Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 17(6): e0270888, 2022.
Article in English | MEDLINE | ID: mdl-35771855

ABSTRACT

Notification badges are an unexplored category of visual feedback to which we are continuously exposed. This study aims to deepen knowledge on the topic by measuring the behavioral effects of notification badges on a large sample of smartphone users. More precisely, the goal of the study is to observe if the presence of notification badges increases the frequency of clicks on apps. More than 1000 participants were involved in a remote between-subjects experiment, allocated into fifteen equinumerous groups of comparison. Each participant was presented with a smartphone screen displaying fifteen app icons and just one badge notification. Participants were asked to perform a remote user test called First Impression Click Test: a methodology that indicates where they would click first to accomplish a given task (i.e., Where would you click first on this screen?). Our results show a large increase in the number of clicks on apps with notification badges compared to those without notification badges and suggest the important ability of these small affordances to attract attention and stimulate action. Based on the evidence provided, our findings have practical implications for user experience design.


Subject(s)
Mobile Applications , Smartphone , Humans , Motivation
2.
PLoS One ; 14(11): e0225592, 2019.
Article in English | MEDLINE | ID: mdl-31756239

ABSTRACT

Remote photoplethysmography (rPPG) allows contactless monitoring of human cardiac activity through a video camera. In this study, we assessed the accuracy and precision for heart rate measurements of the only consumer product available on the market, namely the FacereaderTM rPPG by Noldus, with respect to a gold standard electrocardiograph. Twenty-four healthy participants were asked to sit in front of a computer screen and alternate two periods of rest with two stress tests (i.e. Go/No-Go task), while their heart rate was simultaneously acquired for 20 minutes using the ECG criterion measure and the FacereaderTM rPPG. Results show that the FacereaderTM rPPG tends to overestimate lower heart rates and underestimate higher heart rates compared to the ECG. The Facereader™ rPPG revealed a mean bias of 9.8 bpm, the 95% limits of agreement (LoA) ranged from almost -30 up to +50 bpm. These results suggest that whilst the rPPG FacereaderTM technology has potential for contactless heart rate monitoring, its predictions are inaccurate for higher heart rates, with unacceptable precision across the entire range, rendering its estimates unreliable for monitoring individuals.


Subject(s)
Heart Rate , Photoplethysmography/methods , Adult , Electrocardiography , Female , Humans , Male , Young Adult
3.
PLoS One ; 13(2): e0192691, 2018.
Article in English | MEDLINE | ID: mdl-29489850

ABSTRACT

Fitness trackers are devices or applications for monitoring and tracking fitness-related metrics such as distance walked or run, calorie consumption, quality of sleep and heart rate. Since accurate heart rate monitoring is essential in fitness training, the objective of this study was to assess the accuracy and precision of the Fitbit Charge 2 for measuring heart rate with respect to a gold standard electrocardiograph. Fifteen healthy participants were asked to ride a stationary bike for 10 minutes and their heart rate was simultaneously recorded from each device. Results showed that the Fitbit Charge 2 underestimates the heart rate. Although the mean bias in measuring heart rate was a modest -5.9 bpm (95% CI: -6.1 to -5.6 bpm), the limits of agreement, which indicate the precision of individual measurements, between the Fitbit Charge 2 and criterion measure were wide (+16.8 to -28.5 bpm) indicating that an individual heart rate measure could plausibly be underestimated by almost 30 bpm.


Subject(s)
Actigraphy/methods , Heart Rate , Monitoring, Physiologic , Humans
4.
Anticancer Res ; 36(10): 5163-5170, 2016 10.
Article in English | MEDLINE | ID: mdl-27798876

ABSTRACT

BACKGROUND: Generic anticancer drugs represent an opportunity in terms of cost savings but there are some concerns about their tolerability. The safety profiles of generic versus branded oxaliplatin formulations have never been studied in detail. PATIENTS AND METHODS: We tested in vitro concentrations, stability and efficacy of branded versus generic oxaliplatin formulations, then we retrospectively collected data about hypersensitivity reactions (HSR) of 427 colorectal cancer patients treated with oxaliplatin-based regimens. RESULTS: No significant difference in oxaliplatin concentration or time-dependent antiproliferative activity between branded and generic oxaliplatin was detected. The incidence of HSR was 12.1% (33/273 patients) in those treated with branded and 9.8% (15/154 patients) in those treated with generic oxaliplatin (p=0.46). The occurrence of grade III-IV HSRs and severe HSRs leading to oxaliplatin discontinuation were comparable. CONCLUSION: No difference between generic and branded formulations of oxaliplatin were demonstrated in preclinical nor in clinical settings. Generic oxaliplatin can be considered a safe alternative to branded formulation.


Subject(s)
Antineoplastic Agents/therapeutic use , Colorectal Neoplasms/drug therapy , Drugs, Generic/therapeutic use , Organoplatinum Compounds/therapeutic use , Adult , Aged , Aged, 80 and over , Antineoplastic Agents/adverse effects , Antineoplastic Agents/pharmacology , Caco-2 Cells , Cell Proliferation/drug effects , Drug Hypersensitivity/epidemiology , Drug Hypersensitivity/etiology , Drugs, Generic/adverse effects , Drugs, Generic/pharmacology , Female , Humans , Incidence , Male , Middle Aged , Organoplatinum Compounds/adverse effects , Organoplatinum Compounds/pharmacology , Oxaliplatin , Therapeutic Equivalency , Treatment Outcome , Young Adult
5.
PLoS One ; 8(12): e83676, 2013.
Article in English | MEDLINE | ID: mdl-24386252

ABSTRACT

The mass digitization of books is changing the way information is created, disseminated and displayed. Electronic book readers (e-readers) generally refer to two main display technologies: the electronic ink (E-ink) and the liquid crystal display (LCD). Both technologies have advantages and disadvantages, but the question whether one or the other triggers less visual fatigue is still open. The aim of the present research was to study the effects of the display technology on visual fatigue. To this end, participants performed a longitudinal study in which two last generation e-readers (LCD, E-ink) and paper book were tested in three different prolonged reading sessions separated by--on average--ten days. Results from both objective (Blinks per second) and subjective (Visual Fatigue Scale) measures suggested that reading on the LCD (Kindle Fire HD) triggers higher visual fatigue with respect to both the E-ink (Kindle Paperwhite) and the paper book. The absence of differences between E-ink and paper suggests that, concerning visual fatigue, the E-ink is indeed very similar to the paper.


Subject(s)
Asthenopia , Reading , Adult , Female , Humans , Male , Time Factors , Young Adult
6.
Appl Ergon ; 43(3): 486-92, 2012 May.
Article in English | MEDLINE | ID: mdl-21917238

ABSTRACT

In this study we compare the efficacy of three driver's performance indicators based on lateral deviation in detecting significant on-road performance degradations while interacting with a secondary task: the High Frequency Component of steering wheel (HFC), and two indicators described in ISO/DIS 26022 (2007): the Normative and the Adapted Lane Change Test (LCT). Sixteen participants were asked to perform a simulated lane-change task while interacting, when required, with a visual search task with two levels of difficulty. According to predictions, results showed that the Adapted LCT indicator, taking into consideration individual practices in performing the LCT, succeeded in discriminating between single and dual task conditions. Furthermore, this indicator was also able to detect whether the driver was interacting with an easy or a difficult secondary task. Despite predictions, results did not confirm Normative LCT and HFC to be reliable indicators of performance degradation within the simulated LCT.


Subject(s)
Automobile Driving , Task Performance and Analysis , Adult , Attention/physiology , Automobile Driving/psychology , Cognition/physiology , Computer Simulation , Decision Making , Female , Humans , Male , Reaction Time
SELECTION OF CITATIONS
SEARCH DETAIL
...