1.
J Cardiothorac Surg ; 7: 113, 2012 Oct 22.
Article in English | MEDLINE | ID: mdl-23088393

ABSTRACT

BACKGROUND: To evaluate, with different pacing modes, acute changes in left ventricular systolic function, obtained by continuous cardiac output thermodilution in various subsets of patients undergoing cardiopulmonary bypass surgery. Increments of mean arterial pressure and cardiac output were considered the end point. METHODS: Fifty cases electively submitted to cardiac surgery were analyzed. Isolated valve surgery 62%, coronary revascularization 30% and 8% mixed disease. Left ventricular ejection fraction was preserved in 50%,36% had moderate depression,(EF 36%-50%) whereas 14% had severe depression (EF < 35%). Left bundle branch block occurred in 18%. Preoperatively 84% were in sinus rhythm and 16% in atrial fibrillation. The different subgroups were analyzed for comparisons. Right atrial-right ventricular and right atrial-left ventricular pacing were employed in sinus rhytm. Biventricular pacing was also used in atrial fibrillation. RESULTS: Right atrium-right ventricular pacing, decreased significantly mean arterial pressure and cardiac output (2.3%) in the overall population and in the subgroups studied. Right atrium-left ventricle, increased mean arterial pressure and cardiac output in 79% of patients and yielded cardiac output increments of 7.5% (0.40 l/m) in the low ejection fraction subgroup and 7.3% (0.43 l/m) in the left bundle branch block subset. In atrial fibrillation patients, left ventricular and biventricular pacing produced a significant increase in cardiac output 8.5% (0.39 l/min) and 11.6% (0.53 l/min) respectively. The dP/dt max increased significantly with both modes (p = 0.021,p = 0.028). CONCLUSION: Right atrial-right ventricular pacing generated adverse hemodynamic effects. Right atrium-left ventricular pacing produced significant CO improvement particularly in cases with depressed ventricular function and left bundle branch block. The greatest increments were observed with left ventricular or biventricular pacing in atrial fibrillation with depressed ejection fraction.


Subject(s)
Cardiac Output/physiology , Cardiac Resynchronization Therapy/methods , Cardiopulmonary Bypass/methods , Aged , Blood Pressure/physiology , Female , Heart Rate/physiology , Humans , Male , Middle Aged , Statistics, Nonparametric
2.
Ann Thorac Surg ; 92(6): 2281-2, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22115253

ABSTRACT

Mechanical occlusion of the right coronary artery during aortic valve surgery is an infrequent but serious complication. Early recognition and expeditious management are important to reduce mortality. We developed a safe, quick, and easy technique to assess right coronary artery flow after aortic valve surgery. Direct intraoperative right coronary artery flow was measured by placing a transit-time flowmeter probe around the right coronary artery. We were able to promptly detect severe right coronary artery insufficiency in patients with acute unexpected right ventricular failure after aortic valve replacement.


Subject(s)
Aortic Valve/surgery , Coronary Circulation , Coronary Occlusion/diagnosis , Postoperative Complications/diagnosis , Echocardiography, Transesophageal , Humans
4.
Asian Cardiovasc Thorac Ann ; 18(1): 77-8, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20124304

ABSTRACT

A 50-year-old man with heart failure, systolic dysfunction, and abnormal septal motion underwent ventricular resynchronization. Postoperative clinical and echocardiographic improvement was observed. Several months later, he complained of worsening functional class after a traffic accident. Pacing lead fracture was diagnosed. After replacing the lead, improvement of clinical condition and ventricular parameters was achieved. The role of seat belts in causing dysfunction of pacemakers and resynchronization devices after deceleration injury is discussed.


Subject(s)
Accidents, Traffic , Cardiac Pacing, Artificial/methods , Deceleration/adverse effects , Pacemaker, Artificial , Seat Belts/adverse effects , Atrial Fibrillation/etiology , Echocardiography, Doppler , Electrocardiography , Equipment Failure , Follow-Up Studies , Heart/diagnostic imaging , Heart Failure/etiology , Humans , Male , Middle Aged , Radiography
5.
Eur J Cardiothorac Surg ; 36(6): 998-1005, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19581104

ABSTRACT

OBJECTIVE: To determine if preoperative statin treatment is associated with a reduction in systemic inflammatory response (SIR) and myocardial damage markers following cardiac surgery with cardiopulmonary bypass (CPB). METHODS: We study a prospective cohort of 138 patients who underwent coronary and valvular surgery with CPB. We differentiate two study groups: patients with (group A, n=72) or without (group B, n=66) statins. Plasma levels of pro-inflammatory interleukins (tumour necrosis factor-alpha (TNF-alpha), interleukin (IL)-6, IL-8 and IL-2R), creatine phosphokinase (CPK), CPK-MB and troponin I were measured before and 1, 6, 24 and >72 h after surgery. RESULTS: The baseline, operative and postoperative morbidity and mortality characteristics were similar for both the groups. Group A had significantly lower postoperative levels of IL-6 than group B at 6h (68.8+/-5 pg ml(-1) vs 108.9+/-108 pg ml(-1), p=0.01), 24h (71.7+/-7 pg ml(-1) vs 110.4+/-106 pg ml(-1), p=0.01) and before hospital discharge (21.6+/-12 pg ml(-1) vs 32.8+/-27 pg ml(-1), p=0.005), as well as significantly lower average IL-6 levels in the first 24h following surgery (71.8+/-5 pgml(-1) vs 112.8+/-82 pg ml(-1), p=0.002). The postoperative CPK-MB at 24h (19.7+/-23 ng ml(-1) vs 33.1+/-32 ng ml(-1), p=0.02) and troponin I levels at the end of the intervention (2.2+/-2.2 ng ml(-1) vs 3.3+/-3.1 ng ml(-1), p=0.03) and at 24h (4.1+/-3.5 ng ml(-1) vs 6.6+/-8 ng ml(-1), p=0.04) were also significantly lower in the group treated with statins prior to surgery. CONCLUSIONS: Preoperative treatment with statins is associated with a lower biochemical parameters of SIR and myocardial damage following cardiac surgery with CPB, regardless of it being coronary bypass grafting (CABG) or valvular surgery.


Subject(s)
Cardiac Surgical Procedures/adverse effects , Cardiopulmonary Bypass/adverse effects , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Systemic Inflammatory Response Syndrome/prevention & control , Aged , Biomarkers/metabolism , Blood Specimen Collection/methods , Drug Administration Schedule , Female , Heart Valves/surgery , Humans , Hydroxymethylglutaryl-CoA Reductase Inhibitors/administration & dosage , Inflammation Mediators/blood , Interleukin-6/blood , Male , Middle Aged , Postoperative Care/methods , Preanesthetic Medication/methods , Prospective Studies , Systemic Inflammatory Response Syndrome/etiology
6.
Interact Cardiovasc Thorac Surg ; 7(3): 373-6; discussion 376-7, 2008 May.
Article in English | MEDLINE | ID: mdl-18258649

ABSTRACT

The purpose of this study was to compare cardiac markers in the pericardial fluid and serum in order to evaluate preoperative myocardial injury. Thirty patients were divided into three groups. The first group (AVR; n=10) received an aortic valve replacement. The second group (SA; n=10) included patients with stable angina who underwent elective coronary artery bypass grafting (CABG). The third group (ACS; n=10) included patients with acute coronary syndrome who underwent urgent CABG. Pericardial fluid and venous samples were taken after opening the pericardium and 24 h postoperatively. Serum and pericardial concentration of troponin I (cTnI), creatine kinase (CK), its MB isoenzyme (CK-MB) and myoglobin were determined. Preoperative pericardial cTnI was significantly (P<0.01) higher than in serum in all groups. Preoperative pericardial CK, CK-MB and myoglobin were significantly (P<0.01) lower than in serum in groups AVR and SA. Preoperative pericardial and serum cTnI were significantly higher in the ACS than in AVR and SA groups (P<0.01). Postoperative pericardial concentration of all markers was significantly higher (P<0.01) than in serum in all groups. We conclude that preoperative pericardial accumulation of cTnI may reflect subclinical injury which may not be demonstrated by the usual laboratory tests.


Subject(s)
Aortic Valve/surgery , Biomarkers/metabolism , Coronary Artery Bypass , Extracellular Fluid/metabolism , Heart Valve Prosthesis Implantation , Myocardial Ischemia/surgery , Myocardium/metabolism , Pericardium/metabolism , Acute Coronary Syndrome/etiology , Acute Coronary Syndrome/surgery , Aged , Aged, 80 and over , Angina Pectoris/etiology , Angina Pectoris/surgery , Biomarkers/blood , Creatine Kinase/metabolism , Creatine Kinase, MB Form/metabolism , Elective Surgical Procedures , Emergency Treatment , Extracellular Fluid/enzymology , Female , Humans , Male , Middle Aged , Myocardial Ischemia/complications , Myocardial Ischemia/metabolism , Myocardial Ischemia/pathology , Myocardium/enzymology , Myocardium/pathology , Myoglobin/metabolism , Pericardium/enzymology , Prospective Studies , Time Factors , Treatment Outcome , Troponin I/metabolism
7.
Tex Heart Inst J ; 34(3): 376-8, 2007.
Article in English | MEDLINE | ID: mdl-17948093

ABSTRACT

Intraperitoneal migration of epicardial leads and abdominally placed generators is a potentially serious complication. We report the case of an 83-year-old man who experienced intraperitoneal migration of an epicardial pacing system and consequent small-bowel obstruction. Laparotomy was required in order to free constrictive lead adhesions. The patient's postoperative recovery was satisfactory after the placement of a new pacemaker generator in the abdominal wall. Predisposing factors are analyzed and the literature is reviewed in order to clarify the mechanisms of sequelae associated with the migration of epicardial pacemakers from the abdominal wall. To the best of our knowledge, this is the 1st report of pacemaker migration having caused bowel obstruction that required urgent laparotomy in an adult.


Subject(s)
Foreign-Body Migration/complications , Intestinal Obstruction/etiology , Peritoneum , Aged , Device Removal , Humans , Male
8.
J Heart Valve Dis ; 15(3): 446-51; discussion 451-2, 2006 May.
Article in English | MEDLINE | ID: mdl-16784087

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: The study aim was to evaluate the durability of the new Mitroflow 12A pericardial bioprosthesis and to assess ventricular mass regression after aortic valve replacement (AVR) in patients with small valves. METHODS: A total of 326 Mitroflow 12A pericardial bioprostheses was implanted without any other associated valve procedure. The mean patient age was 73.5 +/- 6.1 years; 252 patients (78.0%) were in NYHA class III/IV. Small valves (19 and 21 mm) were implanted in 212 patients (65.6%). The total follow up period was 837.1 patient-years (pt-yr). A subset of 61 patients with preoperative stenosis was selected and submitted to conventional echo-Doppler assessment at a mean period of 11.1 months after surgery. RESULTS: Hospital mortality was 8.6%. At eight years of follow up, survival was 57.1%. Freedom from structural valve deterioration (SVD) was 86.5% per pt-yr. Mean gradients were significantly reduced postoperatively for each valve size (to 18 +/- 8 mmHg for 19-mm valves and 12 +/- 4 mmHg for 25-mm valves). The effective orifice area (EOA) was also increased significantly for all valve sizes (to 1.1 +/- 0.1 cm2 for 19-mm valves and 1.8 +/- 0.2 cm2 for 25-mm valves). The left ventricular mass index (LVMI) decreased significantly, from 177 +/- 29 to 136 +/- 22 g/m2 for the 19-mm valve, and from 200 +/- 42 to 132 +/- 22 g/m2 for the 25-mm valve. The EOA index (EOAI) showed mismatch for the 19- and 21-mm valves (0.74 and 0.82 cm2/m2, respectively). The diagrammatic calculation between LVMI and relative wall thickness after surgery showed that 29.7% of patients achieved a normal pattern of remodeling (including 19- and 21-mm valves), despite various degrees of mismatch. CONCLUSION: The new Mitroflow 12A pericardial bioprosthesis showed an absence of mechanical failure after an eight-year follow up, with a satisfactory rate of SVD. Significant reductions in LVMI and improved ventricular geometry were observed, despite the small valve sizes implanted.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/instrumentation , Adult , Aged , Aged, 80 and over , Body Surface Area , Female , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Middle Aged , Prosthesis Failure , Reoperation/statistics & numerical data , Retrospective Studies , Survival Analysis , Survivors , Time Factors
9.
Eur J Cardiothorac Surg ; 29(4): 506-10, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16481181

ABSTRACT

OBJECTIVE: Apical suction devices allow displacement of the heart in off-pump coronary artery surgery. However, high vacuum pressure may injure the suctioned myocardium. It has been demonstrated that partial pressure of oxygen in the myocardium (ptiO(2)) is a sensitive and rapid indicator of myocardial ischemia. The purpose of this study is to evaluate the effect of apical suction on the ptiO(2) as an indirect measure of myocardial perfusion of the ventricular apex. METHODS: Twenty-six patients undergoing elective off-pump coronary surgery were studied. Intramyocardial ptiO(2) was continuously measured using a flexible catheter microprobe (Licox GMS mbH, Kiel, Germany). Patients were divided into two groups. In one group (Group A; n=14), the microprobe was intraoperatively inserted into the myocardium of the left ventricular apex. In the second group (Group B; n=12), the probe was inserted in the anterior wall of the left ventricle. Intramyocardial ptiO(2) monitoring was made with the heart in the resting position and after placing the apical suction device. RESULTS: In Group A, basal ptiO(2) was 15.3+/-7.4 mmHg. One minute after placing the apical suction device, the ptiO(2) significantly decreased to 2.3+/-1 mmHg (p<0.001). A progressive increase of ptiO(2) was observed immediately after the Xpose suction device was removed. ptiO(2) was 13.6+/-9.1 mmHg 5 min after releasing the suction cup and increased to 27.2+/-12.6 mmHg 20 min later. In Group B, basal ptiO(2) was 17+/-10.3 mmHg. No significant changes were observed in Group B after placing and removing the suction cup. CONCLUSIONS: Apical suction devices lead to severe ischemia of the suctioned myocardium. Collapse of coronary vessels due to vacuum pressure is a possible mechanism. Reperfusion occurs immediately after removing the suction cup and a significant reactive hyperemia is observed.


Subject(s)
Coronary Artery Bypass, Off-Pump/adverse effects , Myocardial Ischemia/etiology , Aged , Electrocardiography , Female , Hemodynamics , Humans , Male , Middle Aged , Myocardial Ischemia/blood , Oxygen/blood , Partial Pressure , Prospective Studies , Suction/adverse effects
15.
Rev Esp Cardiol ; 57(4): 313-9, 2004 Apr.
Article in English, Spanish | MEDLINE | ID: mdl-15104985

ABSTRACT

BACKGROUND AND OBJECTIVES: Cardiac resynchronization via left ventricular or biventricular pacing is an option for selected patients with ventricular systolic dysfunction and widened QRS complex. Stimulation through a coronary vein is the technique of choice for left ventricular pacing, but this approach results in a failure rate of approximately 8%. We describe our initial experience with minimally invasive surgical implantation of left ventricular epicardial leads using video-assisted thoracoscopy. PATIENTS AND METHOD: A total of 14 patients with congestive heart failure, NYHA functional class 3.2 (0.6) and mean ejection fraction 22.9 (6.8)% were included in this study. Left bundle branch block, QRS complex >140 ms and abnormal septal motion were observed in all cases. Epicardial leads were implanted on the left ventricular free wall under general anesthesia using video-assisted thoracoscopic surgery. RESULTS: Lead implantation was successful in 13 patients. Conversion to a small thoracotomy was necessary in one patient. All patients were extubated in the operating room. None of the patients died during their hospital stay. Follow-up showed reversal of ventricular asynchrony and significant improvement in ejection fraction and functional class. CONCLUSIONS: Minimally invasive surgery for ventricular resynchronization using video-assisted thoracoscopy in selected patients is a safe procedure that makes it possible to choose the best site for lead implantation and provides adequate short- and medium-term stimulation.


Subject(s)
Cardiac Pacing, Artificial , Heart Failure/therapy , Pacemaker, Artificial , Thoracic Surgery, Video-Assisted , Adult , Aged , Female , Humans , Male , Middle Aged
16.
Tex Heart Inst J ; 31(4): 439-41, 2004.
Article in English | MEDLINE | ID: mdl-15745301

ABSTRACT

Immunosuppression can allow organisms that are not usually pathogenetic to cause disease; under such circumstances, Aspergillus species frequently form large masses of fungal elements. We describe the case of a 12-year-old girl with hematologic remission of leukemia. She had a left ventricular pedunculated mass that was detected by echocardiographic study; at surgery, the presence of Aspergillus terreus was confirmed.


Subject(s)
Aspergillosis/diagnostic imaging , Heart Diseases/microbiology , Aspergillosis/surgery , Child , Female , Heart Diseases/diagnostic imaging , Heart Diseases/surgery , Heart Ventricles/diagnostic imaging , Heart Ventricles/microbiology , Heart Ventricles/pathology , Humans , Ultrasonography