Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Acta Ophthalmol ; 94(1): e11-5, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26348502

ABSTRACT

PURPOSE: To compare the anti-adhesive effect of cefuroxime and moxifloxacin on the primary attachment phase of Staphylococcus epidermidis on hydrophobic acrylic intraocular lenses (IOLs). METHODS: Forty hydrophobic acrylic IOLs were used. Two groups of IOLs were soaked in a moxifloxacin (Mox-T1: 0.5 mg/0.1 ml) or a cefuroxime (Cef-T1: cefuroxime 1 mg/0.1 ml) solution before incubation in a S. epidermidis bacterial suspension. Two other groups were incubated in the bacterial suspension before antibiotics (Cef-T2 and Mox-T2) were added. The control group (Ctrl) consisted of IOLs incubated in the bacterial suspension. After incubation, IOLs were sonicated and vortexed. The resultant suspension was spread over a nutritive agar plate. Bacterial colonies were counted after 24 hr of incubation. RESULTS: Mean number of colony-forming units per IOL was Cef-T1: 184 × 10(3) (SE: 5.24; SD: 28.21), Cef-T2: 117 × 10(3) (SE: 5.74; SD: 30.37), Mox-T1: 1.27 × 10(3) (SE: 0.12; SD: 0.61), Mox-T2: 25 × 10(3) (SE:1.98; SD: 9.72) and Ctrl: 361 × 10(3) (SE: 26.9; SD: 107.6). The number of adhering bacteria did not vary whether cefuroxime was added before or after IOL incubation in the bacterial suspension (p = 0.132). Moxifloxacin was more effective in reducing the number of adhering bacteria when used before IOL incubation (p < 0.001). Overall for T1 and T2, moxifloxacin was more effective than cefuroxime in reducing bacterial adhesion on IOLs (p < 0.001). CONCLUSION: Moxifloxacin and cefuroxime significantly reduced S. epidermidis adhesion on hydrophobic acrylic IOLs. The anti-adhesive effect was superior with moxifloxacin.


Subject(s)
Anti-Bacterial Agents/pharmacology , Bacterial Adhesion/drug effects , Cefuroxime/pharmacology , Fluoroquinolones/pharmacology , Lenses, Intraocular/microbiology , Staphylococcus epidermidis/physiology , Acrylic Resins , Colony Count, Microbial , Hydrophobic and Hydrophilic Interactions , Moxifloxacin
2.
J Nucl Med ; 55(1): 15-22, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24263087

ABSTRACT

UNLABELLED: Our group has developed a new radiopharmaceutical, (123)I - N-(2-diethylaminoethyl)-2-iodobenzamide ((123)I-BZA2), a benzamide derivative able to bind to melanin pigment in melanoma cells. In a prospective and multicentric phase III clinical study, the value of (18)F-FDG PET/CT and (123)I-BZA2 scintigraphy was compared for melanoma staging. METHODS: Patients with a past history of cutaneous or ocular melanoma were included from 8 hospitals. (18)F-FDG imaging was performed according to a standard PET protocol. Whole-body, static planar, and SPECT/CT (if available) images were acquired 4 h after injection of a 2 MBq/kg dose of (123)I-BZA2. (18)F-FDG and (123)I-BZA2 sensitivity and specificity for the diagnosis of melanoma metastasis were calculated and compared on both a lesion basis and a patient basis. True-positive and true-negative lesion status was determined after 6 mo of clinical follow-up or according to lesion biopsies (if available). Melanin content in biopsies was evaluated with the standard Fontana-Masson silver method and was correlated with (123)I-BZA2 uptake. Based on statistical analysis, the number of inclusions was estimated at 186. RESULTS: In all, 87 patients were enrolled from 2008 to 2010. Of these, 45 (52%) had metastases. A total of 338 imaging abnormalities were analyzed; 86 lesions were considered metastases, and 20 of 25 lesion biopsies found melanoma metastases. In a patient-based analysis, the sensitivity of (18)F-FDG for diagnosis of melanoma metastases was higher than that of (123)I-BZA2, at 87% and 39%, respectively (P < 0.05). For specificity, (18)F-FDG and (123)I-BZA2 were not statistically different, at 78% and 94%, respectively. In a lesion-based analysis, the sensitivity of (18)F-FDG was statistically higher than that of (123)I-BZA2 (80% vs. 23%, P < 0.05). The specificity of (18)F-FDG was lower than that of (123)I-BZA2 (54% vs. 86%, P < 0.05). According to biopsy analysis, only 9 of 20 metastatic lesions (45%) were pigmented with high melanin content. (123)I-BZA2 imaging was positive for 6 of 8 melanin-positive lesions, fairly positive for 3 of 10 melanin-negative lesions, and negative for 7 of 10 melanin-negative lesions. The sensitivity and specificity of (123)I-BZA2 for the diagnosis of melanin-positive lesions were 75% and 70%, respectively. Because of a low (123)I-BZA2 sensitivity, this clinical trial was prematurely closed after 87 patients had been included. CONCLUSION: This study confirms the value of (18)F-FDG PET/CT for melanoma staging and strengthens the high accuracy of (123)I-BZA2 for diagnosis of melanin-positive metastatic melanoma. Moreover, benzamide derivatives radiolabeled with therapeutic radionuclide may offer a new strategy for the treatment of metastatic melanoma patients harboring melanin-positive metastases.


Subject(s)
Benzamides , Iodine Radioisotopes , Melanins/chemistry , Melanoma/diagnostic imaging , Melanoma/pathology , Radiopharmaceuticals , Aged , Biopsy , Female , Fluorodeoxyglucose F18 , Humans , Image Processing, Computer-Assisted , Male , Melanins/biosynthesis , Middle Aged , Multimodal Imaging , Neoplasm Metastasis , Neoplasm Staging , Positron-Emission Tomography , Prospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...