Anesthesiology ; 140(6): 1153-1164, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38271619

ABSTRACT

BACKGROUND: Unfractionated heparin, administered during venoarterial extracorporeal membrane oxygenation to prevent thromboembolic events, largely depends on plasma antithrombin for its antithrombotic effects. Decreased heparin responsiveness seems frequent on extracorporeal membrane oxygenation; however, its association with acquired antithrombin deficiency is poorly understood. The objective of this study was to describe longitudinal changes in plasma antithrombin levels during extracorporeal membrane oxygenation support and evaluate the association between antithrombin levels and heparin responsiveness. The hypothesis was that extracorporeal membrane oxygenation support would be associated with acquired antithrombin deficiency and related decreased heparin responsiveness. METHODS: Adults receiving venoarterial extracorporeal membrane oxygenation were prospectively included. All patients received continuous intravenous unfractionated heparin using a standardized protocol (target anti-Xa 0.3 to 0.5 IU/ml). For each patient, arterial blood was withdrawn into citrate-containing tubes at 11 time points (from hour 0 up to day 7). Anti-Xa (without dextran or antithrombin added) and antithrombin levels were measured. The primary outcome was the antithrombin plasma level. In the absence of consensus, antithrombin deficiency was defined as a time-weighted average of antithrombin less than or equal to 70%. Data regarding clinical management and heparin dosage were collected. RESULTS: Fifty patients, including 42% postcardiotomy, were included between April 2020 and May 2021, with a total of 447 samples. Median extracorporeal membrane oxygenation duration was 7 (interquartile range, 4 to 12) days. Median antithrombin level was 48% (37 to 60%) at baseline. Antithrombin levels significantly increased throughout the follow-up. Time-weighted average of antithrombin levels was 63% (57 to 73%) and was less than or equal to 70% in 32 (64%) of patients. Overall, 45 (90%) patients had at least one antithrombin value less than 70%, and 35 (70%) had at least one antithrombin value less than 50%. Antithrombin levels were not significantly associated with heparin responsiveness evaluated by anti-Xa assay or heparin dosage. CONCLUSIONS: Venoarterial extracorporeal membrane oxygenation support was associated with a moderate acquired antithrombin deficiency, mainly during the first 72 h, that did not correlate with heparin responsiveness.


Subject(s)
Anticoagulants , Antithrombins , Extracorporeal Membrane Oxygenation , Heparin , Humans , Extracorporeal Membrane Oxygenation/methods , Heparin/administration & dosage , Heparin/pharmacology , Prospective Studies , Male , Female , Antithrombins/blood , Middle Aged , Anticoagulants/administration & dosage , Anticoagulants/pharmacology , Cohort Studies , Adult , Aged
2.
Anaesth Crit Care Pain Med ; 40(4): 100907, 2021 08.
Article in English | MEDLINE | ID: mdl-34153533

ABSTRACT

OBJECTIVE: Discuss if the use of disposable or reusable medical devices leads to a difference in terms of hospital-acquired infection or bacterial contamination. Determine which solution is less expensive and has less environmental impact in terms of carbon footprint, energy and water consumption and amount of waste. METHODS: We carried out a narrative review. Articles published in English and French from January 2000 to April 2020 were identified from PubMed. RESULTS: We retrieved 81 articles, including 12 randomised controlled trial, 21 literature reviews, 13 descriptive studies, 6 experimental studies, 9 life-cycle studies, 6 cohort studies, 2 meta-analysis, 4 case reports and 8 other studies. It appears that pathogen transmission in the anaesthesia work area is mainly due to the lack of hand hygiene among the anaesthesia team. The benefit of single-use devices on infectious risk is based on weak scientific arguments, while reusable devices have benefits in terms of costs, water consumption, energy consumption, waste, and reducing greenhouse gas emissions. CONCLUSION: Disposable medical devices and attire in the operating theatre do not mitigate the infectious risk to the patients but have a greater environmental, financial and social impact than the reusable ones. This study is the first step towards recommendations for more environmental-friendly practices in the operating theatre.


Subject(s)
Anesthesia , Anesthesiology , Greenhouse Gases , Anesthesia/adverse effects , Carbon Footprint , Humans , Patient Safety
SELECTION OF CITATIONS