Results 1 - 20 de 25
Filter
1.
Sci Adv ; 9(42): eadj0540, 2023 10 20.
Article in English | MEDLINE | ID: mdl-37851816

ABSTRACT

The current cardiac pacemakers are battery dependent, and the pacing leads are prone to introduce valve damage and infection, plus a complete pacemaker retrieval is needed for battery replacement. Despite the reported wireless bioelectronics to pace the epicardium, open-chest surgery (thoracotomy) is required to implant the device, and the procedure is invasive, requiring prolonged wound healing and health care burden. We hereby demonstrate a fully biocompatible wireless microelectronics with a self-assembled design that can be rolled into a lightweight microtubular pacemaker for intravascular implantation and pacing. The radio frequency was used to transfer energy to the microtubular pacemaker for electrical stimulation. We show that this pacemaker provides effective pacing to restore cardiac contraction from a nonbeating heart and have the capacity to perform overdrive pacing to augment blood circulation in an anesthetized pig model. Thus, this microtubular pacemaker paves the way for the minimally invasive implantation of leadless and battery-free microelectronics.


Subject(s)
Cardiac Pacing, Artificial , Pacemaker, Artificial , Animals , Swine , Cardiac Pacing, Artificial/methods , Prostheses and Implants , Heart , Electric Stimulation , Equipment Design , Treatment Outcome
2.
Ann Biomed Eng ; 49(9): 2094-2102, 2021 Sep.
Article in English | MEDLINE | ID: mdl-33537925

ABSTRACT

Millions of patients worldwide are implanted with permanent pacemakers for the treatment of cardiac arrhythmias and conduction disorders. The increased use of these devices has established a growing clinical need to mitigate associated complications. Pacemaker leads, in particular, present the primary risks in most implants. While wireless power transfer holds great promise in eliminating implantable device leads, anatomical constraints limit efficient wireless transmission over the necessary operational range. We thereby developed a transmitter-centered control system for wireless power transfer with sufficient power for continuous cardiac pacing. Device safety was validated using a computational model of the system within an MRI-based anatomical model. The pacer was then fabricated to meet the acute constraints of the anterior cardiac vein (ACV) to enable intravascular deployment while maintaining power efficiency. Our computational model revealed the wireless system to operate at > 50 times below the tissue energy absorption safety criteria. We further demonstrated the capacity for ex vivo pacing of pig hearts at 60 beats per minute (BPM) and in vivo pacing at 120 BPM following pacer deployment in the ACV. This work thus established the capacity for wireless intravascular pacing with the potential to eliminate complications associated with current lead-based deep tissue implants.


Subject(s)
Cardiac Pacing, Artificial , Pacemaker, Artificial , Animals , Electric Power Supplies , Humans , Male , Models, Anatomic , Swine , Wireless Technology
4.
Sci Rep ; 7(1): 6180, 2017 07 21.
Article in English | MEDLINE | ID: mdl-28733677

ABSTRACT

Pacemakers have existed for decades as a means to restore cardiac electrical rhythms. However, lead-related complications have remained a clinical challenge. While market-released leadless devices have addressed some of the issues, their pacer-integrated batteries cause new health risks and functional limitations. Inductive power transfer enables wireless powering of bioelectronic devices; however, Specific Absorption Rate and size limitations reduce power efficiency for biomedical applications. We designed a remote-controlled system in which power requirements were significantly reduced via intermittent power transfer to control stimulation intervals. In parallel, the cardiac component was miniaturized to facilitate intravascular deployment into the anterior cardiac vein. Given size constraints, efficiency was optimal via a circular receiver coil wrapped into a half-cylinder with a meandering tail. The pacemaker was epicardially tested in a euthanized pig at 60 beats per minute, 2 V amplitude, and 1 ms pulse width, restoring mean arterial pressure from 0 to 37 mmHg. Power consumption was 1 mW at a range of > 3 cm with no misalignment and at 2 cm with 45° displacement misalignment, 45° x-axis angular misalignment, or 45° y-axis angular misalignment. Thus, we demonstrated a remote-controlled miniaturized pacing system with low power consumption, thereby providing a basis for the next generation of wireless implantable devices.


Subject(s)
Pacemaker, Artificial , Wireless Technology/instrumentation , Animals , Electric Power Supplies , Equipment Design , Humans , Miniaturization , Swine
5.
Chest ; 152(6): 1128-1134, 2017 12.
Article in English | MEDLINE | ID: mdl-28583617

ABSTRACT

BACKGROUND: Prostacyclins improve symptoms and survival in pulmonary arterial hypertension (PAH). In response to risks associated with external delivery systems, an implantable IV infusion system was developed. A multicenter, prospective, single-arm, clinical trial (DelIVery for PAH) was conducted to evaluate this system for treprostinil in PAH. This analysis describes the findings related to the implant procedure. METHODS: Patients (N = 64) with PAH (World Health Organization group 1) receiving stable IV treprostinil were enrolled. Patients were transitioned to a temporary peripheral IV infusion catheter prior to the procedure. System implantation was performed at 10 centers under general anesthesia or deep IV sedation by clinicians from various specialties. Central venous access was via the cephalic, subclavian, jugular, or axillary vein. Using an introducer and fluoroscopic guidance, the distal tip of the infusion catheter was placed at the superior caval-atrial junction. The catheter was tunneled from the venous access site to an abdominal subcutaneous pocket, where the pump was placed. RESULTS: Of the 64 patients enrolled, four exited prior to implantation. All 60 implant procedures were successful. At baseline, all patients were receiving treprostinil via an external pump at a mean dose of 71.4 ± 27.8 ng/kg/min (range: 22-142 ng/kg/min). The implant averaged 102 ± 32 min (range: 47-184 min). Clinically significant implant procedure-related complications included one pneumothorax, two infections, and one episode of atrial fibrillation. There were three postimplantation catheter dislocations in two patients. Common implant-related events that were not complications included implant site pain (83%) and bruising (17%). CONCLUSIONS: The procedure for inserting a fully implantable system for treprostinil was successfully performed, with few complications. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01321073; URL: www.clinicaltrials.gov.


Subject(s)
Catheterization, Central Venous/methods , Epoprostenol/analogs & derivatives , Hypertension, Pulmonary/drug therapy , Infusion Pumps, Implantable , Antihypertensive Agents/administration & dosage , Dose-Response Relationship, Drug , Epoprostenol/administration & dosage , Female , Follow-Up Studies , Humans , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/physiopathology , Infusions, Intravenous , Male , Middle Aged , Prospective Studies , Pulmonary Wedge Pressure/drug effects , Treatment Outcome
7.
Am J Cardiol ; 118(11): 1680-1684, 2016 Dec 01.
Article in English | MEDLINE | ID: mdl-27665206

ABSTRACT

Implanted cardiac arrhythmia devices can detect atrial tachyarrhythmias (atrial high-rate episodes [AHREs]) that are considered to correlate with atrial fibrillation and risk of stroke. In the IMPACT trial, oral anticoagulation was initiated when AHREs were detected by implanted cardioverter-defibrillators and withdrawn when they abated, according to a protocol accounting both for AHRE duration as detected by remote device monitoring and stroke risk assessment. In this analysis, we ascertained determinants of time in therapeutic range (TTR) among protocol-determined vitamin K antagonist-treated patients during the trial. We enrolled 2,718 patients with at least 1 additional stroke risk factor (CHADS2 score ≥1) at 104 arrhythmia centers. The sex, age <60, medical history, treatments interacting with VKA, tobacco use (2 points) and race (2 points for non-Caucasian) (SAMe-TT2R2) score is a simple clinical-derived score designed to aid decision-making on whether a patient is likely to achieve good anticoagulation control on vitamin K antagonist (e.g., warfarin), which was calculated and related to TTR achieved using the Rosendaal method. We analyzed 229 patients (mean age 66.7 years; mean CHADS2 score 2.85 [SD 1.1]) with mean TTR of 0.536 (SD 0.23) overall. Univariate analysis identified 5 variables associated with differences in mean TTR. Mean TTR was lower in those who were women (p = 0.031), of black race (p = 0.005) and in New York Heart Association class IV (p = 0.014), whereas hemoglobin >13.5 g/dl (p = 0.010) and New York Heart Association class I (p = 0.037) were associated with higher mean TTR. There was a significant difference in mean TTR value between US and non-US sites (Canada and Germany) (mean TTR for US: 0.513 vs non-US: 0.686; p <0.0001). Mean TTR was significantly lower (Δ = 0.1382, 95% CI 0.0382 to 0.2382) for patients with SAMe-TT2R2 scores of 4 (p = 0.007) and higher (Δ = 0.0612, 95% CI 0.0005 to 0.1219) for patients with SAMe-TT2R2 scores of 1 (p = 0.048). Linear regression confirmed a significant association between lower SAMe-TT2R2 score and improved anticoagulation control (p = 0.0021) with a 1-unit decrease in SAMe-TT2R2 score associated with an increase in TTR of 0.0404 (95% CI 0.0149 to 0.0659). In conclusion, clinical, geographical, and demographic factors were associated with the quality of anticoagulation control as reflected by TTR. Although overall TTR in this population was poor, lower SAMe-TT2R2 scores were associated with better TTR.


Subject(s)
Anticoagulants/administration & dosage , Atrial Fibrillation/complications , Defibrillators, Implantable , Risk Assessment , Stroke/prevention & control , Administration, Oral , Aged , Atrial Fibrillation/therapy , Blood Coagulation/drug effects , Dose-Response Relationship, Drug , Female , Humans , Male , Middle Aged , Risk Factors , Stroke/etiology , Treatment Outcome
8.
Am J Cardiol ; 117(4): 617-625, 2016 Feb 15.
Article in English | MEDLINE | ID: mdl-26832186

ABSTRACT

Expression of different cytokines and growth factors after myocardial injury has been associated with fibroplasia and dilatation versus reverse remodeling and myocardial repair. Specifically, the proinflammatory/fibrotic mediators: interleukin (IL)-6, epidermal growth factor, and fibroblast growth factor (FGF)-2 cause fibroplasia, whereas reparative cytokines including: IL-1α, IL-1ß, IL-4, and IL-13 can limit fibrosis. In appropriate patients, cardiac resynchronization therapy (CRT) reverses cardiomyopathy and improves outcome. However, a significant proportion will not respond to this therapy. We conducted this study to assess the association of proinflammatory/fibrotic and/or reparative immune response mediators at baseline with outcome after CRT. In the multicenter RISK study, plasma samples were collected prospectively before CRT implantation. Plasma IL-6, epidermal growth factor, FGF-2, IL-1α, IL-1ß, IL-4, and IL-13 were evaluated by Luminex technology. The primary outcome was predefined as freedom from heart failure hospitalization or death and a decrease in echocardiographic end-systolic volume of >15% at 12 months. To determine associations with the outcome, multivariate logistic regression models including baseline clinical characteristics and the specific cytokines and growth factors were constructed. On multivariate analysis of 257 patients, detectable reparative cytokine IL-13 was significantly associated with the primary outcome (odds ratio 3.79; 95% CI 2.10 to 6.82, p <0.0001). In contrast, detectable proinflammatory/fibrotic growth factor FGF-2 was negatively associated (odds ratio 0.31; 95% CI, 0.14 to 0.68; p = 0.004). In conclusion, in CRT recipients, baseline levels of inflammatory mediators affecting cardiac fibrosis versus repair were associated with subsequent clinical outcome.


Subject(s)
Cardiac Resynchronization Therapy/methods , Cytokines/blood , Heart Failure/blood , Inflammation/blood , Intercellular Signaling Peptides and Proteins/blood , Stroke Volume/physiology , Ventricular Remodeling/physiology , Aged , Biomarkers/blood , Echocardiography , Female , Follow-Up Studies , Heart Failure/physiopathology , Heart Failure/therapy , Humans , Male , Prognosis , Retrospective Studies , Time Factors , Treatment Outcome
9.
Eur Heart J ; 36(26): 1660-8, 2015 Jul 07.
Article in English | MEDLINE | ID: mdl-25908774

ABSTRACT

AIMS: Atrial tachyarrhythmias (ATs) detected by implanted devices are often atrial fibrillation or flutter (AF) associated with stroke. We hypothesized that introduction and termination of anticoagulation based upon AT monitoring would reduce both stroke and bleeding. METHODS AND RESULTS: We randomized 2718 patients with dual-chamber and biventricular defibrillators to start and stop anticoagulation based on remote rhythm monitoring vs. usual office-based follow-up with anticoagulation determined by standard clinical criteria. The primary analysis compared the composite endpoint of stroke, systemic embolism, and major bleeding with the two strategies. The trial was stopped after 2 years median follow-up based on futility of finding a difference in primary endpoints between groups. A total of 945 patients (34.8%) developed AT, 264 meeting study anticoagulation criteria. Adjudicated atrial electrograms confirmed AF in 91%; median time to initiate anticoagulation was 3 vs. 54 days in the intervention and control groups, respectively (P < 0.001). Primary events (2.4 vs. 2.3 per 100 patient-years) did not differ between groups (HR 1.06; 95% CI 0.75-1.51; P = 0.732). Major bleeding occurred at 1.6 vs. 1.2 per 100 patient-years (HR 1.39; 95% CI 0.89-2.17; P = 0.145). In patients with AT, thromboembolism rates were 1.0 vs. 1.6 per 100 patient-years (relative risk -35.3%; 95% CI -70.8 to 35.3%; P = 0.251). Although AT burden was associated with thromboembolism, there was no temporal relationship between AT and stroke. CONCLUSION: In patients with implanted defibrillators, the strategy of early initiation and interruption of anticoagulation based on remotely detected AT did not prevent thromboembolism and bleeding. CLINICAL TRIAL REGISTRATION: IMPACT ClinicalTrials.gov identifier: NCT00559988 ( http://clinicaltrials.gov/ct2/show/NCT00559988?term=NCT00559988&rank=1 ).


Subject(s)
Anticoagulants/therapeutic use , Atrial Fibrillation/therapy , Cardiac Resynchronization Therapy Devices , Defibrillators, Implantable , Aged , Female , Humans , Male , Middle Aged , Monitoring, Ambulatory/methods , Single-Blind Method , Stroke/prevention & control , Telemedicine/methods , Thromboembolism/prevention & control , Treatment Outcome , Wireless Technology
11.
Pacing Clin Electrophysiol ; 38(5): 581-90, 2015 May.
Article in English | MEDLINE | ID: mdl-25677851

ABSTRACT

BACKGROUND: We conducted a prospective multicenter study to assess the prognostic value of combined baseline preimplant plasma levels of the biomarkers cardiac troponin T (TnT) and B-type natriuretic peptide (BNP) among cardiac resynchronization therapy (CRT) with or without defibrillator capability (CRT-D) recipients. METHODS: At CRT-D implant, patients were stratified based on detectable TnT (≥0.01 ng/mL) and elevated BNP (predefined as >440 pg/mL) levels. Patients were classified into three groups: high (both detectable TnT and high BNP), intermediate (either detectable TnT or high BNP), or low (nondetectable TnT and low BNP). Patients were followed for 12 months. Survival curves free from mortality or heart failure hospitalizations (HFH) were assessed. To assess the predictive value of biomarker category, we constructed a multivariate Cox regression model, including the covariates of age, New York Heart Association class, left ventricular ejection fraction (LVEF), and QRS duration. RESULTS: A total of 267 patients (age 66 ± 12 years, males 80%, LVEF 25% ± 8%, ischemic cardiomyopathy 52%, QRSd 155 ± 26 ms) were studied. After 1 year, there were 13 deaths and 25 HFH events. A significant difference in event-free survival among the three groups was observed, with high and intermediate categories having worse survival than low (log-rank test, P < 0.001). In the multivariate model, risk category was a significant predictor of outcome: hazard ratios were 7.34 (95% confidence interval [CI]: 2.48-21.69) and 2.50 (95% confidence interval [CI]: 1.04-6.04) for high-risk and intermediate-risk groups, respectively (P < 0.0001). CONCLUSION: Among CRT-D recipients, baseline TnT and BNP values alone or in combination provide significant prognostic value for the outcome of mortality or HFH.


Subject(s)
Cardiac Resynchronization Therapy , Cardiomyopathies/therapy , Natriuretic Peptide, Brain/blood , Troponin/blood , Aged , Biomarkers/blood , Cardiomyopathies/physiopathology , Female , Humans , Male , Prospective Studies , Surveys and Questionnaires , Survival Analysis , Treatment Outcome
12.
Integr Biol (Camb) ; 6(8): 789-95, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24945366

ABSTRACT

Understanding the regenerative capacity of small vertebrate models has provided new insights into the plasticity of injured myocardium. Here, we demonstrate the application of flexible microelectrode arrays (MEAs) in elucidating electrophysiological phenotypes of zebrafish and neonatal mouse models of heart regeneration. The 4-electrode MEA membranes were designed to detect electrical signals in the aquatic environment. They were micro-fabricated to adhere to the non-planar body surface of zebrafish and neonatal mice. The acquired signals were processed to display an electrocardiogram (ECG) with high signal-to-noise-ratios, and were validated via the use of conventional micro-needle electrodes. The 4-channel MEA provided signal stability and spatial resolution, revealing the site-specific electrical injury currents such as ST-depression in response to ventricular cryo-injury. Thus, our polymer-based and wearable MEA membranes provided electrophysiological insights into long-term conduction phenotypes for small vertebral models of heart injury and regeneration with a translational implication for monitoring cardiac patients.


Subject(s)
Electrophysiology/instrumentation , Heart Injuries/pathology , Microelectrodes , Monitoring, Ambulatory/methods , Myocardium/pathology , Animals , Brain Injuries/pathology , Brain Injuries/physiopathology , Electrocardiography , Electroencephalography , Electrophysiological Phenomena , Equipment Design , Heart/physiology , Heart Conduction System/physiology , Heart Injuries/diagnosis , Mice , Phenotype , Polymers/chemistry , Regeneration , Seizures/pathology , Seizures/physiopathology , Signal-To-Noise Ratio , Zebrafish
14.
Chest ; 144(3): 959-965, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23598723

ABSTRACT

BACKGROUND: Heart rate (HR) and systolic BP (SBP) are significant multivariate predictors of survival in patients with pulmonary arterial hypertension (PAH) as part of a 19-element formula. To what extent HR and BP alone predict survival and future hospitalization in patients with PAH is unknown. METHODS: We analyzed data from the Registry to Evaluate Early and Long-term PAH Disease Management (REVEAL Registry), a prospective, observational study of patients with PAH. Patients were analyzed by quintile (Q) according to values of HR, SBP, and SBP/HR. Kaplan-Meier curves were calculated by Q for survival and freedom from hospitalization. RESULTS: For patients in the worst Q, 1-year survival after enrollment was 85% ± 2% for SBP, 86% ± 2% for HR, and 84% ± 2% for SBP/HR vs 91% ± 1% for the middle three Qs (P < .001). Hospitalization occurred more frequently than mortality but with a similar pattern among Qs. One-year survival after first follow-up of patients in the worst Q for change (Δ) in SBP since enrollment was 85% ± 2% (P = .004), 86% ± 2% for ΔHR (P = .12), and 84% ± 2% for ΔSBP/HR (P = .024) vs the middle three Qs (ΔSBP: 91% ± 1%; ΔHR: 90% ± 1%; ΔSBP/HR: 90% ± 1%). CONCLUSIONS: Changes in vital signs from enrollment to first follow-up were less predictive of mortality than the values of vital-sign parameters at either enrollment or first follow-up. HR, SBP, and SBP/HR at enrollment identified high-risk groups with survival differences of 5% to 7% and freedom from hospitalization differences of 9% to 11% vs lower-risk groups. SBP/HR defines the highest-risk group, including most of the high-risk patients defined by HR and SBP separately. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT00370214; URL: www.clinicaltrials.gov.


Subject(s)
Blood Pressure/physiology , Disease Management , Heart Rate/physiology , Hypertension, Pulmonary/physiopathology , Familial Primary Pulmonary Hypertension , Female , Follow-Up Studies , Hospitalization/statistics & numerical data , Humans , Hypertension, Pulmonary/mortality , Hypertension, Pulmonary/therapy , Male , Middle Aged , Prognosis , Prospective Studies , Survival Rate/trends , United States/epidemiology
15.
J Cardiovasc Electrophysiol ; 23(11): 1185-90, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22734591

ABSTRACT

BACKGROUND: Radiofrequency ablation is first-line therapy for atrial flutter (AFL). There are no studies of ablation in patients with severe pulmonary arterial hypertension (PAH). METHODS: Consecutive patients with severe PAH (systolic pulmonary artery pressure >60 mmHg) and AFL referred for ablation were evaluated. Patients with complex congenital heart disease were excluded. RESULTS: A total of 14 AFL ablation procedures were undertaken in 12 patients. A total of 75% of patients were female; mean age 49 ± 12 years. SPAP prior to ablation was 99 ± 35 mmHg. Baseline 6-minute walk distance was 295 ± 118 m. ECG demonstrated a typical AFL pattern in only 42% of cases. Baseline AFL cycle length was longer in PAH patients compared to controls (295 ± 53 ms vs 252 ± 35 ms, P = 0.006). Cavotricuspid isthmus dependence was verified in 86% of cases. Acute success was obtained in 86% of procedures. SPAP decreased from 114 ± 44 mmHg to 82 ± 38 mmHg after ablation (P = 0.004). BNP levels were lower postablation (787 ± 832 pg/mL vs 522 ± 745 pg/mL, P = 0.02). Complications were seen in 14%. A total of 80% (8/10) of patients were free of AFL at 3 months; 75% (6/8) at 1 year. CONCLUSION: Ablation of AFL in severe PAH patients is feasible, with good short- and intermediate-term success rates. The ECG pattern is not a reliable marker of isthmus dependence. The SPAP and BNP levels may decrease postablation. AFL may be a marker of poor outcomes in patients with PAH with a 1-year mortality rate of 42% in this study. This rate is higher than expected in the general PAH population.


Subject(s)
Atrial Flutter/surgery , Catheter Ablation , Hypertension, Pulmonary/complications , Adult , Aged , Arterial Pressure , Atrial Flutter/complications , Atrial Flutter/diagnosis , Atrial Flutter/physiopathology , Biomarkers/blood , Catheter Ablation/adverse effects , Chi-Square Distribution , Electrocardiography , Electrophysiologic Techniques, Cardiac , Exercise Test , Exercise Tolerance , Familial Primary Pulmonary Hypertension , Female , Humans , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/physiopathology , Kaplan-Meier Estimate , Male , Middle Aged , Natriuretic Peptide, Brain/blood , Predictive Value of Tests , Pulmonary Artery/physiopathology , Recurrence , Retrospective Studies , Severity of Illness Index , Time Factors , Treatment Outcome
17.
Europace ; 13(5): 683-8, 2011 May.
Article in English | MEDLINE | ID: mdl-21252192

ABSTRACT

BACKGROUND: The utility of defibrillation threshold testing in patients undergoing implantable cardioverter-defibrillator (ICD) implantation is controversial. Higher defibrillation thresholds have been noted in patients undergoing implantation of cardiac resynchronization therapy defibrillators (CRT-D). Since the risks and potential benefits of testing may be higher in this population, we sought to assess the impact of defibrillation safety margin or vulnerability safety margin testing in CRT-D recipients. METHODS AND RESULTS: A total of 256 consecutive subjects who underwent CRT-D implantation between January 2003 and December 2007 were retrospectively reviewed. Subjects were divided into two groups based on whether (n= 204) or not (n= 52) safety margin testing was performed. Patient characteristics, tachyarrhythmia therapies, procedural results, and clinical outcomes were recorded. Baseline characteristics, including heart failure (HF) severity, were comparable between the groups. Four cases of HF exacerbation (2%), including one leading to one death, were recorded in the tested group immediately post-implantation. No complications were observed in the untested group. After a mean follow-up of 32 ± 20 months, the proportion of appropriate shocks in the two groups was similar (31 vs. 25%, P = 0.49). There were three cases of failed appropriate shocks in the tested group, despite adequate safety margins at implantation, whereas no failed shocks were noted in the untested group. Survival was similar in the two groups. CONCLUSION: Defibrillation efficacy testing during implant of CRT-D was associated with increased morbidity and did not predict the success of future device therapy or improve survival during long-term follow-up.


Subject(s)
Cardiac Resynchronization Therapy/adverse effects , Defibrillators, Implantable/adverse effects , Diagnostic Techniques, Cardiovascular/adverse effects , Ventricular Fibrillation , Aged , Cardiac Resynchronization Therapy/statistics & numerical data , Defibrillators, Implantable/statistics & numerical data , Diagnostic Techniques, Cardiovascular/statistics & numerical data , Disease-Free Survival , Female , Follow-Up Studies , Heart Failure/epidemiology , Heart Failure/therapy , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Retrospective Studies , Risk Factors , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/therapy
18.
J Chem Inf Model ; 50(3): 327-38, 2010 Mar 22.
Article in English | MEDLINE | ID: mdl-20187659

ABSTRACT

To be able to estimate the reactivity of functional groups under certain reaction conditions, we have stored three types of data: (1) data of change or destruction of the functional groups by the conditions of the reaction conditions; (2) data showing no influence of the reaction conditions on the functional groups; and (3) data showing the relative reactivity of two functional groups in the presence of certain reaction conditions. These three types of data, considered together, form entities that are referenced as "interaction data". These interaction data are used in a synthesis design system called SYNSUP. A new module in our system has been constructed that automatically generates interaction data from the reaction databases. From 15 265 reactions in the database, our program selected 2763 useful reactions with yields of > or =90% and one functional group change. From these useful reactions, data regarding 465 interferences, 815 cases of inert functional groups (under the reaction conditions), and 62 relative rate data could be extracted. In addition, with the use of multiple relative rate datasets, the reactivity of more than two functional groups could be deduced.


Subject(s)
Databases, Factual , Organic Chemicals/chemical synthesis , Computer Simulation , Models, Chemical , Organic Chemicals/chemistry , Software
19.
Am Heart J ; 158(3): 364-370.e1, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19699858

ABSTRACT

Atrial fibrillation and atrial flutter are common cardiac arrhythmias associated with an increased risk of stroke in patients with additional risk factors. Anticoagulation ameliorates stroke risk, but because these arrhythmias may occur intermittently without symptoms, initiation of prophylactic therapy is often delayed until electrocardiographic documentation is obtained. The IMPACT study is a multicenter, randomized trial of remote surveillance technology in patients with implanted dual-chamber cardiac resynchronization therapy defibrillator (CRT-D) devices designed to test the hypothesis that initiation and withdrawal of oral anticoagulant therapy guided by continuous ambulatory monitoring of the atrial electrogram improve clinical outcomes by reducing the combined rate of stroke, systemic embolism, and major bleeding compared with conventional clinical management. For those in the intervention group, early detection of atrial high-rate episodes (AHRE) generates an automatic alert to initiate anticoagulation based on patient-specific stroke risk stratification. Subsequently, freedom from AHRE for predefined periods prompts withdrawal of anticoagulation to avoid bleeding. Patients in the control arm are managed conventionally, the anticoagulation decision prompted by incidental detection of atrial fibrillation or atrial flutter during routine clinical follow-up. The results will help define the clinical utility of wireless remote cardiac rhythm surveillance and help establish the critical threshold of AHRE burden warranting anticoagulant therapy in patients at risk of stroke. In this report, we describe the study design and baseline demographic and clinical features of the initial cohort (227 patients).


Subject(s)
Anticoagulants/therapeutic use , Atrial Fibrillation/therapy , Atrial Flutter/therapy , Cardiac Pacing, Artificial , Defibrillators, Implantable , Electrocardiography , Aged , Anticoagulants/adverse effects , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Flutter/complications , Atrial Flutter/diagnosis , Cohort Studies , Electrocardiography/methods , Embolism/etiology , Female , Hemorrhage/chemically induced , Humans , Male , Middle Aged , Research Design , Risk Assessment , Risk Factors , Stroke/etiology , Telemetry
20.
Pacing Clin Electrophysiol ; 32 Suppl 1: S194-7, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19250092

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) for primary prevention became standard of care after the publication of the second Multicenter Automatic Defibrillator Implantation Trial (MADIT-II) and Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT). OBJECTIVE: To determine the percentage of patients in a Veterans Affairs medical center appropriately referred for primary prophylaxis ICD and to further categorize the reasons patients are not being referred. METHODS: Echocardiograms obtained since the release of MADIT-II in 2002 were searched for a left ventricular ejection fraction (LVEF) < or = 35% and < or =30%. We randomly selected 120 patients per year from 2002 to 2006, for a total of 600 patients in each group. Data were reviewed to determine the number of ICD recipients and the reasons patients were not referred. RESULTS: In the LVEF < or = 35% group an ICD was implanted in 28% of 392 eligible patients. Nonreferral (58%) was the most common reason that eligible patients did not receive an ICD. Patients were not referred for ICD because of appropriate contraindications in 26% of cases. Overall mortality was 29% (15% with and 31% without ICD). In the LVEF < or =30% group an ICD was implanted in 33% of 388 eligible patients. Nonreferral (51%) was the most common reason that eligible patients did not receive an ICD. Patients were not referred for ICD because of appropriate contraindications in 24% of cases. Overall mortality was 28% (18% with and 32% without ICD). CONCLUSIONS: After the publication of MADIT-II and SCD-HeFT, only 42% of eligible patients with LVEF < or = 35% and 49% of patients with LVEF < or =30% were offered a potentially life-saving ICD between 2002 and 2006 in our medical center, sometimes with considerable delay.


Subject(s)
Defibrillators, Implantable/statistics & numerical data , Electric Countershock/mortality , Hospitals, Veterans/statistics & numerical data , Patient Selection , Referral and Consultation/statistics & numerical data , Ventricular Dysfunction, Left/mortality , Ventricular Dysfunction, Left/prevention & control , Aged , California/epidemiology , Electric Countershock/statistics & numerical data , Female , Humans , Male , Prevalence , Retrospective Studies , Survival Analysis , Survival Rate