Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Vis Exp ; (105)2015 Nov 23.
Article in English | MEDLINE | ID: mdl-26651055

ABSTRACT

A major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15-1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection, system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.

2.
J Biomed Mater Res B Appl Biomater ; 90(1): 421-9, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19107804

ABSTRACT

Shape memory polymer stent prototypes were fabricated from thermoplastic polyurethane. Commercial stents are generally made of stainless steel or other alloys. These alloys are too stiff and prevent most stent designs from being able to navigate small and tortuous vessels to reach intracranial lesions. A solid tubular model and a high flexibility laser etched model are presented. The stents were tested for collapse in a pressure chamber. At 37 degrees C, the full collapse pressure was comparable to that of commercially available stents, and higher than the estimated maximum pressure exerted by intracranial arteries. However, there is a potential for onset of collapse, which needs further study. The stents were crimped and expanded, the laser-etched stent showed full recovery with an expansion ratio of 2.7 and a 1% axial shortening.


Subject(s)
Neovascularization, Physiologic , Polymers , Stents , Models, Theoretical , Pressure
3.
Biomed Eng Online ; 6: 43, 2007 Nov 27.
Article in English | MEDLINE | ID: mdl-18042294

ABSTRACT

BACKGROUND: Vascular stents are small tubular scaffolds used in the treatment of arterial stenosis (narrowing of the vessel). Most vascular stents are metallic and are deployed either by balloon expansion or by self-expansion. A shape memory polymer (SMP) stent may enhance flexibility, compliance, and drug elution compared to its current metallic counterparts. The purpose of this study was to describe the fabrication of a laser-activated SMP stent and demonstrate photothermal expansion of the stent in an in vitro artery model. METHODS: A novel SMP stent was fabricated from thermoplastic polyurethane. A solid SMP tube formed by dip coating a stainless steel pin was laser-etched to create the mesh pattern of the finished stent. The stent was crimped over a fiber-optic cylindrical light diffuser coupled to an infrared diode laser. Photothermal actuation of the stent was performed in a water-filled mock artery. RESULTS: At a physiological flow rate, the stent did not fully expand at the maximum laser power (8.6 W) due to convective cooling. However, under zero flow, simulating the technique of endovascular flow occlusion, complete laser actuation was achieved in the mock artery at a laser power of ~8 W. CONCLUSION: We have shown the design and fabrication of an SMP stent and a means of light delivery for photothermal actuation. Though further studies are required to optimize the device and assess thermal tissue damage, photothermal actuation of the SMP stent was demonstrated.


Subject(s)
Blood Vessel Prosthesis , Coated Materials, Biocompatible/chemistry , Lasers , Polymers/chemistry , Stents , Equipment Design , Equipment Failure Analysis , Molecular Conformation , Stainless Steel/chemistry
4.
IEEE Trans Biomed Eng ; 54(9): 1657-66, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17867358

ABSTRACT

An electromechanical microactuator comprised of shape memory polymer (SMP) and shape memory nickel-titanium alloy (nitinol) was developed and used in an endovascular thrombectomy device prototype. The microactuator maintains a straight rod shape until an applied current induces electro-resistive (Joule) heating, causing the microactuator to transform into a corkscrew shape. The straight-to-corkscrew transformation geometry was chosen to permit endovascular delivery through (straight form) and retrieval of (corkscrew form) a stroke-causing thrombus (blood clot) in the brain. Thermal imaging of the microactuator during actuation in air indicated that the steady-state temperature rise caused by Joule heating varied quadratically with applied current and that actuation occurred near the glass transition temperature of the SMP (86 degrees C). To demonstrate clinical application, the device was used to retrieve a blood clot in a water-filled silicone neurovascular model. Numerical modeling of the heat transfer to the surrounding blood and associated thermal effects on the adjacent artery potentially encountered during clinical use suggested that any thermal damage would likely be confined to localized areas where the microactuator was touching the artery wall. This shape memory mechanical thrombectomy device is a promising tool for treating ischemic stroke without the need for infusion of clot-dissolving drugs.


Subject(s)
Blood Vessel Prosthesis , Computer-Aided Design , Thrombectomy/instrumentation , Equipment Design , Equipment Failure Analysis , Pilot Projects , Thrombectomy/methods
5.
IEEE Trans Biomed Eng ; 54(9): 1722-4, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17867367

ABSTRACT

A deployable, shape memory polymer adapter is investigated for reducing the hemodynamic stress caused by dialysis needle flow impingement within an arteriovenous graft. Computational fluid dynamics simulations of dialysis sessions with and without the adapter demonstrate that the adapter provides a significant decrease in the wall shear stress. Preliminary in vitro flow visualization measurements are made within a graft model following delivery and actuation of a prototype shape memory polymer adapter. Both the simulations and the qualitative flow visualization measurements demonstrate that the adapter reduces the severity of the dialysis needle flow impingement on the vascular access graft.


Subject(s)
Anastomosis, Surgical/instrumentation , Blood Vessel Prosthesis , Dialysis/instrumentation , Needles , Polymers/chemistry , Biocompatible Materials/chemistry , Blood Pressure , Dialysis/methods , Elasticity , Equipment Design , Equipment Failure Analysis , Stress, Mechanical
6.
IEEE Trans Biomed Eng ; 54(6 Pt 2): 1157-60, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17549908

ABSTRACT

We demonstrate a new concept for endovascular embolization of nonnecked fusiform aneurysms. A device prototype consisting of a stent augmented with expandable foam, both made from shape memory polymer, was fabricated and deployed in an in vitro model. Visual observation indicated that the foam achieved embolization of the aneurysm while the stent maintained an open lumen in the parent artery. The shape memory polymer stent-foam device is a potential tool for treatment of nonnecked fusiform aneurysms, as well as an alternative to stent- and balloon-assisted coil embolization of wide-necked aneurysms.


Subject(s)
Aneurysm/therapy , Biocompatible Materials/chemistry , Blood Vessel Prosthesis , Embolization, Therapeutic/instrumentation , Polymers/chemistry , Stents , Elasticity , Embolization, Therapeutic/methods , Equipment Failure Analysis , Feasibility Studies , Humans , Prosthesis Design
7.
IEEE Trans Biomed Eng ; 53(10): 2075-83, 2006 Oct.
Article in English | MEDLINE | ID: mdl-17019872

ABSTRACT

Presently, there is interest in making medical devices such as expandable stents and intravascular microactuators from shape memory polymer (SMP). One of the key challenges in realizing SMP medical devices is the implementation of a safe and effective method of thermally actuating various device geometries in vivo. A novel scheme of actuation by Curie-thermoregulated inductive heating is presented. Prototype medical devices made from SMP loaded with nickel zinc ferrite ferromagnetic particles were actuated in air by applying an alternating magnetic field to induce heating. Dynamic mechanical thermal analysis was performed on both the particle-loaded and neat SMP materials to assess the impact of the ferrite particles on the mechanical properties of the samples. Calorimetry was used to quantify the rate of heat generation as a function of particle size and volumetric loading of ferrite particles in the SMP. These tests demonstrated the feasibility of SMP actuation by inductive heating. Rapid and uniform heating was achieved in complex device geometries and particle loading up to 10% volume content did not interfere with the shape recovery of the SMP.


Subject(s)
Biocompatible Materials/chemistry , Biocompatible Materials/radiation effects , Equipment and Supplies , Hot Temperature , Magnetics/instrumentation , Polymers/chemistry , Polymers/radiation effects , Equipment Design , Equipment Failure Analysis , Materials Testing
SELECTION OF CITATIONS
SEARCH DETAIL
...