Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 76
Filter
1.
Brain ; 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38842726

ABSTRACT

4-repeat (4R) tauopathies are neurodegenerative diseases characterized by cerebral accumulation of 4R tau pathology. The most prominent 4R-tauopathies are progressive-supranuclear-palsy (PSP) and corticobasal-degeneration (CBD) characterized by subcortical tau accumulation and cortical neuronal dysfunction, as shown by PET-assessed hypoperfusion and glucose hypometabolism. Yet, there is a spatial mismatch between subcortical tau deposition patterns and cortical neuronal dysfunction, and it is unclear how these two pathological brain changes are interrelated. Here, we hypothesized that subcortical tau pathology induces remote neuronal dysfunction in functionally connected cortical regions to test a pathophysiological model that mechanistically links subcortical tau accumulation to cortical neuronal dysfunction in 4R tauopathies. We included 51 Aß-negative patients with clinically diagnosed PSP variants (n=26) or Corticobasal Syndrome (CBS; n=25) who underwent structural MRI and 18F-PI-2620 tau-PET. 18F-PI-2620 tau-PET was recorded using a dynamic one-stop-shop acquisition protocol, to determine an early 0.5-2.5 min post-tracer-injection perfusion window for assessing cortical neuronal dysfunction, as well as a 20-40 min post-tracer-injection window to determine 4R-tau load. Perfusion-PET (i.e. early-window) was assessed in 200 cortical regions, and tau-PET was assessed in 32 subcortical regions of established functional brain atlasses. We determined tau epicenters as subcortical regions with highest 18F-PI-2620 tau-PET signal and assessed the connectivity of tau epicenters to cortical ROIs using a resting-state fMRI-based functional connectivity template derived from 69 healthy elderly controls from the ADNI cohort. Using linear regression, we assessed whether i) higher subcortical tau-PET was associated with reduced cortical perfusion and ii) whether cortical perfusion reductions were observed preferentially in regions closely connected to subcortical tau epicenters. As hypothesized, higher subcortical tau-PET was associated with overall lower cortical perfusion, which remained consistent when controlling for cortical tau-PET. Using group-average and subject-level PET data, we found that the seed-based connectivity pattern of subcortical tau epicenters aligned with cortical perfusion patterns, where cortical regions that were more closely connected to the tau epicenter showed lower perfusion. Together, subcortical tau-accumulation is associated with remote perfusion reductions indicative of neuronal dysfunction in functionally connected cortical regions in 4R-tauopathies. This suggests that subcortical tau pathology may induce cortical dysfunction, which may contribute to clinical disease manifestation and clinical heterogeneity.

3.
Neurology ; 102(1): e207901, 2024 Jan 09.
Article in English | MEDLINE | ID: mdl-38165362

ABSTRACT

BACKGROUND AND OBJECTIVES: Corticobasal syndrome (CBS) with underlying 4-repeat tauopathy is a progressive neurodegenerative disease characterized by declining cognitive and motor functions. Biomarkers for assessing pathologic brain changes in CBS including tau-PET, 18 kDa translocator protein (TSPO)-PET, structural MRI, neurofilament light chain (NfL), or glial fibrillary acidic protein (GFAP) have recently been evaluated for differential diagnosis and disease staging, yet their association with disease trajectories remains unclear. Therefore, we performed a head-to-head comparison of neuroimaging (tau-PET, TSPO-PET, structural MRI) and plasma biomarkers (NfL, GFAP) as prognostic tools for longitudinal clinical trajectories in ß-amyloid (Aß)-negative CBS. METHODS: We included patients with clinically diagnosed Aß-negative CBS with clinical follow-up data who underwent baseline structural MRI and plasma-NfL analysis for assessing neurodegeneration, [18F]PI-2620-PET for assessing tau pathology, [18F]GE-180-PET for assessing microglia activation, and plasma-GFAP analysis for assessing astrocytosis. To quantify tau and microglia load, we assessed summary scores of whole-brain, cortical, and subcortical PET signal. For structural MRI analysis, we quantified subcortical and cortical gray matter volume. Plasma NfL and GFAP values were assessed using Simoa-based immunoassays. Symptom progression was determined using a battery of cognitive and motor tests (i.e., Progressive Supranuclear Palsy Rating Scale [PSPRS]). Using linear mixed models, we tested whether the assessed biomarkers at baseline were associated with faster symptom progression over time (i.e., time × biomarker interaction). RESULTS: Overall, 21 patients with Aß-negative CBS with ∼2-year clinical follow-up data were included. Patients with CBS with more widespread global tau-PET signal showed faster clinical progression (PSPRS: B/SE = 0.001/0.0005, p = 0.025), driven by cortical rather than subcortical tau-PET. By contrast, patients with higher global [18F]GE-180-PET readouts showed slower clinical progression (PSPRS: B/SE = -0.056/0.023, p = 0.019). No association was found between gray matter volume and clinical progression. Concerning fluid biomarkers, only higher plasma-NfL (PSPRS: B/SE = 0.176/0.046, p < 0.001) but not GFAP was associated with faster clinical deterioration. In a subsequent sensitivity analysis, we found that tau-PET, TSPO-PET, and plasma-NfL showed significant interaction effects with time on clinical trajectories when tested in the same model. DISCUSSION: [18F]PI-2620 tau-PET, [18F]GE-180 TSPO-PET, and plasma-NfL show prognostic potential for clinical progression in patients with Aß-negative CBS with probable 4-repeat tauopathy, which can be useful for clinical decision-making and stratifying patients in clinical trials.


Subject(s)
Corticobasal Degeneration , Neurodegenerative Diseases , Tauopathies , Humans , Intermediate Filaments , Amyloid beta-Peptides , Biomarkers , Disease Progression , Receptors, GABA
4.
J Proteome Res ; 23(1): 117-129, 2024 01 05.
Article in English | MEDLINE | ID: mdl-38015820

ABSTRACT

The foundation for integrating mass spectrometry (MS)-based proteomics into systems medicine is the development of standardized start-to-finish and fit-for-purpose workflows for clinical specimens. An essential step in this pursuit is to highlight the common ground in a diverse landscape of different sample preparation techniques and liquid chromatography-mass spectrometry (LC-MS) setups. With the aim to benchmark and improve the current best practices among the proteomics MS laboratories of the CLINSPECT-M consortium, we performed two consecutive round-robin studies with full freedom to operate in terms of sample preparation and MS measurements. The six study partners were provided with two clinically relevant sample matrices: plasma and cerebrospinal fluid (CSF). In the first round, each laboratory applied their current best practice protocol for the respective matrix. Based on the achieved results and following a transparent exchange of all lab-specific protocols within the consortium, each laboratory could advance their methods before measuring the same samples in the second acquisition round. Both time points are compared with respect to identifications (IDs), data completeness, and precision, as well as reproducibility. As a result, the individual performances of participating study centers were improved in the second measurement, emphasizing the effect and importance of the expert-driven exchange of best practices for direct practical improvements.


Subject(s)
Plasma , Tandem Mass Spectrometry , Tandem Mass Spectrometry/methods , Chromatography, Liquid/methods , Workflow , Reproducibility of Results , Plasma/chemistry
5.
Eur Heart J Acute Cardiovasc Care ; 13(2): 203-212, 2024 Feb 16.
Article in English | MEDLINE | ID: mdl-37875127

ABSTRACT

AIMS: Veno-arterial extracorporeal membrane oxygenation therapy (VA-ECMO) restores circulation and tissue oxygenation in cardiogenic shock (CS) patients, but can also lead to complications. This study aimed to quantify VA-ECMO complications and analyse their association with overall survival as well as favourable neurological outcome (cerebral performance categories 1 + 2). METHODS AND RESULTS: All-comer patients with CS treated with VA-ECMO were retrospectively enrolled from 16 centres in four countries (2005-2019). Neurological, bleeding, and ischaemic adverse events (AEs) were considered. From these, typical VA-ECMO complications were identified and analysed separately as device-related complications. n = 501. Overall, 118 were women (24%), median age was 56.0 years, median lactate was 8.1 mmol/L. Acute myocardial infarction caused CS in 289 patients (58%). Thirty-days mortality was 40% (198/501 patients). At least one device-related complication occurred in 252/486 (52%) patients, neurological AEs in 108/469 (23%), bleeding in 192/480 (40%), ischaemic AEs in 123/478 (26%). The 22% of patients with the most AEs accounted for 50% of all AEs. All types of AEs were associated with a worse prognosis. Aside from neurological ones, all AEs and device-related complications were more likely to occur in women; although prediction of AEs outside of neurological AEs was generally poor. CONCLUSION: Therapy and device-related complications occur in half of all patients treated with VA-ECMO and are associated with a worse prognosis. They accumulate in some patients, especially in women. Aside from neurological events, identification of patients at risk is difficult, highlighting the need to establish additional quantitative markers of complication risk to guide VA-ECMO treatment in CS.


Subject(s)
Extracorporeal Membrane Oxygenation , Myocardial Infarction , Humans , Female , Middle Aged , Male , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Extracorporeal Membrane Oxygenation/methods , Retrospective Studies , Hospital Mortality
6.
Eur Heart J Suppl ; 25(Suppl I): I32-I38, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38093771

ABSTRACT

Cardiogenic shock (CS) is a life-threatening condition characterized by a state of inadequate systemic tissue perfusion caused by cardiac dysfunction. When to implement, change, or remove the use of a temporary mechanical circulatory support (tMCS) in patients with CS is dependent on the aetiology and severity. Here, patient scenarios underlying the need to escalate, de-escalate, wean, or bridge from tMCS devices are taken into consideration by interdisciplinary heart failure and CS teams. This includes a comprehensive review of and focus on the rationale for specific device escalation and de-escalation strategies, device selection, and general management.

8.
Article in English | MEDLINE | ID: mdl-37689237

ABSTRACT

OBJECTIVES: The Durable Mechanical Circulatory Support System After Extracorporeal Life Support registry is a multicenter registry of patients who were bridged from extracorporeal life support to a durable mechanical circulatory support system. Although numerous studies have highlighted the favorable outcomes after implantation of the HeartMate 3 (Abbott), the objective of our study is to examine the outcomes of patients who received HeartMate 3 support after extracorporeal life support. METHODS: Data of patients undergoing HeartMate 3 implantation from January 2016 to April 2022 at 14 centers were collected and evaluated. Inclusion criteria were patients with extracorporeal life support before HeartMate 3 implantation. The outcome was reported and compared with patients receiving other types of pumps. RESULTS: A total of 337 patients were bridged to durable mechanical circulatory support system after extracorporeal life support in the study period. Of those patients, 140 were supported with the HeartMate 3. The other types of pumps included 170 HeartWare HVADs (Medtronic) (86%), 14 HeartMate II devices (7%), and 13 (7%) other pumps (7%). Major postoperative complications included right heart failure requiring temporary right ventricular assist device in 60 patients (47%). Significantly lower postoperative stroke (16% vs 28%, P = .01) and pump thrombosis (3% vs 8%, P = .02) rates were observed in the patients receiving the HeartMate 3. The 30-day, 1-year, and 3-year survivals in patients receiving the HeartMate 3 were 87%, 73%, and 65%, respectively. CONCLUSIONS: In this critically ill patient population, the survivals of patients who were transitioned to the HeartMate 3 are deemed acceptable and superior to those observed when extracorporeal life support was bridged to other types of durable mechanical circulatory support systems.

9.
Eur Heart J Case Rep ; 7(7): ytad293, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37457054

ABSTRACT

Background: In patients with cardiogenic shock the clinical treatment often involves temporary mechanical circulatory support for initial haemodynamic stabilization to enable further assessment of therapeutic strategies. The surgically implanted Impella 5.5 can be used for several indications like ventricular unloading, haemodynamic support during high-risk interventions, and as a bridge-to-transplant strategy.We present an interdisciplinary managed case of using Impella 5.5 for multiple indications and treatment strategies in one patient. Case summary: A 66-year-old patient with known dilated cardiomyopathy was admitted with non-ST-elevation myocardial infarction and underwent urgent coronary bypass grafting. His native heart function did not recover and he experienced recurrent episodes of sustained ventricular tachycardia (VT) and electrical storm. He was evaluated for heart transplantation (OHT) and received a VT-ablation. However, he suffered an in-hospital cardiac arrest (IHCA) with subsequent implantation of an extracorporeal life support system (ECLS). After surgical placement of an Impella 5.5 due to left ventricular distension and pulmonary congestion, the ECLS was successfully weaned. He showed good neurological outcomes and underwent another high-risk VT-ablation. The patient was further stabilized under Impella 5.5 support in a bridge-to-transplant strategy. After 34 days he underwent a successful OHT. Discussion: In this interdisciplinary case report the surgically implanted Impella 5.5 as temporary mechanical circulatory support was used for multiple different indications and treatment strategies like ventricular unloading, haemodynamic support during high-risk interventions, and as bridge-to-transplant strategy in one patient.

10.
Front Cardiovasc Med ; 10: 1158248, 2023.
Article in English | MEDLINE | ID: mdl-37332585

ABSTRACT

Objectives: Implantation of implantable cardioverter defibrillators (ICD) reduces the risk of all-cause mortality in symptomatic heart failure (HF) patients with severe left ventricular (LV) dysfunction. Nevertheless, the prognostic impact of ICD therapy in continuous flow left ventricular assist device (LVAD) recipients remains controversial. Methods: 162 consecutive HF patients, who underwent LVAD implantation at our institution between 2010 and 2019, were categorized according to the presence (n = 94, ICD-group) or absence (n = 68, Control-group) of ICDs. Apart from clinical baseline and follow-up parameters, adverse events (AEs) related to ICD therapy and overall survival rates were retrospectively analyzed. Results: Out of 162 consecutive LVAD recipients 79 patients (48.8%) were preoperatively categorized as Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile ≤2. The prevalence of severe HF symptoms and preoperative use of short-term circulatory support devices (54.4% vs. 13.8%, p < 0.001) was higher within the Control-group, although baseline severity of LV and RV dysfunction was similar. Apart from an increased prevalence of perioperative right heart failure (RHF) within the Control-group (45.6% vs. 17.0%; p < 0.001), procedural characteristics and perioperative outcome were similar. Overall-survival during a median follow-up of 14 (3.0-36.5) months was similar within both groups (p = 0.46). During the first 2 years after LVAD implantation 53 ICD-related AEs occurred within the ICD-group. Thereof, lead-dysfunction occurred in 19 patients and unplanned ICD-reintervention in 11 patients. Furthermore, in 18 patients appropriate shocks without loss of consciousness occurred, whereas inappropriate shocks occurred in 5 patients. Conclusion: ICD therapy in LVAD recipients was not associated with a survival benefit or reduced morbidity after LVAD implantation. Conservative ICD-programming seems to be justified to avoid ICD-related complications and "awake shocks" after LVAD implantation.

11.
ESC Heart Fail ; 10(4): 2596-2606, 2023 08.
Article in English | MEDLINE | ID: mdl-37339937

ABSTRACT

AIMS: Whether sex affects selection for and outcomes after heart transplantation (HTx) remains unclear. We aimed to show sex differences in pre-transplant characteristics and outcomes after HTx. METHODS AND RESULTS: From 1995 to 2019, 49 200 HTx recipients were prospectively enrolled in the Organ Procurement and Transplantation Network. Logistic regression models were used to evaluate clinical characteristics by sex. Multivariable Cox regression models were fitted to assess sex differences in all-cause mortality, cardiovascular mortality, graft failure, cardiac allograft vasculopathy (CAV), and malignancy. In 49 200 patients (median age 55 years, interquartile range 46-62; 24.6% women), 49 732 events occurred during a median follow-up of 8.1 years. Men were older than women, had more often ischaemic cardiomyopathy (odds ratio [OR] 3.26, 95% confidence interval [CI] 3.11-3.42; P < 0.001), and a higher burden of cardiovascular risk factors, whereas women had less malignancies (OR 0.47, CI 0.44-0.51; P < 0.001). Men were more often treated in intensive care unit (OR 1.24, CI 1.12-1.37; P < 0.001) with a higher need for ventilatory (OR 1.24, CI 1.17-1.32; P < 0.001) or VAD (OR 1.53, CI 1.45-1.63; P < 0.001) support. After multivariable adjustment, men had a higher risk for CAV (hazard ratio [HR] 1.21, CI 1.13-1.29; P < 0.001) and malignancy (HR 1.80, CI 1.62-2.00; P < 0.001). There were no differences in all-cause mortality, cardiovascular mortality, and graft failure between sexes. CONCLUSIONS: In this US transplant registry, men and women differed in pre-transplant characteristics. Male sex was independently associated with incident CAV and malignancy even after multivariable adjustment. Our results underline the need for better personalized post-HTx management and care.


Subject(s)
Heart Diseases , Heart Transplantation , Humans , Male , Female , Middle Aged , Sex Characteristics , Retrospective Studies , Heart Transplantation/adverse effects , Proportional Hazards Models
13.
Artif Organs ; 47(6): 914-924, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37140177

ABSTRACT

Globalization in Asia and consequent strengthening of healthcare economic factors in tandem with an increasing heart failure (HF) population have enhanced potential for development and progress in the fields of HF medicine and mechanical circulatory support (MCS). In Japan, there are unique opportunities to investigate the outcome of acute and chronic MCS and a national registry for percutaneous and implantable left ventricular assist device (LVAD) including Impella pumps has been established. A Peripheral extracorporeal membrane oxygenation (ECMO) for acute MCS has been used in more than 7000 patients annually and Impella usage in more than 4000 patients over the past 4 years was noted. Recently, a novel centrifugal pump with hydrodynamically levitated impeller was developed and approved for mid-term extracorporeal circulatory support. In terms of chronic MCS more than 1200 continuous flow LVADs have been implanted during the past decade, and 2-year survival rate after primary LVAD implantation is 91%. Because of donor organ shortage, more than 70% of heart transplant recipients required LVAD support for more than 3 years and prevention and treatment of complications during long-term LVAD support have become important. Five important topics including hemocompatibility-related complications, LVAD infections, aortic valve insufficiency, right ventricular failure and cardiac recovery during LVAD support are discussed in this review for improving clinical outcomes. Findings from Japan will continue to provide useful information regarding MCS for the Asia-Pacific region and beyond.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Failure , Heart Transplantation , Heart-Assist Devices , Humans , Adult , Japan/epidemiology , Heart Failure/surgery , Heart Failure/complications , Heart-Assist Devices/adverse effects , Treatment Outcome
14.
EBioMedicine ; 89: 104456, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36745974

ABSTRACT

A major evolution from purely clinical diagnoses to biomarker supported clinical diagnosing has been occurring over the past years in neurology. High-throughput methods, such as next-generation sequencing and mass spectrometry-based proteomics along with improved neuroimaging methods, are accelerating this development. This calls for a consensus framework that is broadly applicable and provides a spot-on overview of the clinical validity of novel biomarkers. We propose a harmonized terminology and a uniform concept that stratifies biomarkers according to clinical context of use and evidence levels, adapted from existing frameworks in oncology with a strong focus on (epi)genetic markers and treatment context. We demonstrate that this framework allows for a consistent assessment of clinical validity across disease entities and that sufficient evidence for many clinical applications of protein biomarkers is lacking. Our framework may help to identify promising biomarker candidates and classify their applications by clinical context, aiming for routine clinical use of (protein) biomarkers in neurology.


Subject(s)
Nervous System Diseases , Humans , Biomarkers , Proteomics/methods , Mass Spectrometry , Neuroimaging
15.
Transpl Int ; 36: 10883, 2023.
Article in English | MEDLINE | ID: mdl-36814697

ABSTRACT

Among heart transplant (HT) recipients, a reduced immunological response to SARS-CoV-2 vaccination has been reported. We aimed to assess the humoral and T-cell response to SARS-CoV-2 vaccination in HT recipients to understand determinants of immunogenicity. HT recipients were prospectively enrolled from January 2021 until March 2022. Anti-SARS-CoV-2-Spike IgG levels were quantified after two and three doses of a SARS-CoV-2 vaccine (BNT162b2, mRNA1273, or AZD1222). Spike-specific T-cell responses were assessed using flow cytometry. Ninety-one patients were included in the study (69% male, median age 55 years, median time from HT to first vaccination 6.1 years). Seroconversion rates were 34% after two and 63% after three doses. Older patient age (p = 0.003) and shorter time since HT (p = 0.001) were associated with lower antibody concentrations after three vaccinations. There were no associations between vaccine types or immunosuppressive regimens and humoral response, except for prednisolone, which was predictive of a reduced response after two (p = 0.001), but not after three doses (p = 0.434). A T-cell response was observed in 50% after two and in 74% after three doses. Despite three vaccine doses, a large proportion of HT recipients exhibits a reduced immune response. Additional strategies are desirable to improve vaccine immunogenicity in this vulnerable group of patients.


Subject(s)
COVID-19 , Heart Transplantation , Humans , Male , Middle Aged , Female , COVID-19 Vaccines , BNT162 Vaccine , ChAdOx1 nCoV-19 , SARS-CoV-2 , Vaccination , Antibodies, Viral , Immunoglobulin G , Transplant Recipients
18.
Article in English | MEDLINE | ID: mdl-36216331

ABSTRACT

BACKGROUND: Systemic inflammation due to cardiogenic shock is associated with vasoplegia leading to organ hypoperfusion, right heart failure, and poor clinical outcome. Extracorporeal cytokine hemoadsorption emerged to attenuate excessive levels of inflammatory cytokines, potentially improving patient outcomes. Nevertheless, its prognostic impact during high-risk left ventricular assist device (LVAD) implantation remains unknown. METHODS: In total, 40 consecutive patients with advanced heart failure underwent continuous-flow LVAD implantation at our institution between 2018 and 2020. Out of 25 high-risk patients in cardiogenic shock (Interagency Registry for Mechanically Assisted Circulatory Support profile 1 and 2), 9 patients (CytoSorb group) underwent LVAD implantation with and 16 patients (control group) without simultaneous cytokine hemoadsorption during cardiopulmonary bypass. Besides preoperative patient characteristics, postoperative lactate clearance, vasopressor administration and mean arterial pressure, perioperative complication, and 30-day mortality rates were retrospectively analyzed. RESULTS: Apart from an increased rate of reoperations within the CytoSorb group, baseline characteristics including the severity of ventricular dysfunction and consecutive signs of end-organ failure were similar in both groups. Preoperative short-term mechanical circulatory support bridging was comparable (66.7 vs. 75%; p = 0.66) prior to LVAD implantation. Procedural characteristics including intraoperative volume management and postoperative vasopressor administration were similar in both groups. There was no difference regarding postoperative lactate clearance, although postoperative mean arterial pressure was significantly higher in the control group (71.3 vs. 57.4 mm Hg; p < 0.01). Furthermore, the 30-day mortality rate was significantly higher in the CytoSorb group (33.3 vs. 0.0%; p = 0.01). CONCLUSION: Extracorporeal cytokine hemoadsorption during high-risk LVAD implantation was not associated with a decrease of postoperative vasopressor support, improved hemodynamics, or an accelerated lactate clearance.

20.
Thorac Cardiovasc Surg ; 70(6): 458-466, 2022 09.
Article in English | MEDLINE | ID: mdl-35817063

ABSTRACT

OBJECTIVES: Cardiac support systems are being used increasingly more due to the growing prevalence of heart failure and cardiogenic shock. Reducing cardiac afterload, intracardiac pressure, and flow support are important factors. Extracorporeal membrane oxygenation (ECMO) and intracardiac microaxial pump systems (Impella) as non-permanent MCS (mechanical circulatory support) are being used increasingly. METHODS: We reviewed the recent literature and developed an international European registry for non-permanent MCS. RESULTS: Life-threatening conditions that are observed preoperatively often include reduced left ventricular function, systemic hypoperfusion, myocardial infarction, acute and chronic heart failure, myocarditis, and valve vitia. Postoperative complications that are commonly observed include severe systemic inflammatory response, ischemia-reperfusion injury, trauma-related disorders, which ultimately may lead to low cardiac output (CO) syndrome and organ dysfunctions, which necessitates a prolonged ICU stay. Choosing the appropriate device for support is critical. The management strategies and complications differ by system. The "heart-team" approach is inevitably needed.However despite previous efforts to elucidate these topics, it remains largely unclear which patients benefit from certain systems, when is the right time to initiate (MCS), which support system is appropriate, what is the optimal level and type of support, which therapeutic additive and supportive strategies should be considered and ultimately, what are the future prospects and therapeutic developments. CONCLUSION: The European cardiac surgical register ImCarS has been established as an IIT with the overall aim to evaluate data received from the daily clinical practice in cardiac surgery. Interested colleagues are cordially invited to join the register. CLINICAL REGISTRATION NUMBER: DRKS00024560. POSITIVE ETHICS VOTE: AZ 246/20 Faculty of Medicine, Justus-Liebig-University-Gießen.


Subject(s)
Cardiac Surgical Procedures , Heart Failure , Heart-Assist Devices , Cardiac Surgical Procedures/adverse effects , Heart Failure/diagnosis , Heart Failure/therapy , Heart-Assist Devices/adverse effects , Humans , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Treatment Outcome
SELECTION OF CITATIONS