Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Z Orthop Unfall ; 2023 Sep 06.
Article in English, German | MEDLINE | ID: mdl-37673084

ABSTRACT

Tibial plateau fractures are mostly complex and surgically demanding joint fractures, which require a comprehensive understanding of the fracture morphology, ligamentous and neurovascular injuries, as well as the diagnostic and therapeutic options for an optimal clinical outcome. Therefore, a standardised and structured approach is required. The success of the treatment of tibial plateau fractures relies on the interdisciplinary cooperation between surgical and conservative physicians in an outpatient and inpatient setting, physical therapists, patients and service providers (health insurance companies, statutory accident insurance, pension providers). On behalf of the German Society for Orthopaedics and Trauma Surgery (DGOU), the German Trauma Society (DGU) and the Society for Arthroscopy and Joint Surgery (AGA), under the leadership of the Fracture Committee of the German Knee Society (DKG), a guideline for tibial plateau fractures was created, which was developed in several voting rounds as part of a Delphi process. Based on the current literature, this guideline is intended to make clear recommendations and outline the most important treatment steps in diagnostics, therapy and follow-up treatment. Additionally, 25 statements were revised by the authors in several survey rounds using the Likert scale in order to reach a final consensus.

2.
Eur J Trauma Emerg Surg ; 49(6): 2561-2567, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37552339

ABSTRACT

AIMS: Visualization of the subtalar joint surface in surgical management of calcaneal factures remains a big challenge and anatomic reduction of the articular surface is essential for a good clinical outcome. We hypothesize that video-assistance can provide superior fracture reduction compared to fluoroscopy and that nanoscopy (NSC) achieves more extensive visualization compared to fracturoscopy (FSC). METHODS: Ten human cadaveric feet with artificially pre-fractured intraarticular calcaneal fractures with involvement of the posterior facet were treated via a minimal invasive subtalar approach. After initial control of reduction by 2D fluoroscopy, the reduction was further analyzed intraoperatively by FSC and NSC. 3D Scan served as gold standard control of reduction. Need of revision of reduction after the different visualization techniques was recorded and the extent of visualization of the subtalar joint surface in the medio-lateral dimension was compared for FSC and NSC. To quantify access and visualization of the medial and posterior facet, a depth gauge was used to measure from laterally at the clinically widest portion of the calcaneus targeted to the sustentaculum tali. The distance in millimetres was referred to the complete medio-lateral distance seen on paracoronal CT at the widest portion of the calcaneus. RESULTS: Fracture analysis in preoperative CT-scans according to Sanders classification revealed four type IC, two IIA, three IIC and one IIIAC fractures. Mean visualization of the medial and posterior facet was significantly improved with NSC (30.4 ± 3.78 mm) compared to FSC (23.6 ± 6.17 mm) (p = 0.008). An imperfect reduction requiring revision was more often required with NSC compared to FSC. Insufficient reduction using video-assistance was found in two cases. CONCLUSION: In order to optimize subtalar joint reduction and congruency, video-assisted techniques, especially NSC, provide superior visualization and thus can improve reduction in the surgical treatment of intraarticular calcaneal fractures.


Subject(s)
Ankle Injuries , Calcaneus , Fractures, Bone , Intra-Articular Fractures , Knee Injuries , Humans , Arthroscopy/methods , Fracture Fixation, Internal/methods , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Intra-Articular Fractures/diagnostic imaging , Intra-Articular Fractures/surgery , Calcaneus/diagnostic imaging , Calcaneus/surgery , Calcaneus/injuries , Cadaver , Treatment Outcome
3.
Diagnostics (Basel) ; 12(10)2022 Oct 20.
Article in English | MEDLINE | ID: mdl-36292236

ABSTRACT

(1) Background: In treating medial unicompartmental gonarthrosis, medial open wedge high tibial osteotomy (mOWHTO) reduces pain and is intended to delay a possible indication for joint replacement by relieving the affected compartment. This study aimed to investigate the influence of the osteotomy height with different hinge points in HTO in genu varum on the leg axis. (2) Methods: Fifty-five patients with varus lower leg alignment obtained full-weight bearing long-leg radiographs were analyzed. Different simulations were performed: Osteotomy height was selected at 3 and 4 cm distal to the tibial articular surface, and the hinge points were selected at 0.5 cm, 1 cm, and 1.5 cm medial to the fibular head, respectively. The target of each correction was 55% of the tibial plateau measured from the medial. Then, the width of the opening wedge was measured. Intraobserver and interobserver reliability were calculated. (3) Results: Statistically significant differences in wedge width were seen at an osteotomy height of 3 cm below the tibial plateau when the distance of the hinge from the fibular head was 0.5 cm to 1.5 cm (3 cm and 0.5 cm: 8.9 +/- 3.88 vs. 3 cm and 1.5 cm: 11.6 +/- 4.39 p = 0.012). Statistically significant differences were also found concerning the wedge width between the distances 0.5 to 1.5 cm from the fibular head at the osteotomy height of 4 cm below the tibial plateau. (4 cm and 0.5 cm: 9.0 +/- 3.76 vs. 4 cm and 1.5 cm: 11.4 +/- 4.27 p = 0.026). (4) Conclusion: A change of the lateral hinge position of 1 cm results in a change in wedge width of approximately 2 mm. If hinge positions are chosen differently in preoperative planning and intraoperatively, the result can lead to over- or under-correction.

SELECTION OF CITATIONS
SEARCH DETAIL
...