Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
ACS Cent Sci ; 10(5): 969-977, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38799658

ABSTRACT

Immunosuppressants are clinically approved drugs to treat the potential rejection of transplanted organs and require frequent monitoring due to their narrow therapeutic window. Immunophilins are small proteins that bind immunosuppressants with high affinity, yet there are no examples of fluorogenic immunophilins and their potential application as optical biosensors for immunosuppressive drugs in clinical biosamples. In the present work, we designed novel diazonium BODIPY salts for the site-specific labeling of tyrosine residues in peptides via solid-phase synthesis as well as for late-stage functionalization of whole recombinant proteins. After the optimization of a straightforward one-step labeling procedure for immunophilins PPIA and FKBP12, we demonstrated the application of a fluorogenic analogue of FKBP12 for the selective detection of the immunosuppressant drug tacrolimus, including experiments in urine samples from patients with functioning renal transplants. This chemical methodology opens new avenues to rationally design wash-free immunophilin-based biosensors for rapid therapeutic drug monitoring.

2.
Phys Med ; 120: 103334, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38520889

ABSTRACT

PURPOSE: Contrast-enhanced digital mammography (CEDM) is a relatively new imaging technique recombining low- and high-energy mammograms to emphasise iodine contrast. This work aims to perform a multicentric physical and dosimetric characterisation of four state-of-the-art CEDM systems. METHODS: We evaluated tube output, half-value-layer (HVL) for low- and high-energy and average glandular dose (AGD) in a wide range of equivalent breast thicknesses. CIRS phantom 022 was used to estimate the overall performance of a CEDM examination in the subtracted image in terms of the iodine difference signal (S). To calculate dosimetric impact of CEDM examination, we collected 4542 acquisitions on patients. RESULTS: Even if CEDM acquisition strategies differ, all the systems presented a linear behaviour between S and iodine concentration. The curve fit slopes expressed in PV/mg/cm2 were in the range [92-97] for Fujifilm, [31-32] for GE Healthcare, [35-36] for Hologic, and [114-130] for IMS. Dosimetric data from patients were matched with AGD values calculated using equivalent PMMA thicknesses. Fujifilm exhibited the lowest values, while GE Healthcare showed the highest. CONCLUSION: The subtracted image showed the ability of all the systems to give important information about the linearity of the signal with the iodine concentrations. All the patient-collected doses were under the AGD EUREF 2D Acceptable limit, except for patients with thicknesses ≤35 mm belonging to GE Healthcare and Hologic, which were slightly over. This work demonstrates the importance of testing each CEDM system to know how it performs regarding dose and the relationship between PV and iodine concentration.


Subject(s)
Breast Neoplasms , Iodine , Humans , Female , Radiographic Image Enhancement/methods , Contrast Media , Mammography/methods , Breast , Phantoms, Imaging
3.
Inflamm Res ; 73(4): 515-530, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38308760

ABSTRACT

OBJECTIVE AND DESIGN: We aimed to identify cytokines whose concentrations are related to lung damage, radiomic features, and clinical outcomes in COVID-19 patients. MATERIAL OR SUBJECTS: Two hundred twenty-six patients with SARS-CoV-2 infection and chest computed tomography (CT) images were enrolled. METHODS: CCL18, CHI3L1/YKL-40, GAL3, ANG2, IP-10, IL-10, TNFα, IL-6, soluble gp130, soluble IL-6R were quantified in plasma samples using Luminex assays. The Mann-Whitney U test, the Kruskal-Wallis test, correlation and regression analyses were performed. Mediation analyses were used to investigate the possible causal relationships between cytokines, lung damage, and outcomes. AVIEW lung cancer screening software, pyradiomics, and XGBoost classifier were used for radiomic feature analyses. RESULTS: CCL18, CHI3L1, and ANG2 systemic levels mainly reflected the extent of lung injury. Increased levels of every cytokine, but particularly of IL-6, were associated with the three outcomes: hospitalization, mechanical ventilation, and death. Soluble IL-6R showed a slight protective effect on death. The effect of age on COVID-19 outcomes was partially mediated by cytokine levels, while CT scores considerably mediated the effect of cytokine levels on outcomes. Radiomic-feature-based models confirmed the association between lung imaging characteristics and CCL18 and CHI3L1. CONCLUSION: Data suggest a causal link between cytokines (risk factor), lung damage (mediator), and COVID-19 outcomes.


Subject(s)
COVID-19 , Lung Neoplasms , Humans , Interleukin-6 , SARS-CoV-2 , Chitinase-3-Like Protein 1 , Early Detection of Cancer , Radiomics , Lung/diagnostic imaging , Cytokines , Chemokines, CC
4.
Eur J Cancer ; 199: 113553, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38262307

ABSTRACT

AIM: The analyses here reported aim to compare the screening performance of digital tomosynthesis (DBT) versus mammography (DM). METHODS: MAITA is a consortium of four Italian trials, REtomo, Proteus, Impeto, and MAITA trial. The trials adopted a two-arm randomised design comparing DBT plus DM (REtomo and Proteus) or synthetic-2D (Impeto and MAITA trial) versus DM; multiple vendors were included. Women aged 45 to 69 years were individually randomised to one round of DBT or DM. FINDINGS: From March 2014 to February 2022, 50,856 and 63,295 women were randomised to the DBT and DM arm, respectively. In the DBT arm, 6656 women were screened with DBT plus synthetic-2D. Recall was higher in the DBT arm (5·84% versus 4·96%), with differences between centres. With DBT, 0·8/1000 (95% CI 0·3 to 1·3) more women received surgical treatment for a benign lesion. The detection rate was 51% higher with DBT, ie. 2·6/1000 (95% CI 1·7 to 3·6) more cancers detected, with a similar relative increase for invasive cancers and ductal carcinoma in situ. The results were similar below and over the age of 50, at first and subsequent rounds, and with DBT plus DM and DBT plus synthetic-2D. No learning curve was appreciable. Detection of cancers >= 20 mm, with 2 or more positive lymph nodes, grade III, HER2-positive, or triple-negative was similar in the two arms. INTERPRETATION: Results from MAITA confirm that DBT is superior to DM for the detection of cancers, with a possible increase in recall rate. DBT performance in screening should be assessed locally while waiting for long-term follow-up results on the impact of advanced cancer incidence.


Subject(s)
Breast Neoplasms , Carcinoma, Intraductal, Noninfiltrating , Female , Humans , Breast/diagnostic imaging , Breast/pathology , Breast Neoplasms/diagnosis , Early Detection of Cancer/methods , Incidence , Mammography/methods , Mass Screening/methods , Middle Aged , Aged , Randomized Controlled Trials as Topic
5.
Diagnostics (Basel) ; 13(14)2023 Jul 23.
Article in English | MEDLINE | ID: mdl-37510195

ABSTRACT

Anterior segment optical coherence tomography (AS-OCT) allows the explore not only the anterior chamber but also the front part of the vitreous cavity. Our cross-sectional single-centre study investigated whether AS-OCT can distinguish between vitreous involvement due to vitreoretinal lymphoma (VRL) and vitritis in uveitis. We studied AS-OCT images from 28 patients (11 with biopsy-proven VRL and 17 with differential diagnosis uveitis) using publicly available radiomics software written in MATLAB. Patients were divided into two balanced groups: training and testing. Overall, 3260/3705 (88%) AS-OCT images met our defined quality criteria, making them eligible for analysis. We studied five different sets of grey-level samplings (16, 32, 64, 128, and 256 levels), finding that 128 grey levels performed the best. We selected the five most effective radiomic features ranked by the ability to predict the class (VRL or uveitis). We built a classification model using the xgboost python function; through our model, 87% of eyes were correctly diagnosed as VRL or uveitis, regardless of exam technique or lens status. Areas under the receiver operating characteristic curves (AUC) in the 128 grey-level model were 0.95 [CI 0.94, 0.96] and 0.84 for training and testing datasets, respectively. This preliminary retrospective study highlights how AS-OCT can support ophthalmologists when there is clinical suspicion of VRL.

6.
Bioconjug Chem ; 34(8): 1374-1379, 2023 08 16.
Article in English | MEDLINE | ID: mdl-37462264

ABSTRACT

The targeted delivery of bioactive proteins, such as cytokines, for cancer immunotherapy approaches mostly relies on antibodies or antibody fragments. However, fusion proteins may display low tissue penetration due to a large molecular size. Small molecule ligands with high affinity toward tumor-associated antigens provide a promising alternative for the selective delivery of cytokines to tumor lesions. We developed a one-pot procedure for the site-specific thiazolidine formation between an aldehyde bearing small molecule and the in situ generated N-terminal cysteine of a bioactive protein. Thereby, neoleukin-2/15 (Neo-2/15), a computationally engineered interleukin-2 and -15 mimic, was chemically conjugated to acetazolamide plus, a potent carbonic anhydrase IX (CAIX) ligand. The conjugate retained the biological activity of Neo-2/15 and revealed its ability to accumulate in renal cell carcinoma (SK-RC-52) xenografts upon systemic intravenous administration. The results highlight the potential of small molecule targeting moieties to drive the accumulation of a protein cargo to the respective disease site while conserving the small construct size.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Humans , Cytokines , Antigens, Neoplasm/metabolism , Carcinoma, Renal Cell/pathology , Acetazolamide/chemistry , Acetazolamide/metabolism , Cell Line, Tumor
7.
Chem Soc Rev ; 52(16): 5352-5372, 2023 Aug 14.
Article in English | MEDLINE | ID: mdl-37376918

ABSTRACT

T cells are an essential part of the immune system with crucial roles in adaptive response and the maintenance of tissue homeostasis. Depending on their microenvironment, T cells can be differentiated into multiple states with distinct functions. This myriad of cellular activities have prompted the development of numerous smart probes, ranging from small molecule fluorophores to nanoconstructs with variable molecular architectures and fluorescence emission mechanisms. In this Tutorial Review, we summarize recent efforts in the design, synthesis and application of smart probes for imaging T cells in tumors and inflammation sites by targeting metabolic and enzymatic biomarkers as well as specific surface receptors. Finally, we briefly review current strategies for how smart probes are employed to monitor the response of T cells to anti-cancer immunotherapies. We hope that this Review may help chemists, biologists and immunologists to design the next generation of molecular imaging probes for T cells and anti-cancer immunotherapies.


Subject(s)
Molecular Probes , T-Lymphocytes , T-Lymphocytes/metabolism , Fluorescent Dyes , Immunotherapy , Optical Imaging
8.
Eur J Radiol ; 163: 110812, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37068414

ABSTRACT

PURPOSE: To evaluated the accuracy of spectral parameters quantification of four different CT scanners in dual energy examinations of the lung using a dedicated phantom. METHOD: Measurements were made with different technologies of the same vendor: one dual source CT scanner (DSCT), one TwinBeam (i.e. split filter) and two sequential acquisition single source scanners (SSCT). Angular separation of Calcium and Iodine signals were calculated from scatter plots of low-kVp versus high-kVp HUs. Electron density (ρe), effective atomic number (Zeff) and Iodine concentration (Iconc) were measured using Syngo.via software. Accuracy (A) of ρe, Zeff and Iconc was evaluated as the absolute percentage difference (D%) between reference values and measured ones, while precision (P) was evaluated as the variability σ obtained by repeating the measurement with different acquisition/reconstruction settings. RESULTS: Angular separation was significantly larger for DSCT (α = 9.7°) and for sequential SSCT (α = 9.9°) systems. TwinBeam was less performing in material separation (α = 5.0°). The lowest average A was observed for TwinBeam (Aρe = [4.7 ± 1.0], AZ = [9.1 ± 3.1], AIconc = [19.4 ± 4.4]), while the best average A was obtained for Flash (Aρe = [1.8 ± 0.4], AZ = [3.5 ± 0.7], AIconc = [7.3 ± 1.8]). TwinBeam presented inferior average P (Pρe = [0.6 ± 0.1], PZ = [1.1 ± 0.2], PIconc = [10.9 ± 4.9]), while other technologies demonstrate a comparable average. CONCLUSIONS: Different technologies performed material separation and spectral parameter quantification with different degrees of accuracy and precision. DSCT performed better while TwinBeam demonstrated not excellent performance. Iodine concentration measurements exhibited high variability due to low Iodine absolute content in lung nodules, thus limiting its clinical usefulness in pulmonary applications.


Subject(s)
Iodine , Tomography, X-Ray Computed , Humans , Tomography Scanners, X-Ray Computed , Lung/diagnostic imaging , Software , Phantoms, Imaging
9.
Angew Chem Int Ed Engl ; 61(41): e202207508, 2022 10 10.
Article in English | MEDLINE | ID: mdl-35993914

ABSTRACT

Increased levels of tumor-associated macrophages (TAMs) are indicators of poor prognosis in most cancers. Although antibodies and small molecules blocking the recruitment of macrophages to tumors are under evaluation as anticancer therapies, these strategies are not specific for macrophage subpopulations. Herein we report the first enzyme-activatable chemokine conjugates for effective targeting of defined macrophage subsets in live tumors. Our constructs exploit the high expression of chemokine receptors (e.g., CCR2) and the activity of cysteine cathepsins in TAMs to target these cells selectively over other macrophages and immune cells (e.g., neutrophils, T cells, B cells). Furthermore, we demonstrate that cathepsin-activatable chemokines are compatible with both fluorescent and therapeutic cargos, opening new avenues in the design of targeted theranostic probes for immune cells in the tumor microenvironment.


Subject(s)
Cysteine , Tumor-Associated Macrophages , Cathepsins , Chemokines , Receptors, Chemokine , Tumor Microenvironment
10.
Curr Oncol ; 29(8): 5179-5194, 2022 07 22.
Article in English | MEDLINE | ID: mdl-35892979

ABSTRACT

The purpose of this multi-centric work was to investigate the relationship between radiomic features extracted from pre-treatment computed tomography (CT), positron emission tomography (PET) imaging, and clinical outcomes for stereotactic body radiation therapy (SBRT) in early-stage non-small cell lung cancer (NSCLC). One-hundred and seventeen patients who received SBRT for early-stage NSCLC were retrospectively identified from seven Italian centers. The tumor was identified on pre-treatment free-breathing CT and PET images, from which we extracted 3004 quantitative radiomic features. The primary outcome was 24-month progression-free-survival (PFS) based on cancer recurrence (local/non-local) following SBRT. A harmonization technique was proposed for CT features considering lesion and contralateral healthy lung tissues using the LASSO algorithm as a feature selector. Models with harmonized CT features (B models) demonstrated better performances compared to the ones using only original CT features (C models). A linear support vector machine (SVM) with harmonized CT and PET features (A1 model) showed an area under the curve (AUC) of 0.77 (0.63-0.85) for predicting the primary outcome in an external validation cohort. The addition of clinical features did not enhance the model performance. This study provided the basis for validating our novel CT data harmonization strategy, involving delta radiomics. The harmonized radiomic models demonstrated the capability to properly predict patient prognosis.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Radiosurgery , Carcinoma, Non-Small-Cell Lung/pathology , Humans , Lung Neoplasms/pathology , Neoplasm Recurrence, Local , Radiosurgery/methods , Retrospective Studies
11.
J Chem Theory Comput ; 18(8): 5068-5078, 2022 Aug 09.
Article in English | MEDLINE | ID: mdl-35837736

ABSTRACT

Existing computational methods for estimating pKa values in proteins rely on theoretical approximations and lengthy computations. In this work, we use a data set of 6 million theoretically determined pKa shifts to train deep learning models, which are shown to rival the physics-based predictors. These neural networks managed to infer the electrostatic contributions of different chemical groups and learned the importance of solvent exposure and close interactions, including hydrogen bonds. Although trained only using theoretical data, our pKAI+ model displayed the best accuracy in a test set of ∼750 experimental values. Inference times allow speedups of more than 1000× compared to physics-based methods. By combining speed, accuracy, and a reasonable understanding of the underlying physics, our models provide a game-changing solution for fast estimations of macroscopic pKa values from ensembles of microscopic values as well as for many downstream applications such as molecular docking and constant-pH molecular dynamics simulations.


Subject(s)
Deep Learning , Molecular Docking Simulation , Molecular Dynamics Simulation , Proteins/chemistry , Static Electricity
12.
Angew Chem Weinheim Bergstr Ger ; 134(41): e202207508, 2022 Oct 10.
Article in English | MEDLINE | ID: mdl-38505293

ABSTRACT

Increased levels of tumor-associated macrophages (TAMs) are indicators of poor prognosis in most cancers. Although antibodies and small molecules blocking the recruitment of macrophages to tumors are under evaluation as anticancer therapies, these strategies are not specific for macrophage subpopulations. Herein we report the first enzyme-activatable chemokine conjugates for effective targeting of defined macrophage subsets in live tumors. Our constructs exploit the high expression of chemokine receptors (e.g., CCR2) and the activity of cysteine cathepsins in TAMs to target these cells selectively over other macrophages and immune cells (e.g., neutrophils, T cells, B cells). Furthermore, we demonstrate that cathepsin-activatable chemokines are compatible with both fluorescent and therapeutic cargos, opening new avenues in the design of targeted theranostic probes for immune cells in the tumor microenvironment.

13.
BMC Pulm Med ; 21(1): 327, 2021 Oct 20.
Article in English | MEDLINE | ID: mdl-34670551

ABSTRACT

BACKGROUND: Detection of small peripheral lung nodules is constantly increasing with the development of low dose computed tomography lung cancer screening programs. A tissue diagnosis is often required to confirm malignity, with endobronchial biopsies being associated with a lower pneumothorax rate than percutaneous approaches. Endoscopic diagnosis of peripheral small size lung nodules is however often challenging using traditional bronchoscopy and endobronchial ultrasound alone. New virtual bronchoscopic navigation techniques such as electromagnetic navigational bronchoscopy (ENB) have developed to improve peripheral navigation, with diagnostic yield however remaining in the 30-50% range for small lesions. Recent studies have shown the benefits of combining Cone beam computed tomography (CBCT) with ENB to improve diagnostic yield to up to 83%. The use of ENB however remains limited by disposable cost, bronchus sign dependency and inaccuracies due to CT to body divergence. CASE PRESENTATION: This case report highlights the feasibility and usefulness of CBCT-guided bronchoscopy for the sampling of lung nodules difficult to reach through traditional bronchoscopy because of nodule size and peripheral position. Procedure was scheduled in a mobile robotic hybrid operating room with patient under general anaesthesia. CBCT acquisition was performed to localize the target lesion and plan the best path to reach it into bronchial tree. A dedicated software was used to segment the lesion and the bronchial path which 3D outlines were automatically fused in real time on the fluoroscopic images to augment live guidance. Navigation to the lesion was guided with bronchoscopy and augmented fluoroscopy alone. Before the sampling, CBCT imaging was repeated to confirm the proper position of the instrument into the lesion. Four transbronchial needle aspirations (TBNA) were performed and the tissue analysis showed a primary lung adenocarcinoma. CONCLUSIONS: CBCT and augmented fluoroscopy technique is a safe and effective and has potential to improve early stage peripheral lesions endobronchial diagnostic yield without ENB. Additional studies are warranted to confirm its safety, efficacy and technical benefits, both for diagnosis of oncological and non-oncological disease and for endobronchial treatment of inoperable patients.


Subject(s)
Cone-Beam Computed Tomography/methods , Fluoroscopy/methods , Lung Neoplasms/diagnostic imaging , Adenocarcinoma of Lung/diagnostic imaging , Adenocarcinoma of Lung/pathology , Aged , Humans , Image Processing, Computer-Assisted , Lung Neoplasms/pathology , Male
14.
J Radiol Prot ; 41(4)2021 Sep 30.
Article in English | MEDLINE | ID: mdl-33827064

ABSTRACT

The 2013/59/Euratom Directive reduced the occupational exposure limits for the lens. Since it has become crucial to estimate the dose absorbed by the lens, we have studied the individual variability of exposed workers' ocular conformations with respect to the data estimated from their personal dosimetry. The anterior eye conformations of 45 exposed workers were acquired using Scheimpflug imaging and classified according to their sight conditions (emmetropia, myopia or hypermetropia). Three eye models were computed, with two lens reconstructions, and implemented in an interventional radiology scenario using Monte Carlo code. The models were dosimetrically analysed by simulating setup A, a theoretical monoenergetic and isotropic photon source (10-150 keV) and setup B, a more realistic interventional setting with an angiographic x-ray unit (50, 75, 100 kV peak). Scheimpflug imaging provided an average anterior chamber depth of (6.4 ± 0.5) mm and a lens depth of (3.9 ± 0.3) mm, together with a reconstructed equatorial lens length of (7.1-10.1) mm. Using these data for model reconstruction, dose coefficients (DCs) were simulated for all ocular structures. Regardless of the eye model used, the DCs showed a similar trend with radiation energy, which highlighted that for the same energy and setup, no significant dependence on ocular morphology and workers' visual conditions was observed. The maximum difference obtained did not exceed 1% for all eye models or structures analysed. Therefore, the individual variabilities of worker ocular anatomy do not require any additional correction, compared to the personal dosimetry data measured with a dedicated lens dosimeter. To estimate the dose absorbed by the other eye structures, it is, instead, essential to know the spectrum of the source that has generated the irradiation, since there are differences between monoenergetic sources and more realistic angiographic units.


Subject(s)
Lens, Crystalline , Occupational Exposure , Humans , Monte Carlo Method , Occupational Exposure/analysis , Radiation Dosage , Radiation Dosimeters , Radiology, Interventional
15.
Sci Rep ; 10(1): 21693, 2020 12 10.
Article in English | MEDLINE | ID: mdl-33303795

ABSTRACT

The current framework of radiological protection of occupational exposed medical workers reduced the eye-lens equivalent dose limit from 150 to 20 mSv per year requiring an accurate dosimetric evaluation and an increase understanding of radiation induced effects on Lens cells considering the typical scenario of occupational exposed medical operators. Indeed, it is widely accepted that genomic damage of Lens epithelial cells (LEC) is a key mechanism of cataractogenesis. However, the relationship between apoptosis and cataractogenesis is still controversial. In this study biological and physical data are combined to improve the understanding of radiation induced effects on LEC. To characterize the occupational exposure of medical workers during angiographic procedures an INNOVA 4100 (General Electric Healthcare) equipment was used (scenario A). Additional experiments were conducted using a research tube (scenario B). For both scenarios, the frequencies of binucleated cells, micronuclei, p21-positive cells were assessed with different doses and dose rates. A Monte-Carlo study was conducted using a model for the photon generation with the X-ray tubes and with the Petri dishes considering the two different scenarios (A and B) to reproduce the experimental conditions and validate the irradiation setups to the cells. The simulation results have been tallied using the Monte Carlo code MCNP6. The spectral characteristics of the different X-ray beams have been estimated. All irradiated samples showed frequencies of micronuclei and p21-positive cells higher than the unirradiated controls. Differences in frequencies increased with the delivered dose measured with Gafchromic films XR-RV3. The spectrum incident on eye lens and Petri, as estimated with MCNP6, was in good agreement in the scenario A (confirming the experimental setup), while the mean energy spectrum was higher in the scenario B. Nevertheless, the response of LEC seemed mainly related to the measured absorbed dose. No effects on viability were detected. Our results support the hypothesis that apoptosis is not responsible for cataract induced by low doses of X-ray (i.e. 25 mGy) while the induction of transient p21 may interfere with the disassembly of the nuclear envelop in differentiating LEC, leading to cataract formation. Further studies are needed to better clarify the relationship we suggested between DNA damage, transient p21 induction and the inability of LEC enucleation.


Subject(s)
Cataract/etiology , DNA Damage/radiation effects , Epithelial Cells/pathology , Epithelial Cells/radiation effects , Lens, Crystalline/cytology , Lens, Crystalline/radiation effects , Occupational Exposure/adverse effects , Radiation Dosage , X-Rays/adverse effects , Cells, Cultured , Humans , Monte Carlo Method
16.
Oncotarget ; 11(44): 3972-3983, 2020 Nov 03.
Article in English | MEDLINE | ID: mdl-33216834

ABSTRACT

There is a growing interest in the antibody-based delivery of cytokines to the tumor environment as a means to boost the anti-cancer activity of tumor-resident T cells and NK cells. Here, we describe the expression and characterization of fusion proteins, featuring the L19 antibody (specific to the alternatively-spliced EDB domain of fibronectin) and an engineered cytokine with interleukin-2 and interleukin-15 properties. The cytokine moiety was fused either at the N-terminal or at the C-terminal extremity and both fusion proteins showed a selective tumor accumulation in a quantitative biodistribution experiment. The N-terminal fusion inhibited tumor growth in immunocompetent mice bearing F9 carcinomas or WEHI-164 sarcomas when used as single agent. The anticancer activity was compared to the one of the same cytokine payload used as recombinant protein or fused to an anti-hen egg lysozyme antibody, serving as negative control of irrelevant specificity in the mouse. These results indicate that the antibody-based delivery of engineered cytokines to the tumor neovasculature may mediate a potent anticancer activity.

17.
Comput Methods Programs Biomed ; 185: 105153, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31678792

ABSTRACT

BACKGROUND AND OBJECTIVES: Malignant lymphomas are cancers of the immune system and are characterized by enlarged lymph nodes that typically spread across many different sites. Many different histological subtypes exist, whose diagnosis is typically based on sampling (biopsy) of a single tumor site, whereas total body examinations with computed tomography and positron emission tomography, though not diagnostic, are able to provide a comprehensive picture of the patient. In this work, we exploit a data-driven approach based on multiple-instance learning algorithms and texture analysis features extracted from positron emission tomography, to predict differential diagnosis of the main malignant lymphomas subtypes. METHODS: We exploit a multiple-instance learning setting where support vector machines and random forests are used as classifiers both at the level of single VOIs (instances) and at the level of patients (bags). We present results on two datasets comprising patients that suffer from four different types of malignant lymphomas, namely diffuse large B cell lymphoma, follicular lymphoma, Hodgkin's lymphoma, and mantle cell lymphoma. RESULTS: Despite the complexity of the task, experimental results show that, with sufficient data samples, some cancer subtypes, such as the Hodgkin's lymphoma, can be identified from texture information: in particular, we achieve a 97.0% of sensitivity (recall) and a 94.1% of predictive positive value (precision) on a dataset that consists in 60 patients. CONCLUSIONS: The presented study indicates that texture analysis features extracted from positron emission tomography, combined with multiple-instance machine learning algorithms, can be discriminating for different malignant lymphomas subtypes.


Subject(s)
Lymphoma/classification , Machine Learning , Algorithms , Datasets as Topic , Humans , Lymphoma/diagnostic imaging , Positron-Emission Tomography/methods , Sensitivity and Specificity , Support Vector Machine , Tomography, X-Ray Computed/methods
18.
N Biotechnol ; 56: 38-45, 2020 May 25.
Article in English | MEDLINE | ID: mdl-31731038

ABSTRACT

Wheat bran could be utilised as feedstock for innovative and sustainable biorefinery processes. Here, an enzymatic hydrolysis process for ferulic acid (FA) extraction was optimised step by step for total wheat bran (Tritello) and then also applied to the outer bran layer (Bran 1). Proteins, reducing sugars, total phenols and FA were quantified. The highest FA yields (0.82-1.05 g/kg bran) were obtained either by rehydrating the bran by autoclaving (Tritello) or by steam explosion (Bran 1) using a bran/water ratio of 1:20, followed by enzymatic pre-treatment with Alcalase and Termamyl, to remove protein and sugars, and a final enzymatic hydrolysis with Pentopan and feruloyl esterase to solubilise phenol. FA was recovered from the final digestate via solid phase extraction. A 40-fold scale-up was also performed and the release of compounds along all the process steps and at increasing incubation times was monitored. Results showed that FA was initially present at a minimum level while it was specifically released during the enzymatic treatment. In the final optimized process, the FA extraction yield was higher than that obtained with NaOH control hydrolysis while, in comparison with other FA enzymatic extraction methods, fewer process steps were required and no buffers, strong acid/alkali nor toxic compounds were used. Furthermore, the proposed process may be easily scaled-up, confirming the feasibility of wheat bran valorisation by biorefinery processes to obtain valuable compounds having several areas of potential industrial exploitation.


Subject(s)
Coumaric Acids/isolation & purification , Dietary Fiber/metabolism , Subtilisins/metabolism , alpha-Amylases/metabolism , Coumaric Acids/chemistry , Coumaric Acids/metabolism , Hydrolysis
19.
Phys Med Biol ; 64(9): 095002, 2019 04 23.
Article in English | MEDLINE | ID: mdl-30921779

ABSTRACT

The aim of the study is to use the well-known channelized Hotelling observer model (CHO) to characterize a recently installed angiography system (GE Discovery IGS 740) using sets of images of a contrast-detail phantom acquired with clinical protocols. A Leeds TO10 phantom was used. The phantom has 108 details: 12 diameters (size range: 0.25 mm-11 mm), each with nine contrasts (declared range: 0.012-0.930 at 70 kVp 1.00 with 1 mm Cu filtration). TO10 has been imaged between two 10 cm thick homogeneous solid water slabs. Two FOVs (32 cm and 20 cm) were used. Fluoroscopy images were taken using an abdominal protocol at two different frame rates (15 fps and 7.5 fps) and at two dose levels (low and normal); cineangiography images were acquired using an abdominal protocol at 15 fps at two dose levels (low and normal). A 40 Gabor channels CHO with internal noise was used. Human observers' studies were carried out to tune the internal noise parameter and to validate the model observer. Contrast-detail curves were obtained from the CHO output using a visibility threshold of 75% and fitted with Rose's model theory in order to characterize the angiography system. Wilcoxon rank-sum tests were performed to investigate possible differences among the different sets of images. The CHO can distinguish between the two dose levels (p -values < 0.002), while FOV and frame rate do not affect the contrast-detail curves significantly. It is important to note that the CHO does not find statistically significant differences between a fluoroscopy with FOV = 20 cm at normal dose level (17.6 mGy min-1) and a cineangiography with FOV = 32 cm low dose level (42.1 mGy min-1). This result can lead to a dose reduction of about 70% for our specific task (i.e. a static, disc shaped object at known location in homogeneous field). Given their stability in comparison to human observers, model observers provide an effective tool for image quality evaluation.


Subject(s)
Angiography/instrumentation , Image Processing, Computer-Assisted , Phantoms, Imaging , Humans , Observer Variation
20.
Eur Radiol ; 29(7): 3802-3811, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30737568

ABSTRACT

OBJECTIVES: Tomosynthesis (DBT) has proven to be more sensitive than digital mammography, but it requires longer reading time. We retrospectively compared accuracy and reading times of a simplified protocol with 1-cm-thick slabs versus a standard protocol of slabs + 1-mm-spaced planes, both integrated with synthetic 2D. METHODS: We randomly selected 894 DBTs (including 12 cancers) from the experimental arm of the RETomo trial. DBTs were read by two radiologists to estimate specificity. A second set of 24 cancers (8 also present in the first set) mixed within 276 negative DBTs was read by two radiologists. In total, 28 cancers with 64 readings were used to estimate sensitivity. Radiologists read with both protocols separated by a 3-month washout. Only women that were positive at the screening reading were assessed. Variance was estimated taking into account repeated measures. RESULTS: Sensitivity was 82.8% (53/64, 95% confidence interval (95% CI) 67.2-92.2) and 90.6% (95% CI 80.2-95.8) with simplified and standard protocols, respectively. In the random screening setting, specificity was 97.9% (1727/1764, 95% CI 97.1-98.5) and 96.3% (95% CI 95.3-97.1), respectively. Inter-reader agreement was 0.68 and 0.54 with simplified and standard protocols, respectively. Median reading times with simplified protocol were 20% to 30% shorter than with standard protocol. CONCLUSIONS: A simplified protocol reduced reading time and false positives but may have a negative impact on sensitivity. KEY POINTS: • The adoption of digital breast tomosynthesis (DBT) in screening, more sensitive than mammography, could be limited by its potential effect on the radiologists' workload, i.e., increased reading time and fatigue. • A DBT simplified protocol with slab only, compared to a standard protocol (slab plus planes) both integrated with synthetic 2D, reduced time and false positives but had a negative impact on sensitivity.


Subject(s)
Breast Neoplasms/diagnosis , Carcinoma, Intraductal, Noninfiltrating/diagnosis , Early Detection of Cancer/methods , Mammography/methods , Mass Screening/methods , Aged , Female , Humans , Middle Aged , Reproducibility of Results , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...