PURPOSE: Three-dimensional (3D) printed patient-specific instruments (PSI) have been introduced to increase precision and simplify surgical procedures. Initial results in femoral and tibial osteotomies are promising, but validation studies on 3D planning, manufacturing of patient-specific cutting blocks and 3D evaluation of the attained results are lacking. METHODS: In this study, patient-specific cutting blocks and spacers were designed, fabricated, and used to perform a high tibial osteotomy (HTO). After segmentation of CT data sets from 13 human tibiae, 3D digital planning of the HTO was performed with a medial opening of 8 mm. These 3D models were used to fabricate patient-specific cutting blocks and spacers. After the surgical procedure, accuracy was evaluated measuring 3D joint angles and surface deviations. RESULTS: The lowest mean deviation was found to be 0.57° (SD ± 0.27) for the MPTA. Medial and lateral tibial slope deviated from the 3D planning by an average of 0.98° (SD ± 0.53) and 1.26° (SD ± 0.79), respectively, while tibial torsion deviated by an average of 5.74° (SD ± 3.24). Color analysis of surface deviations showed excellent and good agreement in 7 tibiae. CONCLUSION: With 3D cutting blocks and spacers, the 3D planning of the HTO can be translated into reality with small deviations of the resulting joint angles. Within this study, the results of the individual steps are examined for errors and thus a critical evaluation of this new and promising method for performing patient-specific HTOs is presented.

2.
J Orthop Surg (Hong Kong) ; 30(2): 10225536221101699, 2022.
Article in English | MEDLINE | ID: mdl-35694778

ABSTRACT

Purpose: In medial open-wedge high tibial osteotomy (HTO) hinge axis and osteotomy plane influence the resulting anatomy, but accurate angular quantifications using 3D-planning-simulations are lacking. The objectives of this study were developing a standardized and validated 3D-planning method of an HTO and to perform several simulated realignments to explain unintended anatomy changes. Methods: The cutting direction of the main osteotomy was defined parallel to the medial tibial slope and the hinge axis 1.5 cm distal to the lateral plateau. For interobserver testing, this 3D planning was performed on 13 digital models of human tibiae by two observers. In addition, four different hinge axis positions and five differently inclined osteotomy planes each were simulated. The osteotomy direction ranged from medial 0°-30° anteromedial, while the tilt of the osteotomy plane compared to the tibial plateau was -10° to +10°. All anatomic angular changes were calculated using 3D analysis. Results: Multiple HTO plannings by two medical investigators using standardized procedures showed only minimal differences. In the 3D-simulation, each 10° rotation of the hinge axis resulted in a 1.7° significant increase in slope. Tilting the osteotomy plane by 10° resulted in significant torsional changes of 2°, in addition to minor but significant changes in the medial proximal tibial angle (MPTA). Conclusion: Standardized 3D-planning of the HTO can be performed with high reliability using two-observer planning. 3D-simulations suggest that control of the osteotomy plane is highly relevant to avoid unintended changes in the resulting anatomy, but this can be a helpful tool to modify specific angles in different pathologies in the HTO.


Subject(s)
Osteoarthritis, Knee , Tibia , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Osteotomy/methods , Prostheses and Implants , Reproducibility of Results , Rotation , Tibia/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...