Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Clin Chem Lab Med ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38738903

ABSTRACT

OBJECTIVES: Heparin is a highly charged polysaccharide used as an anticoagulant to prevent blood coagulation in patients with presumed myocardial infarction and to prepare heparin plasma samples for laboratory tests. There are conflicting data regarding the effects of heparin on the measurement of cardiac isoforms of troponin I (cTnI) and troponin T (cTnT), which are used for the immunodiagnosis of acute myocardial infarction. In this study, we investigated the influence of heparin on the immunodetection of human cardiac troponins. METHODS: Gel filtration (GF) techniques and sandwich fluoroimmunoassay were performed. The regions of сTnI and cTnT that are affected by heparin were investigated with a panel of anti-cTnI and anti-cTnT monoclonal antibodies, specific to different epitopes. RESULTS: Heparin was shown to bind to the human cardiac full-size ternary troponin complex (ITC-complex) and free cTnT, which increased their apparent molecular weights in GF studies. Heparin did not bind to the low molecular weight ITC-complex and to binary cTnI-troponin С complex. We did not detect any sites on cTnI in the ITC-complex that were specifically affected by heparin. In contrast, cTnT regions limited to approximately 69-99, 119-138 and 145-164 amino acid residues (aar) in the ITC-complex and a region that lies approximately between 236 and 255 aar of free cTnT were prone to heparin influence. CONCLUSIONS: Heparin binds to the ITC-complex via cTnT, interacting with several sites on the N-terminal and/or central parts of the cTnT molecule, which might influence the immunodetection of analytes in human blood.

2.
Clin Chim Acta ; 542: 117281, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36918061

ABSTRACT

BACKGROUND: Blood measurement of cardiac troponin T (cTnT) is one of the most widespread methods of acute myocardial infarction (MI) diagnosis. cTnT degradation may have a significant influence on the precision of cTnT immunodetection; however, there are no consistent data describing the level and sites of cTnT proteolysis in the blood of MI patients. In this study, we bordered major cTnT fragments and quantified their relative abundance in the blood at different times after MI. METHODS: Serial heparin plasma samples were collected from 37 MI patients 2-37 h following the onset of MI. cTnT and its fragments were studied by western blotting and immunofluorescence analysis using monoclonal antibodies specific to various cTnT epitopes. RESULTS: cTnT was present in the blood of MI patients as 23 proteolytic fragments with an apparent molecular mass of âˆ¼ 8-37 kDa. Two major sites of cTnT degradation were identified: between amino acid residues (aar) 68 and 69 and between aar 189 and 223. Analysis of the abundance of cTnT fragments showed an increase in the fraction of free central fragments in the first few hours after MI, while the fraction of the C-terminal fragments of cTnT remained almost unchanged. CONCLUSION: cTnT progressively degrades after MI and appears in the blood as a mixture of 23 proteolytic fragments. The cTnT region approximately bordered by aar 69-158 is a promising target for antibodies used for measurement of total cTnT.


Subject(s)
Myocardial Infarction , Troponin T , Humans , Blotting, Western , Proteolysis , Heparin , Biomarkers
3.
Clin Chem ; 65(7): 882-892, 2019 07.
Article in English | MEDLINE | ID: mdl-30858159

ABSTRACT

BACKGROUND: The measurement of cardiac isoforms of troponin I (cTnI) and troponin T (cTnT) is widely used for the diagnosis of acute myocardial infarction (AMI). However, there are conflicting data regarding what forms of cTnI and cTnT are present in the blood of AMI patients. We investigated cTnI and cTnT as components of troponin complexes in the blood of AMI patients. METHODS: Gel filtration techniques, sandwich fluoroimmunoassays, and Western blotting were used. RESULTS: Plasma samples from patients with AMI contained the following troponin complexes: (a) a cTnI-cTnT-TnC complex (ITC) composed of full-size cTnT of 37 kDa or its 29-kDa fragment and full-size cTnI of 29 kDa or its 27-kDa fragments; (b) ITC with lower molecular weight (LMW-ITC) in which cTnT was truncated to the 14-kDa C-terminal fragments; and (c) a binary cTnI-cTnC complex composed of truncated cTnI of approximately 14 kDa. During the progression of the disease, the amount of ITC in AMI samples decreased, whereas the amounts of LMW-ITC and short 16- to 20-kDa cTnT central fragments increased. Almost all full-size cTnT and a 29-kDa cTnT fragment in AMI plasma samples were the components of ITC. No free full-size cTnT was found in AMI plasma samples. Only 16- to 27-kDa central fragments of cTnT were present in a free form in patient blood. CONCLUSIONS: A ternary troponin complex exists in 2 forms in the blood of patients with AMI: full-size ITC and LMW-ITC. The binary cTnI-cTnC complex and free cTnT fragments are also present in patient blood.


Subject(s)
Myocardial Infarction/blood , Troponin I/blood , Troponin T/blood , Acute Disease , Adult , Humans
4.
Clin Chem ; 64(7): 1104-1112, 2018 07.
Article in English | MEDLINE | ID: mdl-29632125

ABSTRACT

BACKGROUND: In the blood of patients with acute myocardial infarction (AMI), cardiac troponin I (cTnI) presents as an intact molecule with a repertoire of proteolytic fragments. The degradation of cTnI might negatively influence its precise immunodetection. In this study we identified cTnI fragments and calculated their ratio in the blood of patients at different times after AMI to discriminate the most stable part(s) of cTnI. METHODS: Serial serum samples were collected from AMI patients within 1 to 36 h after the onset of chest pain both before and after stenting. cTnI and its fragments were immunoextracted from serum samples and analyzed by Western blotting with monoclonal antibodies (mAbs) specific to the different epitopes of cTnI and by 2 in-house immunoassays specific to the central and terminal portions of cTnI. RESULTS: Intact cTnI and its 11 major fragments were detected in blood of AMI patients. The ratio of the fragments in serial samples did not show large changes in the period 1-36 h after AMI. mAbs specific to the epitopes located approximately between amino acid residues (aar) 34 and 126 stained all extracted cTnI. mAbs specific to aar 23-36 and 126-196 recognized approximately 80% to 90% (by abundance) of cTnI. CONCLUSIONS: In addition to mAbs specific to the central part of cTnI (approximately aar 34-126), antibodies specific to the adjacent epitopes (approximately aar 23-36 and 126-196) could be used in assays because they recognize ≥80% of cTnI in patients' blood samples within the first 36 h after AMI.


Subject(s)
Antibodies, Monoclonal/immunology , Immunoassay/methods , Myocardial Infarction/blood , Troponin I/blood , Troponin I/immunology , Blotting, Western , Coronary Angiography , Humans , Proteolysis , Stents
6.
Clin Chem ; 63(6): 1094-1100, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28428352

ABSTRACT

BACKGROUND: Cardiac troponin T (cTnT) is an acknowledged biomarker of acute myocardial infarction (AMI) that is known to be prone to proteolytic degradation in serum. Such degradation is usually explained by the action of µ-calpain, although there could be other candidates for that role. In the current study, we explored the hypothesis that thrombin-mediated cTnT cleavage occurs as a result of the serum sample preparation. METHODS: cTnT degradation was studied by using immunoblotting and mass spectrometry (MS) analysis. RESULTS: The comparison of cTnT isolated from AMI heparin plasma and serum samples showed that cTnT in the plasma samples was mainly present as the full-sized molecule (approximately 35 kDa), while in serum samples it was present as a 29-kDa fragment. The incubation of recombinant cTnT, or native ternary cardiac troponin complex with thrombin or in normal human serum (NHS), resulted in the formation of a 29-kDa product that was similar to that detected in AMI serum samples. No cTnT degradation was observed when thrombin or NHS was pretreated with hirudin, a specific inhibitor of thrombin, or during incubation of troponin in normal heparin plasma. When the products of thrombin-mediated cTnT proteolysis were analyzed by MS, 2 fragments consisting of amino acid residues (aar) 2-68 and 69-288 were identified, which suggests that thrombin cleaves cTnT between R68 and S69. CONCLUSIONS: The results of this study suggest that the 29-kDa fragment of cTnT in AMI serum samples mainly appears due to the cleavage by thrombin during serum sample preparation.


Subject(s)
Thrombin/metabolism , Troponin T/metabolism , Acute Disease , Biomarkers/blood , Biomarkers/metabolism , Humans , Immunoblotting , Mass Spectrometry , Myocardial Infarction/blood , Myocardial Infarction/metabolism , Troponin T/blood
7.
Clin Chem ; 63(1): 343-350, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27815308

ABSTRACT

BACKGROUND: Autoantibodies to cardiac troponins (TnAAbs) could negatively affect cardiac troponin I (cTnI) measurements by TnAAbs-sensitive immunoassays. We investigated the epitope specificity of TnAAbs and its influence on cTnI immunodetection in patients with acute myocardial infarction (AMI). METHODS: The specificity of TnAAbs was studied in immunoassays and gel-filtration experiments. The influence of TnAAbs on endogenous troponin measurements was studied in 35 plasma samples from 15 patients with AMI. RESULTS: The inhibitory effect of TnAAbs on the cTnI immunodetection was observed only for the ternary cardiac troponin complex (I-T-C) and not for the binary cardiac troponin complex (I-C) or free cTnI. In the same TnAAbs-containing samples, the immunodetection of cardiac troponin T (cTnT) added in the form of I-T-C (but not free cTnT) was also inhibited in the assays that used monoclonal antibodies (mAbs) specific to the 223-242 epitope. The negative effects of TnAAbs on the measurements of endogenous cTnI in AMI samples were less than on the measurements of isolated I-T-C and decreased with time after the onset of symptoms. Early AMI blood samples might contain a mixture of the I-T-C and I-C complexes with the ratio gradually changing with the progression of the disease in favor of I-C. CONCLUSIONS: The investigated TnAAbs are specific to the structural epitopes formed by cTnI and cTnT molecules in the I-T-C complex. AMI blood samples contain a mixture of I-C and I-T-C complexes. The concentrations of total cTnI at the early stage of AMI could be underestimated in approximately 5%-10% of patients if measured by TnAAbs-sensitive immunoassays.


Subject(s)
Autoantibodies/immunology , Epitopes/immunology , Myocardial Infarction/immunology , Troponin I/immunology , Troponin T/immunology , Acute Disease , Adult , Antigen-Antibody Reactions , Autoantibodies/blood , Epitopes/blood , Healthy Volunteers , Humans , Immunoassay , Middle Aged , Myocardial Infarction/blood , Myocardial Infarction/diagnosis , Troponin I/blood , Troponin T/blood , Young Adult
8.
Blood Coagul Fibrinolysis ; 27(5): 542-50, 2016 Jul.
Article in English | MEDLINE | ID: mdl-26656897

ABSTRACT

Fibrin degradation results in the formation of fibrin degradation products (FDPs) of different molecular weights, which include D-dimer. Commercial D-dimer assays recognize multiple forms of FDP with different specificity. As a result, the absence of an international D-dimer standard and the marked discrepancy in the D-dimer values in the same samples measured by assays from different manufacturers have become the primary problems that clinicians face in the D-dimer determination. We consider that an assay with equal specificity to all FDP forms regardless of their molecular weights could help to solve these problems. We aimed to produce mAbs that could equally recognize high-molecular-weight FDP (HMW FDP) and D-dimer. mAbs against D-dimer were produced. The HMW FDP/D-dimer ratios in plasma samples were analyzed following protein separation by gel filtration using the developed fluoroimmunoassay. A sandwich immunoassay with equal specificity to HMW FDP and D-dimer was developed and applied to determine HMW FDP/D-dimer ratios in patients with different diseases. Although the HMW FDP levels prevailed in thrombotic patients, the FDP and D-dimer levels were comparable in septic patients. Meanwhile, the D-dimer levels often exceeded the HMW FDP levels in patients who had undergone surgery. The 'D-dimer' levels that were detected by different assays also varied greatly depending on the assay specificities to FDP and D-dimer. Our findings show that the introduction of assays with equal specificities to FDP and D-dimer in clinical practice is a possible way of standardizing D-dimer measurements.


Subject(s)
Antibodies, Monoclonal/chemistry , Fibrin Fibrinogen Degradation Products/analysis , Immunoassay/standards , Sepsis/blood , Venous Thrombosis/blood , Abdominal Cavity/surgery , Animals , Antibodies, Monoclonal/biosynthesis , Antibodies, Monoclonal/isolation & purification , Antibody Specificity , Fibrin/chemistry , Fibrin/metabolism , Fibrinolysis , Humans , Hybridomas/immunology , Hybridomas/metabolism , Immunoassay/methods , Mice , Mice, Inbred BALB C , Molecular Weight , Reagent Kits, Diagnostic , Sepsis/diagnosis , Sepsis/immunology , Spleen/immunology , Spleen/metabolism , Venous Thrombosis/diagnosis , Venous Thrombosis/immunology
10.
Clin Biochem ; 44(2-3): 257-9, 2011 Feb.
Article in English | MEDLINE | ID: mdl-20950595

ABSTRACT

OBJECTIVES: To compare plasma BNP values determined by a conventional-type and a novel-type of BNP assays. DESIGN AND METHODS: Plasma samples (n=94) from HF patients were analyzed by the novel-type "Single Epitope Sandwich" (SES assay prototype) and the conventional-type Siemens ADVIA Centaur BNP assays. Both assays were calibrated using recombinant proBNP (expressed in E. coli). RESULTS: The SES assay measured 1.2- to 7.2-fold (2.1±0.9; mean, SD) greater BNP concentrations compared to the Siemens assay. A subset of six samples (6.4%) demonstrated the largest (3- to 7.2-fold higher) difference. CONCLUSIONS: The SES prototype assay appears to more accurately measure the absolute concentrations of BNP immunoreactive forms.


Subject(s)
Escherichia coli , Natriuretic Peptide, Brain , Antibodies , Epitopes/immunology , Humans , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...