1.
Acta Ophthalmol (Copenh) ; 65(2): 244-50, 1987 Apr.
Article in English | MEDLINE | ID: mdl-3604617

ABSTRACT

The electronically foot-switch controlled irrigation/aspiration instruments have several disadvantages due to the big 'dead space' between the pump and the aspiration cannula. A new high precision fingertip controlled aspiration system is described. A specially designed ball valve connects the aspiration cannula directly to the vacuum reservoir, thereby almost eliminating the dead space. The system is nonelectric, it has no moving parts, it is easy to operate and highly cost efficient.


Subject(s)
Cataract Extraction/instrumentation , Suction/instrumentation , Cataract Extraction/methods , Humans , Suction/methods , Vacuum
3.
Acta Ophthalmol (Copenh) ; 55(2): 317-32, 1977 Apr.
Article in English | MEDLINE | ID: mdl-577103

ABSTRACT

The optical function of acrylic cylinders used in keratoprostheses is demonstrated by using a water-filled minicamera as a model of the aphakic human eye. Lengths and diameters of the optical cylinders are important factors influencing the visual fields. The dimensions to be chosen, depends on the thickness of the cornea and the supporting tissues. The most suitable combination of visual field, magnification and diameter of the retinal image field is obtained with optical cylinders with a concave posterior surface. Using a fixed radius of curvature of the posterior surface, the radius of the anterior surfaces are calculated to make the eye emmetropic. With such a cylinder of length 4.5 mm and diameter 2.1 mm a circular visual field of 48 degrees is obtained. With cylinder length 6.0 mm the visual field is at least 35 degrees. The retinal image is about 19% larger than that of the normal phakic eye. Cylinder length exceeding 6.0 mm require a greater diameter to provide an adequate visual field. With cylinder lengths up to 6.0 mm and diameters not less than 2.1 mm, the diameter of the retinal image field is at least 12.0 mm. Accidental obliquity of the optical cylinder or off-center implantation give the possibility of undesired projection of the image field outside the macula. The obliquity or degree of off-center implantation tolerance is calculated. The retinal image may be improved by darkening the side of the cylinder.


Subject(s)
Cornea/surgery , Prostheses and Implants , Evaluation Studies as Topic , Models, Biological , Vision Tests/instrumentation , Visual Fields