Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Biomed Eng Online ; 12: 133, 2013 Dec 27.
Article in English | MEDLINE | ID: mdl-24369728

ABSTRACT

BACKGROUND: The information of electromyographic signals can be used by Myoelectric Control Systems (MCSs) to actuate prostheses. These devices allow the performing of movements that cannot be carried out by persons with amputated limbs. The state of the art in the development of MCSs is based on the use of individual principal component analysis (iPCA) as a stage of pre-processing of the classifiers. The iPCA pre-processing implies an optimization stage which has not yet been deeply explored. METHODS: The present study considers two factors in the iPCA stage: namely A (the fitness function), and B (the search algorithm). The A factor comprises two levels, namely A1 (the classification error) and A2 (the correlation factor). Otherwise, the B factor has four levels, specifically B1 (the Sequential Forward Selection, SFS), B2 (the Sequential Floating Forward Selection, SFFS), B3 (Artificial Bee Colony, ABC), and B4 (Particle Swarm Optimization, PSO). This work evaluates the incidence of each one of the eight possible combinations between A and B factors over the classification error of the MCS. RESULTS: A two factor ANOVA was performed on the computed classification errors and determined that: (1) the interactive effects over the classification error are not significative (F0.01,3,72 = 4.0659 > fAB = 0.09), (2) the levels of factor A have significative effects on the classification error (F0.02,1,72 = 5.0162 < fA = 6.56), and (3) the levels of factor B over the classification error are not significative (F0.01,3,72 = 4.0659 > fB = 0.08). CONCLUSIONS: Considering the classification performance we found a superiority of using the factor A2 in combination with any of the levels of factor B. With respect to the time performance the analysis suggests that the PSO algorithm is at least 14 percent better than its best competitor. The latter behavior has been observed for a particular configuration set of parameters in the search algorithms. Future works will investigate the effect of these parameters in the classification performance, such as length of the reduced size vector, number of particles and bees used during optimal search, the cognitive parameters in the PSO algorithm as well as the limit of cycles to improve a solution in the ABC algorithm.


Subject(s)
Algorithms , Electromyography/methods , Principal Component Analysis , Signal Processing, Computer-Assisted
2.
Biomed Eng Online ; 9: 5, 2010 Jan 15.
Article in English | MEDLINE | ID: mdl-20078864

ABSTRACT

BACKGROUND: Two-dimensional echocardiography (2D-echo) allows the evaluation of cardiac structures and their movements. A wide range of clinical diagnoses are based on the performance of the left ventricle. The evaluation of myocardial function is typically performed by manual segmentation of the ventricular cavity in a series of dynamic images. This process is laborious and operator dependent. The automatic segmentation of the left ventricle in 4-chamber long-axis images during diastole is troublesome, because of the opening of the mitral valve. METHODS: This work presents a method for segmentation of the left ventricle in dynamic 2D-echo 4-chamber long-axis images over the complete cardiac cycle. The proposed algorithm is based on classic image processing techniques, including time-averaging and wavelet-based denoising, edge enhancement filtering, morphological operations, homotopy modification, and watershed segmentation. The proposed method is semi-automatic, requiring a single user intervention for identification of the position of the mitral valve in the first temporal frame of the video sequence. Image segmentation is performed on a set of dynamic 2D-echo images collected from an examination covering two consecutive cardiac cycles. RESULTS: The proposed method is demonstrated and evaluated on twelve healthy volunteers. The results are quantitatively evaluated using four different metrics, in a comparison with contours manually segmented by a specialist, and with four alternative methods from the literature. The method's intra- and inter-operator variabilities are also evaluated. CONCLUSIONS: The proposed method allows the automatic construction of the area variation curve of the left ventricle corresponding to a complete cardiac cycle. This may potentially be used for the identification of several clinical parameters, including the area variation fraction. This parameter could potentially be used for evaluating the global systolic function of the left ventricle.


Subject(s)
Algorithms , Echocardiography/methods , Heart Ventricles/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Pattern Recognition, Automated/methods , Humans , Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity
3.
Article in English | MEDLINE | ID: mdl-19963967

ABSTRACT

We present a new preprocessing technique for two-dimensional compression of surface electromyographic (S-EMG) signals, based on correlation sorting. We show that the JPEG2000 coding system (originally designed for compression of still images) and the H.264/AVC encoder (video compression algorithm operating in intraframe mode) can be used for compression of S-EMG signals. We compare the performance of these two off-the-shelf image compression algorithms for S-EMG compression, with and without the proposed preprocessing step. Compression of both isotonic and isometric contraction S-EMG signals is evaluated. The proposed methods were compared with other S-EMG compression algorithms from the literature.


Subject(s)
Algorithms , Data Compression/methods , Diagnosis, Computer-Assisted/methods , Electromyography/methods , Muscle Contraction/physiology , Muscle, Skeletal/physiology , Adult , Humans , Male , Reproducibility of Results , Sensitivity and Specificity , Statistics as Topic
SELECTION OF CITATIONS
SEARCH DETAIL
...