Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Res Cardiol ; 101(4): 273-80, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22139127

ABSTRACT

BACKGROUND: Evaluation of left ventricular function (LV) is one of the most important tasks of echocardiography. Left ventricular longitudinal function has been recognized to differentiate myocardial disorders better than ejection fraction (EF) alone. But recent parameters are still dependent on image quality and time consuming. METHODS: Transthoracic echocardiography, tissue Doppler imaging, strain imaging and assessment of longitudinal function with a tissue motion annular displacement (TMAD) tracking algorithm were performed in 152 patients with various cardiac pathologies and 47 healthy volunteers in a clinical routine setting. RESULTS: Measures of longitudinal function such as LV peak systolic strain (SR, r² = 0.88, p < 0.001) and peak systolic strain rate (SRR, r² = 0.78, p < 0.001) correlated highly with TMAD. Tissue motion annular displacement was ultrafast and less time-consuming compared to strain imaging (8.2 ± 2.2 s, p < 0.001). Significantly more patients with reduced image quality could be analyzed compared to strain imaging (p < 0.001). The intra- and inter-observer variabilities were very low with 1.3 ± 1% and 1.7 ± 1.2%. Tissue motion annular displacement correlated well with clinical parameters (NYHA, r = -0.71, p < 0.001) as well as NT-proBNP (r = -0.73, p < 0.001) and identified patients with structural heart disease with a significantly higher sensitivity 92.1% and specificity 95.7% than did EF, SR, SRR or NT-proBNP (Cut-off:14.2%, p < 0.01). In a subgroup of patients with systemic light chain amyloidosis and preserved EF (>50%, n = 54), TMAD was significantly reduced, especially in those without any signs of cardiac involvement and was superior to other parameters of longitudinal function (p < 0.05). CONCLUSIONS: Tissue motion annular displacement is a rapid, sensitive and reproducible method for the assessment of LV longitudinal function, which is less dependent on image quality.


Subject(s)
Echocardiography, Doppler, Color/methods , Heart Diseases/physiopathology , Mitral Valve/diagnostic imaging , Ventricular Function, Left , Aged , Algorithms , Case-Control Studies , Humans , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Systole
SELECTION OF CITATIONS
SEARCH DETAIL
...