Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Curr Oncol ; 30(5): 5116-5134, 2023 05 17.
Article in English | MEDLINE | ID: mdl-37232845

ABSTRACT

This pilot study sought to evaluate the circulating levels of immune cells, particularly regulatory T-cell (Treg) subsets, before and after lung resection for non-small cell lung cancer. Twenty-five patients consented and had specimens collected. Initially, peripheral blood of 21 patients was collected for circulating immune cell studies. Two of these patients were excluded due to technical issues, leaving 19 patients for the analyses of circulating immune cells. Standard gating and high-dimensional unsupervised clustering flow cytometry analyses were performed. The blood, tumors and lymph nodes were analyzed via single-cell RNA and TCR sequencing for Treg analyses in a total of five patients (including four additional patients from the initial 21 patients). Standard gating flow cytometry revealed a transient increase in neutrophils immediately following surgery, with a variable neutrophil-lymphocyte ratio and a stable CD4-CD8 ratio. Unexpectedly, the total Treg and Treg subsets did not change with surgery with standard gating in short- or long-term follow-up. Similarly, unsupervised clustering of Tregs revealed a dominant cluster that was stable perioperatively and long-term. Two small FoxP3hi clusters slightly increased following surgery. In the longer-term follow-up, these small FoxP3hi Treg clusters were not identified, indicating that they were likely a response to surgery. Single-cell sequencing demonstrated six CD4+FoxP3+ clusters among the blood, tumors and lymph nodes. These clusters had a variable expression of FoxP3, and several were mainly, or only, present in tumor and lymph node tissue. As such, serial monitoring of circulating Tregs may be informative, but not completely reflective of the Tregs present in the tumor microenvironment.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Humans , Carcinoma, Non-Small-Cell Lung/pathology , Lung Neoplasms/pathology , Pilot Projects , Forkhead Transcription Factors/metabolism , Lung/pathology , Tumor Microenvironment
2.
J Biomol Tech ; 33(1)2022 04 15.
Article in English | MEDLINE | ID: mdl-35837003

ABSTRACT

Cells isolated using electrostatic cell sorters are subsequently evaluated in a variety of in vitro and in vivo applications. Thus, manipulations to the cells during the pre- and post-sort processing as well as when the cells are being analyzed by and passing through the sorter fluidics has the potential to affect the experimental results. There are many variables to consider when seeking to preserve cellular integrity and function during the cell-sorting process. A previous study by the Association of Biomolecular Resource Facilities Flow Cytometry Research Group (FCRG) investigated downstream effects on different cell types as a function of sorting variables such as pressure, nozzle size, and temperature. This multisite study revealed site-to-site variability based on differential gene expression when the same cell type and sort conditions were used. These results indicated the possibility that environmental factors such as the presence of contaminants in the sorter fluidics could exhibit effects on downstream molecular assays (ie, endotoxins or RNases). In the study described here, the FCRG sought to better understand how sorters are maintained and evaluated for contaminants such as bacteria, endotoxin, and RNases. In addition, the efficacy of an endotoxin decontamination method was evaluated. The results demonstrated that the majority of sorters in shared resource laboratories are free of RNase activity and bacteria; however, many are contaminated with endotoxin. The efficacy of a hydrogen peroxide cleaning procedure was tested and found to exhibit only a short-term effectiveness in eliminating endotoxin contamination.


Subject(s)
Infertility , Laboratories , Cell Separation/methods , Endotoxins/genetics , Flow Cytometry/methods , Humans
3.
Sci Immunol ; 7(73): eabq3511, 2022 07 29.
Article in English | MEDLINE | ID: mdl-35549299

ABSTRACT

Understanding immune responses after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) breakthrough infection will facilitate the development of next-generation vaccines. Here, we profiled spike (S)-specific B cell responses after Omicron/BA.1 infection in messenger RNA-vaccinated donors. The acute antibody response was characterized by high levels of somatic hypermutation and a bias toward recognition of ancestral SARS-CoV-2 strains, suggesting the early activation of vaccine-induced memory B cells. BA.1 breakthrough infection induced a shift in B cell immunodominance hierarchy from the S2 subunit, which is highly conserved across SARS-CoV-2 variants of concern (VOCs), and toward the antigenically variable receptor binding domain (RBD). A large proportion of RBD-directed neutralizing antibodies isolated from BA.1 breakthrough infection donors displayed convergent sequence features and broadly recognized SARS-CoV-2 VOCs. Together, these findings provide insights into the role of preexisting immunity in shaping the B cell response to heterologous SARS-CoV-2 variant exposure.


Subject(s)
B-Lymphocytes , COVID-19 , Immunologic Memory , Antibodies, Viral , B-Lymphocytes/immunology , COVID-19/immunology , COVID-19 Vaccines/immunology , Cross Reactions , Humans , Membrane Glycoproteins , SARS-CoV-2 , Spike Glycoprotein, Coronavirus/genetics , Viral Envelope Proteins
4.
J Biomol Tech ; 31(3): 100-111, 2020 09.
Article in English | MEDLINE | ID: mdl-32982601

ABSTRACT

Cell sorting is a commonly used technology to isolate highly purified cell populations for downstream applications. Because the sorted cells are destined for further analysis, i.e., gene expression assays or functional assays, ensuring that the sorting process itself has little effect on the cells is of utmost importance. Previous studies examining the effects of sorting on cellular function have primarily focused on a specific cell type or condition. One of the goals of the Flow Cytometry Research Group of the Association of Biomolecular Resource Facilities is to establish best practice guidelines for cell sorting conditions that minimize cell stress, perturbation, or injury to the sorted cell population. In this study, the effects of nozzle size, sample pressure, UV exposure, and instrument type were evaluated for their effects on gene expression and cell cycle using both established cell lines and primary cells across several flow cytometry shared facilities. Results indicate that nozzle size and pressure, as well as UV exposure and instrument type, have only minor effects on gene expression, which were diminished by subsequent culturing of the sorted cells. In this assessment, these data demonstrate that cell sorting itself, regardless of instrumentation used, has minimal effects on downstream cellular applications.


Subject(s)
Flow Cytometry , Gene Expression , Animals , B-Lymphocytes/metabolism , B-Lymphocytes/radiation effects , Cell Cycle , Cell Survival , Humans , Jurkat Cells , Mice , Mice, Inbred C57BL , Microarray Analysis , Mouse Embryonic Stem Cells/cytology , Mouse Embryonic Stem Cells/metabolism , Transcriptome/genetics , Ultraviolet Rays
5.
J Biomol Tech ; 2020 Jun 22.
Article in English | MEDLINE | ID: mdl-32831654

ABSTRACT

Cell sorting is a commonly used technology to isolate highly purified cell populations for downstream applications. Because the sorted cells are destined for further analysis, i.e., gene expression assays or functional assays, ensuring that the sorting process itself has little effect on the cells is of utmost importance. Previous studies examining the effects of sorting on cellular function have primarily focused on a specific cell type or condition. One of the goals of the Flow Cytometry Research Group of the Association of Biomolecular Resource Facilities is to establish best practice guidelines for cell sorting conditions that minimize cell stress, perturbation, or injury to the sorted cell population. In this study, the effects of nozzle size, sample pressure, UV exposure, and instrument type were evaluated for their effects on gene expression and cell cycle using both established cell lines and primary cells across several flow cytometry shared facilities. Results indicate that nozzle size and pressure, as well as UV exposure and instrument type, have only minor effects on gene expression, which were diminished by subsequent culturing of the sorted cells. In this assessment, these data demonstrate that cell sorting itself, regardless of instrumentation used, has minimal effects on downstream cellular applications.

6.
J Biol Chem ; 283(37): 25606-25616, 2008 Sep 12.
Article in English | MEDLINE | ID: mdl-18640985

ABSTRACT

We report a role for CA repeats in the 3'-untranslated region (3'-UTR) in regulating CD154 expression. Human CD154 is encoded by an unstable mRNA; this instability is conferred in cis by a portion of its 3'-UTR that includes a polypyrimidine-rich region and CA dinucleotide repeat. We demonstrate similar instability activity with the murine CD154 3'-UTR. This instability element mapped solely to a conserved 100-base CU-rich region alone, which we call a CU-rich response element. Surprisingly, the CA dinucleotide-rich region also regulated reporter expression but at the level of translation. This activity was associated with poly(A) tail shortening and regulated by heterogeneous nuclear ribonucleoprotein L levels. We conclude that the CD154 3'-UTR contains dual cis-acting elements, one of which defines a novel function for exonic CA dinucleotide repeats. These findings suggest a mechanism for the association of 3'-UTR CA-rich response element polymorphisms with CD154 overexpression and the subsequent risk of autoimmune disease.


Subject(s)
CD40 Ligand/genetics , Gene Expression Regulation , RNA Processing, Post-Transcriptional , 3' Untranslated Regions , Animals , Autoimmune Diseases , Base Sequence , Cattle , Heterogeneous-Nuclear Ribonucleoprotein L/metabolism , Humans , Mice , Molecular Sequence Data , Poly A/metabolism , Polymorphism, Genetic , Repetitive Sequences, Nucleic Acid
SELECTION OF CITATIONS
SEARCH DETAIL
...