Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 19(4): e0302274, 2024.
Article in English | MEDLINE | ID: mdl-38662796

ABSTRACT

In recent years, immune checkpoint inhibitors have proved immense clinical progression in the treatment of certain cancers. The efficacy of immune checkpoint inhibitors is correlated with mismatch repair system deficiency and is exceptionally administered based exclusively on this biological mechanism independent of the cancer type. The promising effect of immune checkpoint inhibitors has left an increasing demand for analytical tools evaluating the mismatch repair status. The analysis of microsatellite instability (MSI), reflecting an indirect but objective manner the inactivation of the mismatch repair system, plays several roles in clinical practice and, therefore, its evaluation is of high relevance. Analysis of MSI by PCR followed by fragment analysis on capillary electrophoresis remains the gold standard method for detection of a deficient mismatch repair system and thereby treatment with immune checkpoint inhibitors. Novel technologies have been applied and concepts such as tumor mutation burden have been introduced. However, to date, most of these technologies require high costs or the need of matched non-tumor tissue as internal comparator. In this study, we present a novel, one-instrument, fast, and objective method for the detection of MSI (MicroSight® MSI 1-step HRM Analysis), which does not depend on the use of matched non-tumor tissue. The assay analyzes five well-described mononucleotide microsatellite sequences by real-time PCR followed by high-resolution melt and evaluates microsatellite length variations via PCR product melting profiles. The assay was evaluated using two different patient cohorts and evaluation included several DNA extraction methodologies, two different PCR platforms, and an inter-laboratory ring study. The MicroSight® MSI assay showed a high repeatability regardless of DNA extraction method and PCR platform, and a 100% agreement of the MSI status with PCR fragment analysis methods applied as clinical comparator.


Subject(s)
Microsatellite Instability , Humans , DNA Mismatch Repair/genetics , Real-Time Polymerase Chain Reaction/methods , Female , Male , Microsatellite Repeats/genetics
2.
Nat Commun ; 14(1): 5153, 2023 08 24.
Article in English | MEDLINE | ID: mdl-37620381

ABSTRACT

DNA methylation is important for gene expression and alterations in DNA methylation are involved in the development and progression of cancer and other major diseases. Analysis of DNA methylation patterns has until now been dependent on either a chemical or an enzymatic pre-treatment, which are both time consuming procedures and potentially biased due to incomplete treatment. We present a qPCR technology, EpiDirect®, that allows for direct PCR quantification of DNA methylations using untreated DNA. EpiDirect® is based on the ability of Intercalating Nucleic Acids (INA®) to differentiate between methylated and unmethylated cytosines in a special primer design. With this technology, we develop an assay to analyze the methylation status of a region of the MGMT promoter used in treatment selection and prognosis of glioblastoma patients. We compare the assay to two bisulfite-relying, methyl-specific PCR assays in a study involving 42 brain tumor FFPE samples, revealing high sensitivity, specificity, and the clinical utility of the method.


Subject(s)
Polymerase Chain Reaction , Polymerase Chain Reaction/instrumentation , Polymerase Chain Reaction/methods , DNA/metabolism , DNA Methylation , Temperature , Oligonucleotides/metabolism , CpG Islands
3.
Microbiol Spectr ; 10(5): e0142222, 2022 10 26.
Article in English | MEDLINE | ID: mdl-36129278

ABSTRACT

We examined the detection rate of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using reverse transcription-PCR (RT-PCR) of side-by-side saliva and oropharyngeal swab (OPS) samples from 639 symptomatic and asymptomatic subjects, of which 47 subjects were found to be positive for SARS-CoV-2 in the OPS or saliva sample or both. It was found that the detection rate (93.6% for both OPS and saliva) as well as the sensitivity and specificity were comparable between the two sampling methods in this cohort. The sensitivity was 0.932 (95% confidence interval [CI], 0.818 to 0.977) and the specificity was 0.995 (95% CI, 0.985 to 0.998), both for saliva when OPS sampling was used as the reference and for OPS when saliva was used as the reference. Furthermore, the Cohen's kappa value was 0.926 (95% CI, 0.868 to 0.985), indicating strong agreement between the two sampling methods. In addition, the viral RNA stability in pure saliva and saliva mixed with preservation buffers was examined following storage at room temperature and at 4°C. It was found that pure saliva kept the viral RNA stable for 9 days at both temperatures and that the type of preservation buffer can either enhance or reduce the stability of the RNA. We conclude that self-administered saliva sampling is an attractive alternative to oropharyngeal swabbing for SARS-CoV-2 detection, and it might be useful in large-scale testing. IMPORTANCE It is not inconceivable that we will witness recurring surges of COVID-19 before the pandemic finally recedes. It is therefore still relevant to look for feasible, simple, and flexible screening methods so that schools, workplaces, and communities in general can avoid lockdowns. In this work, we analyzed two different sampling methods: oropharyngeal swabs and saliva collection. Oropharyngeal swabs must be collected by trained health personnel at clinics, whereas self-assisted saliva collection can be performed at any given location. It was found that the two sampling methods were comparable. Saliva sampling is a simple method that allows easy mass testing using minimal resources from the existing health care system, and this method may therefore prove to be an effective tool for containing the COVID-19 pandemic.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Pandemics , COVID-19/diagnosis , COVID-19 Testing , Saliva , RNA, Viral , Communicable Disease Control , Specimen Handling/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...