Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Bioelectromagnetics ; 37(3): 141-151, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26991689

ABSTRACT

Electric fields produced by advanced pulsed microwave transmitter technology now readily exceed the Institute of Electrical and Electronic Engineers (IEEE) C.95.1 peak E-field limit of 100 kV/m, highlighting a need for scientific validation of such a specific limit. Toward this goal, we exposed Jurkat Clone E-6 human lymphocyte preparations to 20 high peak power microwave (HPPM) pulses (120 ns duration) with a mean peak amplitude of 2.3 MV/m and standard deviation of 0.1 with the electric field at cells predicted to range from 0.46 to 2.7 MV/m, well in excess of current standard limit. We observed that membrane integrity and cell morphology remained unchanged 4 h after exposure and cell survival 24 h after exposure was not statistically different from sham exposure or control samples. Using flow cytometry to analyze membrane disruption and morphological changes per exposed cell, no changes were observed in HPPM-exposed samples. Current IEEE C95.1-2005 standards for pulsed radiofrequency exposure limits peak electric field to 100 kV/m for pulses shorter than 100 ms [IEEE (1995) PC95.1-Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic and Electromagnetic Fields, 0 Hz to 300 GHz, Institute of Electrical and Electronic Engineers: Piscataway, NJ, USA]. This may impose large exclusion zones that limit HPPM technology use. In this study, we offer evidence that maximum permissible exposure of 100 kV/m for peak electric field may be unnecessarily restrictive for HPPM devices. Bioelectromagnetics. 37:141-151, 2016. © 2016 Wiley Periodicals, Inc.

2.
Forensic Sci Med Pathol ; 9(3): 308-20, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23543463

ABSTRACT

In previous studies hematocrit has been consistently increased in an anesthetized animal model after exposures to TASER(®) conducted energy weapons (CEWs). In the present study we analyzed changes in blood cell counts and red blood cell membrane proteins following two 30-s applications of a TASER C2 device (which is designed for civilian use). Hematocrit increased significantly from 33.2 ± 2.4 (mean ± SD) to 42.8 ± 4.6 % immediately after CEW exposure of eleven pigs (Sus scrofa). Red blood cell count increased significantly from 6.10 ± 0.55 × 10(12)/L to 7.45 ± 0.94 × 10(12)/L, and mean corpuscular volume increased significantly from 54.5 ± 2.4 fl to 57.8 ± 2.6 fl. Mean corpuscular hemoglobin concentration decreased significantly from 20.5 ± 0.7 to 18.5 ± 0.6 mM. Thirty protein spots (from two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis, selected for detailed comparison) exhibited greater densities 30-min post-exposure compared with pre-exposure values. A greater number of echinocytes were observed following CEW exposure. On the basis of these results it appears that, during the strong muscle contractions produced by TASER CEWs, a specific population of red blood cells (RBCs) may be released from the spleen or other reservoirs within the body. The total time of CEW exposure in the present study was relatively long compared with exposures in common law-enforcement scenarios. Despite statistically significant changes in red blood cell counts (and other measures directly related to RBCs), the alterations were short-lived. The transient nature of the changes would be likely to counteract any potentially detrimental effects.


Subject(s)
Conducted Energy Weapon Injuries/blood , Electroshock/instrumentation , Erythrocyte Membrane/metabolism , Membrane Proteins/blood , Weapons , Animals , Conducted Energy Weapon Injuries/etiology , Conducted Energy Weapon Injuries/physiopathology , Electrophoresis, Gel, Two-Dimensional , Electroshock/adverse effects , Equipment Design , Erythrocyte Count , Hematocrit , Hemoglobins/metabolism , Male , Models, Animal , Muscle Contraction , Muscle, Skeletal/physiopathology , Pilot Projects , Proteomics/methods , Sus scrofa , Time Factors
3.
PLoS One ; 6(1): e15642, 2011 Jan 26.
Article in English | MEDLINE | ID: mdl-21390200

ABSTRACT

In this study, we determined the LD(50) (50% lethal dose) for cell death, and the ED(50) (50% of cell population staining positive) for propidium (Pr) iodide uptake, and phosphatidylserine (PS) externalization for several commonly studied cell lines (HeLa, Jurkat, U937, CHO-K1, and GH3) exposed to 10-ns electric pulses (EP). We found that the LD(50) varied substantially across the cell lines studied, increasing from 51 J/g for Jurkat to 1861 J/g for HeLa. PS externalized at doses equal or lower than that required for death in all cell lines ranging from 51 J/g in Jurkat, to 199 J/g in CHO-K1. Pr uptake occurred at doses lower than required for death in three of the cell lines: 656 J/g for CHO-K1, 634 J/g for HeLa, and 142 J/g for GH3. Both Jurkat and U937 had a LD(50) lower than the ED(50) for Pr uptake at 780 J/g and 1274 J/g, respectively. The mechanism responsible for these differences was explored by evaluating cell size, calcium concentration in the exposure medium, and effect of trypsin treatment prior to exposure. None of the studied parameters correlated with the observed results suggesting that cellular susceptibility to injury and death by 10-ns EP was largely determined by cell physiology. In contrast to previous studies, our findings suggest that permeabilization of internal membranes may not necessarily be responsible for cell death by 10-ns EP. Additionally, a mixture of Jurkat and HeLa cells was exposed to 10-ns EP at a dose of 280 J/g. Death was observed only in Jurkat cells suggesting that 10-ns EP may selectively kill cells within a heterogeneous tissue.


Subject(s)
Cell Membrane/metabolism , Electricity/adverse effects , Animals , Annexin A5/metabolism , CHO Cells , Calcium/pharmacology , Cell Death/drug effects , Cell Size/drug effects , Cell Survival/drug effects , Cricetinae , Cricetulus , Electric Stimulation , Extracellular Space/drug effects , Extracellular Space/metabolism , Flow Cytometry , Fluorescein-5-isothiocyanate/metabolism , HeLa Cells , Humans , Jurkat Cells , Light , Microscopy, Confocal , Microscopy, Fluorescence , Phosphatidylserines/metabolism , Rats , Scattering, Radiation , Time Factors , Trypsin/pharmacology
4.
Biochim Biophys Acta ; 1800(11): 1210-9, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20691249

ABSTRACT

BACKGROUND: Nanosecond electric pulses (EP) disrupt cell membrane and organelles and cause cell death in a manner different from the conventional irreversible electroporation. We explored the cytotoxic effect of 10-ns EP (quantitation, mechanisms, efficiency, and specificity) in comparison with 300-ns, 1.8- and 9-µs EP. METHODS: Effects in Jurkat and U937 cells were characterized by survival assays, DNA electrophoresis and flow cytometry. RESULTS: 10-ns EP caused apoptotic or necrotic death within 2-20 h. Survival (S, %) followed the absorbed dose (D, J/g) as: S=alphaD((-K)), where coefficients K and alpha determined the slope and the "shoulder" of the survival curve. K was similar in all groups, whereas alpha was cell type- and pulse duration-dependent. Long pulses caused immediate propidium uptake and phosphatidylserine (PS) externalization, whereas 10-ns pulses caused PS externalization only. CONCLUSIONS: 1.8- and 9-µs EP cause cell death efficiently and indiscriminately (LD50 1-3 J/g in both cell lines); 10-ns EP are less efficient, but very selective (LD50 50-80 J/g for Jurkat and 400-500 J/g for U937); 300-ns EP show intermediate effects. Shorter EP open propidium-impermeable, small membrane pores ("nanopores"), triggering different cell death mechanisms. GENERAL SIGNIFICANCE: Nanosecond EP can selectively target certain cells in medical applications like tumor ablation.


Subject(s)
Apoptosis/radiation effects , Cell Membrane Permeability/radiation effects , Cell Membrane/pathology , Cell Membrane/radiation effects , Electromagnetic Fields , Cell Membrane/metabolism , DNA Damage , Electroporation , Flow Cytometry , Humans , Jurkat Cells , Organelles/metabolism , Organelles/pathology , Organelles/radiation effects , Phosphatidylserines/metabolism , U937 Cells
SELECTION OF CITATIONS
SEARCH DETAIL
...