Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Radiat Prot Dosimetry ; 144(1-4): 161-4, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21450701

ABSTRACT

The phototransferred thermoluminescence (PTTL) technique is applied to the Harshaw LiF:Mg,Cu,P material. It is demonstrated that using 254-nm UV light, dose levels as low as 0.2 mGy can be re-estimated. The PTTL efficiency was found to be ∼ 6 % in the dose range of 0.2 mGy-1 Gy, and it appears to be dose-independent. This implies that a simple calibration factor could be applied to the PTTL data for the re-estimation of dose levels. It was demonstrated that with a proper choice of the TL readout parameters, and the UV-light irradiation conditions, dose levels that are relevant to personal or environmental dosimetry can be re-estimated.


Subject(s)
Copper/analysis , Fluorides/analysis , Lithium Compounds/analysis , Magnesium/analysis , Phosphorus/analysis , Thermoluminescent Dosimetry/standards , Calibration , Dose-Response Relationship, Radiation , Environmental Monitoring/methods , Humans , Radiation Protection/methods , Radiometry/methods , Reproducibility of Results , Thermoluminescent Dosimetry/methods , Ultraviolet Rays
2.
Radiat Prot Dosimetry ; 144(1-4): 165-7, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21450702

ABSTRACT

This study investigates several sources of uncertainty associated with the application of optically stimulated luminescence (OSL) to personal dosimetry. A commercial OSL system based on Al(2)O(3):C was used for this study. First, it is demonstrated that the concept of repeated evaluation (readout) of the same dosemeter, often referred to as 're-analysis', can introduce uncertainty in the re-estimated dose. This uncertainty is associated with the fact that the re-analysis process depletes some of the populated traps, resulting in a continuous decrease of the OSL signal with each repeated reading. Furthermore, the rate of depletion may be dose-dependent. Second, it is shown that the previously reported light-induced fading in this system is the result of light leaks through miniature openings in the dosemeter badge.


Subject(s)
Radiation Monitoring/standards , Radiation Protection/standards , Radiometry/standards , Thermoluminescent Dosimetry/instrumentation , Data Interpretation, Statistical , Dose-Response Relationship, Radiation , Equipment Design , Humans , Light , Luminescence , Materials Testing , Radiation Dosage , Radiation Monitoring/methods , Radiation Protection/methods , Radiometry/methods , Reproducibility of Results , Thermoluminescent Dosimetry/methods , Thermoluminescent Dosimetry/standards , Uncertainty
3.
Inflamm Res ; 60(5): 409-24, 2011 May.
Article in English | MEDLINE | ID: mdl-21298317

ABSTRACT

BACKGROUND: Inflammation is a critical component of normal tissue repair, as well as being fundamental to the body's defense against infection. Environmental factors, such as smoking, have been reported to modify the host response and hence modify inflammation progression, severity and outcome. Therefore, a comprehensive understanding of the molecular mechanisms by which smoking affects inflammation is vital for preventive and therapeutic strategies on a clinical level. AIM: The purpose of the present article is to review the potential biological mechanisms by which smoking affects inflammation, emphasizing recent developments. RESULTS: Smoking is reported to effect a number of biological mediators of inflammation through its effect on immune-inflammatory cells, leading to an immunosuppressant state. Recent evidence strongly suggests that the molecular mechanisms behind the modulation of inflammation by smoking mainly involve the nuclear factor-kappa B (NF-kB) family, through the activation of both an inhibitor of IkB kinase (IKK)-dependent and -independent pathway. In addition to NF-kB activation, a number of transcriptional factors including GATA, PAX5 and Smad 3/4, have also been implicated. CONCLUSION: Multiple mechanisms may be responsible for the association of smoking and inflammation, and the identification of potential therapeutic targets should guide future research.


Subject(s)
Inflammation/etiology , Smoking/adverse effects , Animals , Cytokines/metabolism , DNA Damage , Female , Humans , I-kappa B Kinase/metabolism , Male , Mice , Models, Biological , NF-kappa B/metabolism , Nicotine/metabolism , Periodontal Diseases/metabolism , Receptors, Cholinergic/metabolism
4.
Radiat Prot Dosimetry ; 144(1-4): 199-201, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21310735

ABSTRACT

The effects of UV-induced bleaching of deep traps on Harshaw thermoluminescent (TL) LiF:Mg,Cu,P and LiF:Mg,Ti materials were investigated. During a normal heating cycle, LiF:Mg,Cu,P is limited to a maximum temperature of 240 °C. LiF:Mg,Ti can be read to higher temperatures; however, encapsulation in polytetrafluoroethylene limits the maximum readout temperature to 300 °C. Generally, for both materials, these respective temperatures are sufficient for emptying traps corresponding to the main dosemetric peaks. However, when the dosemeters are subjected to a high dose level, such as 1 Gy (much higher than individual monitoring dose levels), higher temperature traps are filled that cannot be emptied without exceeding the above-mentioned maximum temperatures. These high temperature traps tend to be unstable during normal readout and can significantly increase the residual TL signal. The purpose of this study was to investigate the applicability of a UV-induced bleaching technique for emptying higher temperature traps following high-dose applications. In addition, in the case of LiF:Mg,Cu,P, where the maximum readout temperature is significantly lower, we investigated the possibility of reducing the residual signal using the application of repeated readout cycles. The optical bleaching approach was found to be effective in the case of LiF:Mg,Ti; however, for LiF:Mg,Cu,P, no reduction in the residual signal was observed. For this latter material, the application of repeatable readout cycles is very effective and residual signals equivalent to dose levels as low as 0.01 mGy were observed following an initial dose of 5 Gy. To the best of our knowledge, this work is the first attempt to apply an 'optical annealing' technique to the Harshaw thermoluminescent dosemeter (TLD) materials.


Subject(s)
Copper/analysis , Fluorides/analysis , Lithium Compounds/analysis , Magnesium/analysis , Phosphorus/analysis , Radiation Monitoring/instrumentation , Radiation Protection/instrumentation , Thermoluminescent Dosimetry/instrumentation , Titanium/analysis , Calibration , Equipment Design , Humans , Light , Materials Testing , Radiation Monitoring/methods , Radiation Protection/methods , Temperature , Thermoluminescent Dosimetry/methods , Time Factors , Ultraviolet Rays
5.
Radiat Prot Dosimetry ; 144(1-4): 300-5, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21088021

ABSTRACT

The results of an intercomparison exercise within the US Navy dosimetric network (USN-DN) are presented and discussed. The USN-DN uses a commercially available LiF:Mg,Cu,P thermoluminescent dosemeter (TLD) model Harshaw 8840/8841 and TLD reader model Harshaw 8800 manufactured by Thermo Fisher Scientific. The USN-DN consists of a single calibration facility and 16 satellite dosimetry reading facilities throughout the world with ∼ 40 model 8800 TLD readers and in excess of 350 000 TLD cards in circulation. The Naval Dosimetry Center (NDC) is the primary calibration site responsible for the distribution and calibration of all TLD cards and their associated holders. In turn, each satellite facility is assigned a subpopulation of cards, which are utilised for servicing their local customers. Consistency of the NDC calibration of 150 dosemeters (calibrated at NDC) and 27 locally calibrated remote readers was evaluated in the framework of this intercomparison. Accuracy of TLDs' calibration, performed at the NDC, was found to be <3 % throughout the entire network. Accuracy of the readers' calibration, performed with the NDC issued calibration dosemeters at remote sites, was found to be better than 4 % for most readers. The worst performance was found for reader Channel 3, which is calibrated using the thinnest chip of the Harshaw 8840/8841 dosemeter. The loss of sensitivity of this chip may be caused by time-temperature profile that has been designed for all four chips without consideration of chip thickness.


Subject(s)
Radiation Protection/methods , Thermoluminescent Dosimetry/methods , Algorithms , Calibration , Equipment Design , Humans , Observer Variation , Radiation Dosage , Radiation Protection/instrumentation , Radiometry , Reproducibility of Results , Temperature , Thermoluminescent Dosimetry/instrumentation , Time Factors , United States
6.
Radiat Environ Biophys ; 48(3): 295-310, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19521713

ABSTRACT

The results of electron paramagnetic resonance (EPR) measurements in irradiated fingernails are presented. In total, 83 samples of different fingernails were studied. Five different groups of samples were selected based on the collection time of fingernail samples, their level of mechanical stress, and the number and size of clippings: (1) recently (<24 h) cut, irradiated and measured with EPR without any treatment of samples, and with rigorous control of size and number of clippings (stressed-fresh, controlled); (2) recently (<24 h) cut, irradiated and measured with EPR after application of a special treatment (10 min of water soaking, 5 min of drying time) to reduce the mechanical stress caused by cutting the samples, and with rigorous control of size and number of clippings (unstressed-fresh, controlled); (3) previously (>24 h) cut, stored at room temperature, additionally cut into small pieces immediately prior to study, irradiated and measured with EPR without any treatment of samples, and with rigorous control of size and number of clippings (stressed-old, controlled); (4) previously (>24 h) cut, stored at room temperature, additionally cut into small pieces immediately prior to the study, irradiated and measured with EPR after application of a special treatment to reduce mechanical stress caused by cut, and with rigorous control of size and number of clippings (unstressed-old, controlled); and (5) recently (<24 h) cut, irradiated and measured with EPR after application of a special treatment to reduce the mechanical stress caused by cut, and without rigorous control of size and number of clippings (unstressed-fresh, uncontrolled). Except for the fifth selected group, variability of the dose dependence inside all groups was found to be not statistically significant, although the variability among the different groups was significant. Comparison of the mean dose dependences obtained for each group allowed selection of key factors responsible for radiation sensitivity (dose response per unit of mass and dose) and the shape of dose dependence in fingernails. The major factor responsible for radiation sensitivity of fingernails was identified as their water content, which can affect radiation sensitivity up to 35%. The major factor responsible for the shape of the radiation sensitivity was identified as the mechanical stress. At a significant level of mechanical stress, the shape of the dose dependence is linear in the studied dose range (<20 Gy), and in lesser-stressed samples it is of an exponential growth including saturation, which depends on the degree of mechanical stress. In view of the findings, recommendations are discussed and presented for the appropriate protocol for EPR dose measurements in fingernails.


Subject(s)
Nails/radiation effects , Adult , Dose-Response Relationship, Radiation , Electron Spin Resonance Spectroscopy , Humans , Immersion , Middle Aged , Radiation Dosage , Stress, Mechanical , Temperature , Time Factors , Water , Young Adult
7.
Radiat Prot Dosimetry ; 131(3): 279-86, 2008.
Article in English | MEDLINE | ID: mdl-18621919

ABSTRACT

LiF thermoluminescent dosemeters (TLDs) are used by the US Navy to record radiation exposure of personnel. The Model DT-648 LiF:Mg,Ti TLD has been replaced by a new Model DT-702 LiF:Mg,Cu,P TLD. The DT-648 was used for many years and has undergone extensive testing to identify its pre- and post-irradiation fade operating characteristics. Studies have shown that the addition of copper increases the thermoluminesence sensitivity of the TLD for improved low-level radiation monitoring. This study evaluates various fading characteristics of the new copper-doped dosemeter using current equipment for processing of TLDs and calibrating to a National Institute of Standards and Technology standard source. The 57-week study took place at the Naval Dosimetry Center, Bethesda, MD, USA. TLDs were stored for various lengths of time before and after being exposed to a National Institute of Standards and Technology calibrated radiation sources. TLDs were then processed using current US Navy instructions and the resulting dose compared with the calibrated exposure. Both loss of signal and loss of sensitivity were evaluated. The results of this study have shown that the DT-702 TLD has no statistically significant change in sensitivity or change in signal with up to 57 weeks of pre- or post-irradiation time. The results of this study will increase the accuracy of exposure record keeping for the Navy and will allow longer issue periods. This will increase flexibility with international and domestic shipping procedures, as well as reduce workload requirements for dosimetry processing.


Subject(s)
Copper/radiation effects , Fluorides/radiation effects , Lithium Compounds/radiation effects , Magnesium/radiation effects , Phosphorus/radiation effects , Radiation Protection/instrumentation , Thermoluminescent Dosimetry/instrumentation , Thermoluminescent Dosimetry/trends , Calibration/standards , Dose-Response Relationship, Radiation , Humans , Radiation Protection/methods , Sensitivity and Specificity , Thermoluminescent Dosimetry/methods
8.
Radiat Environ Biophys ; 47(4): 515-26, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18584193

ABSTRACT

The most significant problem of electron paramagnetic resonance (EPR) fingernail dosimetry is the presence of two signals of non-radiation origin that overlap the radiation-induced signal (RIS), making it almost impossible to perform dose measurements below 5 Gy. Historically, these two non-radiation components were named mechanically induced signal (MIS) and background signal (BKS). In order to investigate them in detail, three different methods of MIS and BKS mutual isolation have been developed and implemented. After applying these methods, it is shown here that fingernail tissue, after cut, can be modeled as a deformed sponge, where the MIS and BKS are associated with the stress from elastic and plastic deformations, respectively. A sponge has a unique mechanism of mechanical stress absorption, which is necessary for fingernails in order to perform its everyday function of protecting the fingertips from hits and trauma. Like a sponge, fingernails are also known to be an effective water absorber. When a sponge is saturated with water, it tends to restore to its original shape, and when it loses water, it becomes deformed again. The same happens to fingernail tissue. It is proposed that the MIS and BKS signals of mechanical origin be named MIS1 and MIS2 for MISs 1 and 2, respectively. Our suggested interpretation of the mechanical deformation in fingernails gives also a way to distinguish between the MIS and RIS. The results obtained show that the MIS in irradiated fingernails can be almost completely eliminated without a significant change to the RIS by soaking the sample for 10 min in water. The proposed method to measure porosity (the fraction of void space in spongy material) of the fingernails gave values of 0.46-0.48 for three of the studied samples. Existing results of fingernail dosimetry have been obtained on mechanically stressed samples and are not related to the "real" in vivo dosimetric properties of fingernails. A preliminary study of these properties of pre-soaked (unstressed) fingernails has demonstrated their significant difference from fingernails stressed by cut. They show a higher stability signal, a less intensive non-radiation component, and a nonlinear dose dependence. The findings in this study set the stage for understanding fingernail EPR dosimetry and doing in vivo measurements in the future.


Subject(s)
Biological Assay/methods , Biomimetic Materials/chemistry , Electron Spin Resonance Spectroscopy/methods , Nails/chemistry , Radiometry/methods , Humans , Radiation Dosage , Relative Biological Effectiveness , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...