phase 1-3 prospective studies and other supporting studies that assist in differentiating management schemes in a variety of almost certainly benign lesions. With O-RADS US working group consensus, guidelines for management in the different risk categories are proposed. Both systems have been stratified to reach the same risk categories and management strategies regardless of which is initially used. At this time, O-RADS US is the only lexicon and classification system that encompasses all risk categories with their associated management schemes.


Subject(s)
Ovarian Neoplasms/diagnostic imaging , Radiology Information Systems , Ultrasonography/methods , Adnexal Diseases , Female , Humans , Prospective Studies , Retrospective Studies , Risk Assessment , Societies, Medical , United States
4.
Obstet Gynecol Clin North Am ; 46(4): 755-781, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31677753

ABSTRACT

3D ultrasound imaging of the female pelvis is one of the most important recent advances in diagnostic imaging. Volume acquisitions can provide a large number of images of the pelvic organs simultaneously and in any plane or orientation desired. The coronal plane of the uterus is only visible when reconstructed from a volume and is key to imaging the uterus for indications such as uterine anomalies, IUD positioning, locations of fibroids and polyps, or early pregnancies. 3D ultrasonography has huge potential for evaluating infertile patients, performing difficult procedures under guidance, and studying patients with abnormal uterine bleeding, hydrosalpinges, and cancer.


Subject(s)
Genital Diseases, Female/diagnostic imaging , Genitalia, Female/diagnostic imaging , Pelvis/diagnostic imaging , Ultrasonography/methods , Female , Genital Diseases, Female/etiology , Humans , Imaging, Three-Dimensional
13.
Radiology ; 293(2): 359-371, 2019 11.
Article in English | MEDLINE | ID: mdl-31549945

ABSTRACT

This multidisciplinary consensus update aligns prior Society of Radiologists in Ultrasound (SRU) guidelines on simple adnexal cysts with recent large studies showing exceptionally low risk of cancer associated with simple adnexal cysts. Most small simple cysts do not require follow-up. For larger simple cysts or less well-characterized cysts, follow-up or second opinion US help to ensure that solid elements are not missed and are also useful for assessing growth of benign tumors. In postmenopausal women, reporting of simple cysts greater than 1 cm should be done to document their presence in the medical record, but such findings are common and follow-up is recommended only for simple cysts greater than 3-5 cm, with the higher 5-cm threshold reserved for simple cysts with excellent imaging characterization and documentation. For simple cysts in premenopausal women, these thresholds are 3 cm for reporting and greater than 5-7 cm for follow-up imaging. If a cyst is at least 10%-15% smaller at any time, then further follow-up is unnecessary. Stable simple cysts at initial follow-up may benefit from a follow-up at 2 years due to measurement variability that could mask growth. Simple cysts that grow are likely cystadenomas. If a previously suspected simple cyst demonstrates papillary projections or solid areas at follow-up, then the cyst should be described by using standardized terminology. These updated SRU consensus recommendations apply to asymptomatic patients and to those whose symptoms are not clearly attributable to the cyst. These recommendations can reassure physicians and patients regarding the benign nature of simple adnexal cysts after a diagnostic-quality US examination that allows for confident diagnosis of a simple cyst. Patients will benefit from less costly follow-up, less anxiety related to these simple cysts, and less surgery for benign lesions.


Subject(s)
Adnexal Diseases/diagnostic imaging , Cysts/diagnostic imaging , Precancerous Conditions/diagnostic imaging , Ultrasonography/methods , Adnexal Diseases/pathology , Adult , Aged , Cysts/pathology , Diagnosis, Differential , Female , Humans , Middle Aged , Practice Guidelines as Topic , Precancerous Conditions/pathology
14.
J Ultrasound Med ; 38(10): 2673-2683, 2019 Oct.
Article in English | MEDLINE | ID: mdl-30801764

ABSTRACT

OBJECTIVES: To evaluate the intra- and inter-rater agreement for myometrial lesions using Morphologic Uterus Sonographic Assessment terminology. METHODS: Thirteen raters with high (n = 6) or medium experience (n = 7) assessed 30 3-dimensional ultrasound clips with (n = 20) and without (n = 10) benign myometrial lesions. Myometrial lesions were reported as poorly or well defined and then systematically evaluated for the presence of individual features. The clips were blindly assessed twice (at a 2-month interval). Intra- and inter-rater agreements were calculated with κ statistics. RESULTS: The reporting of poorly defined lesions reached moderate intra-rater agreement (κ = 0.49 [high experience] and 0.47 [medium experience]) and poor inter-rater agreement (κ = 0.39 [high experience] and 0.25 [medium experience]). The reporting of well-defined lesions reached good to very good intra-rater agreement (κ = 0.73 [high experience] and 0.82 [medium experience]) and good inter-rater agreement (κ = 0.75 [high experience] and 0.63 [medium experience]). Most individual features associated with ill-defined lesions reached moderate intra- and inter-rater agreement among highly experienced raters (κ = 0.41-0.60). The least reproducible features were myometrial cysts, hyperechoic islands, subendometrial lines and buds, and translesional flow (κ = 0.11-0.34). Most individual features associated with well-defined lesions reached moderate to good intra- and inter-rater agreement among all observers (κ = 0.41-0.80). The least reproducible features were a serosal contour, asymmetry, a hyperechoic rim, and fan-shaped shadows (κ = 0.00-0.35). CONCLUSIONS: The reporting of well-defined lesions showed excellent agreement, whereas the agreement for poorly defined lesions was low, even among highly experienced raters. The agreement on identifying individual features varied, especially for features associated with ill-defined lesions. Guidelines on minimum requirements for features associated with ill-defined lesions to be interpreted as poorly defined lesions may improve agreement.


Subject(s)
Myometrium/diagnostic imaging , Ultrasonography/methods , Uterine Neoplasms/diagnostic imaging , Adult , Female , Humans , Imaging, Three-Dimensional/methods , Middle Aged , Observer Variation , Pilot Projects , Prospective Studies , Reproducibility of Results
15.
J Am Coll Radiol ; 15(10): 1415-1429, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30149950

ABSTRACT

Ultrasound is the most commonly used imaging technique for the evaluation of ovarian and other adnexal lesions. The interpretation of sonographic findings is variable because of inconsistency in descriptor terminology used among reporting clinicians. The use of vague terms that are inconsistently applied can lead to significant differences in interpretation and subsequent management strategies. A committee was formed under the direction of the ACR initially to create a standardized lexicon for ovarian lesions with the goal of improving the quality and communication of imaging reports between ultrasound examiners and referring clinicians. The ultimate objective will be to apply the lexicon to a risk stratification classification for consistent follow-up and management in clinical practice. This white paper describes the consensus process in the creation of a standardized lexicon for ovarian and adnexal lesions and the resultant lexicon.


Subject(s)
Adnexal Diseases/diagnostic imaging , Radiology Information Systems/standards , Ultrasonography , Consensus , Data Systems , Diagnosis, Differential , Female , Humans , Image Interpretation, Computer-Assisted , Practice Guidelines as Topic , Risk Assessment , Societies, Medical , United States
16.
Am J Obstet Gynecol ; 218(1): 29-67, 2018 01.
Article in English | MEDLINE | ID: mdl-29306447

ABSTRACT

Ultrasound imaging has become integral to the practice of obstetrics and gynecology. With increasing educational demands and limited hours in residency programs, dedicated time for training and achieving competency in ultrasound has diminished substantially. The American Institute of Ultrasound in Medicine assembled a multisociety task force to develop a consensus-based, standardized curriculum and competency assessment tools for obstetric and gynecologic ultrasound training in residency programs. The curriculum and competency assessment tools were developed based on existing national and international guidelines for the performance of obstetric and gynecologic ultrasound examinations and thus are intended to represent the minimum requirement for such training. By expert consensus, the curriculum was developed for each year of training, criteria for each competency assessment image were generated, the pass score was established at, or close to, 75% for each, and obtaining a set of 5 ultrasound images with pass score in each was deemed necessary for attaining each competency. Given the current lack of substantial data on competency assessment in ultrasound training, the task force expects that the criteria set forth in this document will evolve with time. The task force also encourages use of ultrasound simulation in residency training and expects that simulation will play a significant part in the curriculum and the competency assessment process. Incorporating this training curriculum and the competency assessment tools may promote consistency in training and competency assessment, thus enhancing the performance and diagnostic accuracy of ultrasound examination in obstetrics and gynecology.


Subject(s)
Clinical Competence/standards , Curriculum , Internship and Residency , Obstetrics/education , Quality Assurance, Health Care , Ultrasonography, Prenatal/standards , Accreditation , Female , Humans , Pregnancy , United States
17.
J Ultrasound Med ; 37(1): 7-18, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29297609

ABSTRACT

The Beyond Ultrasound First Forum was conceived to increase awareness that the quality of obstetric and gynecologic ultrasound can be improved, and is inconsistent throughout the country, likely due to multiple factors, including the lack of a standardized curriculum and competency assessment in ultrasound teaching. The forum brought together representatives from many professional associations; the imaging community including radiology, obstetrics and gynecology, and emergency medicine among others; in addition to government agencies, insurers, industry, and others with common interest in obstetric and gynecologic ultrasound. This group worked together in focus sessions aimed at developing solutions on how to standardize and improve ultrasound training at the resident level and beyond. A new curriculum and competency assessment program for teaching residents (obstetrics and gynecology, radiology, and any other specialty doing obstetrics and gynecology ultrasound) was presented, and performance measures of ultrasound quality in clinical practice were discussed. The aim of this forum was to increase and unify the quality of ultrasound examinations in obstetrics and gynecology with the ultimate goal of improving patient safety and quality of clinical care. This report describes the proceedings of this conference including possible approaches to resident teaching and means to improve the inconsistent quality of ultrasound examinations performed today.


Subject(s)
Clinical Competence/standards , Gynecology/education , Obstetrics/education , Quality Improvement , Ultrasonics/education , Ultrasonography, Prenatal/standards , Curriculum/standards , Female , Humans , Pregnancy , United States
18.
J Ultrasound Med ; 37(1): 19-50, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29297610

ABSTRACT

Ultrasound imaging has become integral to the practice of obstetrics and gynecology. With increasing educational demands and limited hours in residency programs, dedicated time for training and achieving competency in ultrasound has diminished substantially. The American Institute of Ultrasound in Medicine assembled a multisociety task force to develop a consensus-based, standardized curriculum and competency assessment tools for obstetric and gynecologic ultrasound training in residency programs. The curriculum and competency assessment tools were developed based on existing national and international guidelines for the performance of obstetric and gynecologic ultrasound examinations and thus are intended to represent the minimum requirement for such training. By expert consensus, the curriculum was developed for each year of training, criteria for each competency assessment image were generated, the pass score was established at, or close to, 75% for each, and obtaining a set of 5 ultrasound images with pass score in each was deemed necessary for attaining each competency. Given the current lack of substantial data on competency assessment in ultrasound training, the task force expects that the criteria set forth in this document will evolve with time. The task force also encourages use of ultrasound simulation in residency training and expects that simulation will play a significant part in the curriculum and the competency assessment process. Incorporating this training curriculum and the competency assessment tools may promote consistency in training and competency assessment, thus enhancing the performance and diagnostic accuracy of ultrasound examination in obstetrics and gynecology.


Subject(s)
Clinical Competence/standards , Curriculum/standards , Internship and Residency/standards , Ultrasonics/education , Ultrasonography, Prenatal/standards , Female , Gynecology/education , Humans , Obstetrics/education , Pregnancy , Quality Improvement , United States
19.
Am J Obstet Gynecol ; 218(1): 19-28, 2018 01.
Article in English | MEDLINE | ID: mdl-28688814

ABSTRACT

The Beyond Ultrasound First Forum was conceived to increase awareness that the quality of obstetric and gynecologic ultrasound can be improved, and is inconsistent throughout the country, likely due to multiple factors, including the lack of a standardized curriculum and competency assessment in ultrasound teaching. The forum brought together representatives from many professional associations; the imaging community including radiology, obstetrics and gynecology, and emergency medicine among others; in addition to government agencies, insurers, industry, and others with common interest in obstetric and gynecologic ultrasound. This group worked together in focus sessions aimed at developing solutions on how to standardize and improve ultrasound training at the resident level and beyond. A new curriculum and competency assessment program for teaching residents (obstetrics and gynecology, radiology, and any other specialty doing obstetrics and gynecology ultrasound) was presented, and performance measures of ultrasound quality in clinical practice were discussed. The aim of this forum was to increase and unify the quality of ultrasound examinations in obstetrics and gynecology with the ultimate goal of improving patient safety and quality of clinical care. This report describes the proceedings of this conference including possible approaches to resident teaching and means to improve the inconsistent quality of ultrasound examinations performed today.


Subject(s)
Clinical Competence , Internship and Residency , Obstetrics/education , Quality Assurance, Health Care , Quality Improvement , Ultrasonography, Prenatal , Accreditation , Female , Humans , Pregnancy , United States
20.
J Clin Ultrasound ; 45(6): 313-318, 2017 Jul 08.
Article in English | MEDLINE | ID: mdl-28414865

ABSTRACT

This review summarizes the current evidence regarding the diagnostic accuracy of sonography (US) in women with deep infiltrating endometriosis (DIE). It is well known that transvaginal ultrasound (TVUS) can detect ovarian endometriomas with a high degree of sensitivity. In recent years, US has also been used to detect DIE. In the hands of an experienced sonologist, the sensitivity and specificity of TVUS in the detection of DIE is comparable to those of MRI. TVUS can eliminate the need for an MRI in the majority of patients and reduce the need for diagnostic laparoscopy, proving to be an important tool in preoperative planning. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:313-318, 2017.


Subject(s)
Endometriosis/diagnostic imaging , Ultrasonography, Interventional/methods , Female , Humans , Pelvis/diagnostic imaging , Reproducibility of Results , Sensitivity and Specificity , Vagina
SELECTION OF CITATIONS
SEARCH DETAIL
...