Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Parkinsonism Relat Disord ; : 106082, 2024 Mar 02.
Article in English | MEDLINE | ID: mdl-38458834
2.
J Radiol Prot ; 29(3): 393-407, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19690354

ABSTRACT

The aim of this study was to measure patient and staff doses simultaneously for some complex x-ray examinations. Measurements of dose-area product (DAP) and entrance skin dose (ESD) were carried out in a sample of 107 adult patients who underwent different x-ray examinations such as double contrast barium enema (DCBE), single contrast barium enema (SCBE), barium swallow, endoscopic retrograde cholangiopancreatography (ERCP) and percutaneous transhepatic cholangiography (PTC), and various orthopaedic surgical procedures. Dose measurements were made separately for each projection, and DAP, thermoluminescent dosimetry (TLD), film dosimetry and tube output measurement techniques were used. Staff doses were measured simultaneously with patient doses for these examinations, with the exception of barium procedures. The measured mean DAP values were found to be 8.33, 90.24, 79.96 Gy cm(2) for barium swallow, SCBE and DCBE procedures with the fluoroscopy times of 3.1, 4.43 and 5.86 min, respectively. The calculated mean DAP was 26.33 Gy cm(2) for diagnostic and 89.76 Gy cm(2) therapeutic ERCP examinations with the average fluoroscopy times of 1.9 and 5.06 min respectively. Similarly, the calculated mean DAP was 97.53 Gy cm(2) with a corresponding fluoroscopy time of 6.1 min for PTC studies. The calculated mean entrance skin dose (ESD) was 172 mGy for the orthopaedic surgical studies. Maximum skin doses were measured as 324, 891, 1218, 750, 819 and 1397 mGy for barium swallow, SCBE, DCBE, ERCP, PTC and orthopaedic surgical procedures, respectively. The high number of radiographs taken during barium enema examinations, and the high x-ray outputs of the fluoroscopic units used in ERCP, were the main reasons for high doses, and some corrective actions were immediately taken.


Subject(s)
Body Burden , Medical Staff, Hospital/statistics & numerical data , Occupational Exposure/analysis , Patients/statistics & numerical data , Radiation Monitoring/statistics & numerical data , Radiography/statistics & numerical data , Humans , Radiation Protection/methods , Radiation Protection/statistics & numerical data , Turkey/epidemiology
3.
J Radiol Prot ; 29(3): 409-15, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19690355

ABSTRACT

Renal stones can be treated either by extracorporeal shock wave lithotripsy (ESWL) or percutaneous nephrolithotomy (PCNL). Increasing use of fluoroscopic exposure for access and to detect stone location during PCNL make the measurement of patient and staff doses important. The main objective of this work was to assess patient and urologist doses for the PCNL examination. We used the tube output technique for determination of patient doses (n = 20) and lithium fluoride thermoluminescent dosimeter (TLD) chips for urologist dose measurements. The TLD technique was also used for some patient dose measurements (n = 7) for comparison with the tube output technique. Mean entrance skin doses of 191 and 117 mGy were measured by the tube output technique for anterior-posterior (AP) and right anterior oblique (RAO) 30 degrees /left anterior oblique (LAO) 30 degrees projections, respectively. The mean urologist doses for eye, finger and collar were measured as 26, 33.5 and 48 microGy per procedure, respectively. The mean effective dose per procedure for the urologist was 12.7 microSv. None of the individual skin dose results approach deterministic levels.


Subject(s)
Body Burden , Nephrostomy, Percutaneous/statistics & numerical data , Occupational Exposure/analysis , Patients/statistics & numerical data , Physicians/statistics & numerical data , Radiation Monitoring/statistics & numerical data , Radiography, Interventional/statistics & numerical data , Urology/statistics & numerical data , Humans , Radiation Dosage , Radiation Protection/methods , Radiation Protection/statistics & numerical data , Turkey/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...