Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Nanomaterials (Basel) ; 13(11)2023 May 25.
Article in English | MEDLINE | ID: mdl-37299631

ABSTRACT

The facile synthesis of biografted 2D derivatives complemented by a nuanced understanding of their properties are keystones for advancements in biosensing technologies. Herein, we thoroughly examine the feasibility of aminated graphene as a platform for the covalent conjugation of monoclonal antibodies towards human IgG immunoglobulins. Applying core-level spectroscopy methods, namely X-ray photoelectron and absorption spectroscopies, we delve into the chemistry and its effect on the electronic structure of the aminated graphene prior to and after the immobilization of monoclonal antibodies. Furthermore, the alterations in the morphology of the graphene layers upon the applied derivatization protocols are assessed by electron microscopy techniques. Chemiresistive biosensors composed of the aerosol-deposited layers of the aminated graphene with the conjugated antibodies are fabricated and tested, demonstrating a selective response towards IgM immunoglobulins with a limit of detection as low as 10 pg/mL. Taken together, these findings advance and outline graphene derivatives' application in biosensing as well as hint at the features of the alterations of graphene morphology and physics upon its functionalization and further covalent grafting by biomolecules.

2.
Commun Biol ; 5(1): 659, 2022 07 04.
Article in English | MEDLINE | ID: mdl-35787676

ABSTRACT

Oxidative stress is one of the key factors that leads to red blood cells (RBCs) aging, and impairs their biomechanics and oxygen delivery. It occurs during numerous pathological processes and causes anaemia, one of the most frequent side effects of cancer chemotherapy. Here, we used microfluidics to simulate the microcirculation of RBCs under oxidative stress induced by tert-Butyl hydroperoxide. Oxidative stress was expected to make RBCs more rigid, which would lead to decrease their transit velocity in microfluidic channels. However, single-cell tracking combined with cytological and AFM studies reveals cell heterogeneity, which increases with the level of oxidative stress. The data indicates that the built-in antioxidant defence system has a limit exceeding which haemoglobin oxidation, membrane, and cytoskeleton transformation occurs. It leads to cell swelling, increased stiffness and adhesion, resulting in a decrease in the transit velocity in microcapillaries. However, even at high levels of oxidative stress, there are persistent cells in the population with an undisturbed biophysical phenotype that retain the ability to move in microcapillaries. Developed microfluidic analysis can be used to determine RBCs' antioxidant capacity for the minimization of anaemia during cancer chemotherapy.


Subject(s)
Antioxidants , Neoplasms , Antioxidants/metabolism , Erythrocytes/metabolism , Humans , Neoplasms/metabolism , Oxidative Stress , tert-Butylhydroperoxide/metabolism , tert-Butylhydroperoxide/pharmacology
3.
Cells ; 10(12)2021 12 16.
Article in English | MEDLINE | ID: mdl-34944060

ABSTRACT

Microcirculation is one of the basic functional processes where the main gas exchange between red blood cells (RBCs) and surrounding tissues occurs. It is greatly influenced by the shape and deformability of RBCs, which can be affected by oxidative stress induced by different drugs and diseases leading to anemia. Here we investigated how in vitro microfluidic characterization of RBCs transit velocity in microcapillaries can indicate cells damage and its correlation with clinical hematological analysis. For this purpose, we compared an SU-8 mold with an Si-etched mold for fabrication of PDMS microfluidic devices and quantitatively figured out that oxidative stress induced by tert-Butyl hydroperoxide splits all RBCs into two subpopulations of normal and slow cells according to their transit velocity. Obtained results agree with the hematological analysis showing that such changes in RBCs velocities are due to violations of shape, volume, and increased heterogeneity of the cells. These data show that characterization of RBCs transport in microfluidic devices can directly reveal violations of microcirculation caused by oxidative stress. Therefore, it can be used for characterization of the ability of RBCs to move in microcapillaries, estimating possible side effects of cancer chemotherapy, and predicting the risk of anemia.


Subject(s)
Anemia/blood , Microcirculation/drug effects , Neoplasms/drug therapy , Oxidative Stress/drug effects , Anemia/chemically induced , Anemia/etiology , Anemia/pathology , Erythrocyte Count , Erythrocytes/drug effects , Erythrocytes/pathology , Humans , Hydrogen Peroxide/metabolism , Microfluidic Analytical Techniques , Neoplasms/blood , Neoplasms/complications , Oxidative Stress/genetics , tert-Butylhydroperoxide/pharmacology
4.
Mater Sci Eng C Mater Biol Appl ; 120: 111736, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33545879

ABSTRACT

There has been growing interest in recent years in developing multifunctional materials for studying the structure interface in biological systems. In this regard, the multimodal systems, which possess activity in the near-infrared (NIR) region, become even more critical for the possibility of improving examined biotissue depth and, eventually, data analysis. Herein, we engineered bi-modal contrast agents by integrating carbon nanotubes (CNT) and gold nanoparticles (AuNP) around silica microspheres using the Layer-by-Layer self-assembly method. The experimental studies revealed that microspheres with CNT sandwiched between AuNP exhibit strong absorption in the visible and NIR regions and high optoacoustic contrast (OA, also called photoacoustics) and Raman scattering when illuminated with 532 nm and 785 nm lasers, respectively. The developed microspheres demonstrated amplification of the signal in the OA flow cytometry at the laser wavelength of 1064 nm. This finding was further validated with ex vivo brain tissue using a portable Raman spectrometer and imaging with the Raster-scanning OA mesoscopy technique. The obtained data suggest that the developed contrast agents can be promising in applications of localization OA tomography (LOT), OA flow cytometry, and multiplex SERS detection.


Subject(s)
Metal Nanoparticles , Nanotubes, Carbon , Gold , Microspheres , Silicon Dioxide , Spectrum Analysis, Raman
5.
Sci Rep ; 10(1): 6902, 2020 Apr 23.
Article in English | MEDLINE | ID: mdl-32327708

ABSTRACT

In this paper we present a facile method for the synthesis of aminated graphene derivative through simultaneous reduction and amination of graphene oxide via two-step liquid phase treatment with hydrobromic acid and ammonia solution in mild conditions. The amination degree of the obtained aminated reduced graphene oxide is of about 4 at.%, whereas C/O ratio is up to 8.8 as determined by means of X-ray photoelectron spectroscopy. The chemical reactivity of the introduced amine groups is further verified by successful test covalent bonding of the obtained aminated graphene with 3-Chlorobenzoyl chloride. The morphological features and electronic properties, namely conductivity, valence band structure and work function are studied as well, illustrating the influence of amine groups on graphene structure and physical properties. Particularly, the increase of the electrical conductivity, reduction of the work function value and tendency to form wrinkled and corrugated graphene layers are observed in the aminated graphene derivative compared to the pristine reduced graphene oxide. As obtained aminated graphene could be used for photovoltaic, biosensing and catalysis application as well as a starting material for further chemical modifications.

6.
Sci Rep ; 8(1): 14154, 2018 Sep 20.
Article in English | MEDLINE | ID: mdl-30237450

ABSTRACT

This paper reports a facile and green method for conversion of graphene oxide (GO) into graphene by low-temperature heating (80 °C) in the presence of a glass wafer. Compared to conventional GO chemical reduction methods, the presented approach is easy-scalable, operationally simple, and based on the use of a non-toxic recyclable deoxygenation agent. The efficiency of the proposed method is further expanded by the fact that it can be applied for reducing both GO suspensions and large-scale thin films formed on various substrates prior to the reduction process. The quality of the obtained reduced graphene oxide (rGO) strongly depends on the type of the used glass wafer, and, particularly, magnesium silicate glass can provide rGO with the C/O ratio of 7.4 and conductivity of up to 33000 S*cm-1. Based on the data obtained, we have suggested a mechanism of the observed reduction process in terms of the hydrolysis of the glass wafer with subsequent interaction of the leached alkali and alkali earth cations and silicate anions with graphene oxide, resulting in elimination of the oxygen-containing groups from the latter one. The proposed approach can be efficiently used for low-cost bulk-quantity production of graphene and graphene-based materials for a wide field of applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...