Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Bone Miner Res ; 39(3): 271-286, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38477754

ABSTRACT

Data on bone microarchitecture in osteogenesis imperfecta (OI) are scarce. The aim of this cross-sectional study was to assess bone microarchitecture and strength in a large cohort of adults with OI using high-resolution peripheral quantitative computed tomography (HR-pQCT) and to evaluate challenges of using HR-pQCT in this cohort. Second-generation HR-pQCT scans were obtained at the distal radius and tibia in 118 men and women with Sillence OI type I, III, or IV using an extremity-length-dependent scan protocol. In total, 102 radius and 105 tibia scans of sufficient quality could be obtained, of which 11 radius scans (11%) and 14 tibia scans (13%) had a deviated axial scan angle as compared with axial angle data of 13 young women. In the scans without a deviated axial angle and compared with normative HR-pQCT data, Z-scores at the radius for trabecular bone mineral density (BMD), number, and separation were -1.6 ± 1.3, -2.5 ± 1.4, and -2.7 (IQR: 2.7), respectively. They were -1.4 ± 1.5 and -1.1 ± 1.2 for stiffness and failure load and between ±1 for trabecular thickness and cortical bone parameters. Z-scores were significantly lower for total and trabecular BMD, stiffness, failure load, and cortical area and thickness at the tibia. Additionally, local microarchitectural inhomogeneities were observed, most pronounced being trabecular void volumes. In the scans with a deviated axial angle, the proportion of Z-scores <-4 or >4 was significantly higher for trabecular BMD and separation (radius) or most total and trabecular bone parameters (tibia). To conclude, especially trabecular bone microarchitecture and bone strength were impaired in adults with OI. HR-pQCT may be used without challenges in most adults with OI, but approximately 12% of the scans may have a deviated axial angle in OI due to bone deformities or scan positioning limitations. Furthermore, standard HR-pQCT parameters may not always be reliable due to microarchitectural inhomogeneities nor fully reflect all inhomogeneities.


OI is a rare condition with large clinical heterogeneity. One of the major characteristics associated with OI is the increased fracture risk due to defects in bone structure and material. Data on the defects in bone structure at the micrometer level (i.e. bone microarchitecture) are scarce. Bone microarchitecture can be assessed noninvasively using HR-pQCT, but its use in OI has not extensively been described. Yet, potential challenges may arise related to among others the occurrence of short extremities and skeletal deformities in OI. We assessed bone microarchitecture and strength in 118 adults with OI types I, III, or IV using HR-pQCT with an extremity-length-dependent scan protocol. Additionally, we evaluated potential challenges of using HR-pQCT in this cohort. Our results demonstrated that predominantly trabecular microarchitecture­especially trabecular number and separation­and overall bone strength were impaired in adults with OI as compared with normative data. Furthermore, we observed various microarchitectural inhomogeneities, most pronounced being trabecular void volumes. Regarding applicability, HR-pQCT could be used without challenges in most adults with OI. However, deviations in scan region may potentially influence HR-pQCT parameters, and standard HR-pQCT analyses may not always give accurate results due to microarchitectural inhomogeneities nor fully reflect all microarchitectural inhomogeneities.


Subject(s)
Osteogenesis Imperfecta , Adult , Male , Humans , Female , Osteogenesis Imperfecta/diagnostic imaging , Cross-Sectional Studies , Bone Density , Bone and Bones/diagnostic imaging , Tibia/diagnostic imaging , Radius/diagnostic imaging , Upper Extremity , Absorptiometry, Photon
2.
Bone ; 182: 117066, 2024 May.
Article in English | MEDLINE | ID: mdl-38438097

ABSTRACT

BACKGROUND: The use of proton pump inhibitors (PPIs) has been associated with an increased fracture risk in observational studies. However, the reported association between PPI use and bone mineral density (BMD), bone microarchitecture, and bone strength is inconsistent. This study aims to assess the association between PPI use and bone microarchitecture and strength using high-resolution peripheral quantitative CT (HR-pQCT) in a three-year follow-up study in patients with a recent fracture visiting the Fracture Liaison Service (FLS). METHODS: This three-year prospective cohort study included FLS patients aged ≥ 50 years with a recent fracture (median age 62 [IQR 56-69] years, 68.7 % females) and without anti-osteoporosis treatment indication. HR-pQCT scans (distal radius and tibia) were obtained at baseline (T0) and three-year follow-up (T3). Volumetric bone mineral density and bone area, microarchitecture, and strength (micro-finite element analysis) were determined. The association between three-year continuous PPI use and the percentage change in HR-pQCT parameters between T0 and T3 was assessed using sex-stratified multivariate linear regression analyses. Covariates included age, BMI, vitamin-D deficiency (< 50 nmol/l), glucocorticoid use, and cardiovascular co-morbidity (males and females) fracture type (major/hip vs. all others, only males) and probable sarcopenia (only females). RESULTS: In total, 282 participants had available medication data throughout follow-up, of whom 20.6 % were continuous PPI users. In both males and females with complete HR-pQCT follow-up data (males: N = 69 radius, N = 84 tibia; females: N = 147 radius, N = 168 tibia), PPI use was not associated with the percentage change of any of the bone microarchitecture or strength parameters between T0 and T3 at the radius and tibia as compared to non-use. CONCLUSION: Compared to non-use, PPI use was not associated with the change of bone microarchitecture and strength in FLS patients at three years of follow-up. These results do not support that an altered bone microarchitecture or strength may contribute to the increased fracture risk associated with PPI use, as reported in observational studies.


Subject(s)
Fractures, Bone , Male , Female , Humans , Middle Aged , Follow-Up Studies , Prospective Studies , Fractures, Bone/diagnostic imaging , Bone Density , Bone and Bones , Tibia , Radius
3.
Bone ; 153: 116161, 2021 12.
Article in English | MEDLINE | ID: mdl-34455117

ABSTRACT

Improving the clinical outcome of scaphoid fractures may benefit from adequate monitoring of their healing in order to for example identify complications such as scaphoid nonunion at an early stage and to adjust the treatment strategy accordingly. However, quantitative assessment of the healing process is limited with current imaging modalities. In this study, high-resolution peripheral quantitative computed tomography (HR-pQCT) was used for the first time to assess the changes in bone density, microarchitecture, and strength during the healing of conservatively-treated scaphoid fractures. Thirteen patients with a scaphoid fracture (all confirmed on HR-pQCT and eleven on CT) received an HR-pQCT scan at baseline and three, six, twelve, and 26 weeks after first presentation at the emergency department. Bone mineral density (BMD) and trabecular microarchitecture of the scaphoid bone were quantified, and failure load (FL) was estimated using micro-finite element analysis. Longitudinal changes were evaluated with linear mixed-effects models. Data of two patients were excluded due to surgical intervention after the twelve-week follow-up visit. In the eleven fully evaluable patients, the fracture line became more apparent at 3 weeks. At 6 weeks, individual trabeculae at the fracture region became more difficult to identify and distinguish from neighboring trabeculae, and this phenomenon concerned a larger region around the fracture line at 12 weeks. Quantitative assessment showed that BMD and FL were significantly lower than baseline at all follow-up visits with the largest change from baseline at 6 weeks (-13.6% and - 23.7%, respectively). BMD remained unchanged thereafter, while FL increased. Trabecular thickness decreased significantly from baseline at three (-3.9%), six (-6.7%), and twelve (-4.4%) weeks and trabecular number at six (-4.5%), twelve (-7.3%), and 26 (-7.9%) weeks. Trabecular separation was significantly higher than baseline at six (+13.3%), twelve (+19.7%), and 26 (+16.3%) weeks. To conclude, this explorative HR-pQCT study showed a substantial decrease in scaphoid BMD, Tb.Th, and FL during the first 6 weeks of healing of conservatively-treated scaphoid fractures, followed by stabilization or increase in these parameters. At 26 weeks, BMD, trabecular microarchitecture, and FL were not returned to baseline values.


Subject(s)
Fractures, Bone , Scaphoid Bone , Bone Density , Finite Element Analysis , Fractures, Bone/diagnostic imaging , Fractures, Bone/therapy , Humans , Radius , Scaphoid Bone/diagnostic imaging , Tomography, X-Ray Computed
4.
J Bone Joint Surg Am ; 102(24): 2138-2145, 2020 Dec 16.
Article in English | MEDLINE | ID: mdl-33079896

ABSTRACT

BACKGROUND: Computed tomography (CT), magnetic resonance imaging, and bone scintigraphy are second-line imaging techniques that are frequently used for the evaluation of patients with a clinically suspected scaphoid fracture. However, as a result of varying diagnostic performance results, no true reference standard exists for scaphoid fracture diagnosis. We hypothesized that the use of high-resolution peripheral quantitative CT (HR-pQCT) in patients with a clinically suspected scaphoid fracture could improve scaphoid fracture detection compared with conventional CT in the clinical setting. METHODS: The present study included 91 consecutive patients (≥18 years of age) who presented to the emergency department with a clinically suspected scaphoid fracture between December 2017 and October 2018. All patients were clinically reassessed within 14 days after first presentation, followed by CT and HR-pQCT. If a scaphoid fracture was present, the fracture type was determined according to the Herbert classification system and correlation between CT and HR-pQCT was estimated with use of the Kendall W statistic or coefficient of concordance (W) (the closer to 1, the higher the correlation). RESULTS: The cohort included 45 men and 46 women with a median age of 52 years (interquartile range, 29 to 67 years). HR-pQCT revealed a scaphoid fracture in 24 patients (26%), whereas CT revealed a scaphoid fracture in 15 patients (16%). Patients with a scaphoid fracture were younger and more often male. The correlation between CT and HR-pQCT was high for scaphoid fracture type according to the Herbert classification system (W = 0.793; 95% confidence interval [CI], 0.57 to 0.91; p < 0.001) and very high for scaphoid fracture location (W = 0.955; 95%, CI 0.90 to 0.98; p < 0.001). CONCLUSIONS: In the present study, the number of patients diagnosed with a scaphoid fracture was 60% higher when using HR-pQCT as compared with CT. These findings imply that a substantial proportion of fractures-in this study, more than one-third-will be missed by the current application of CT scanning in patients with a clinically suspected scaphoid fracture. LEVEL OF EVIDENCE: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Fractures, Bone/diagnostic imaging , Scaphoid Bone/injuries , Tomography, X-Ray Computed/methods , Adult , Aged , Female , Humans , Male , Middle Aged , Scaphoid Bone/diagnostic imaging , Sensitivity and Specificity
5.
J Clin Densitom ; 23(3): 432-442, 2020.
Article in English | MEDLINE | ID: mdl-31495579

ABSTRACT

INTRODUCTION: Diagnosing scaphoid fractures remains challenging. High-resolution peripheral quantitative computed tomography (HR-pQCT) might be a potential imaging technique, but no data are available on its feasibility to scan the scaphoid bone in vivo. METHODOLOGY: Patients (≥18 years) with a clinically suspected scaphoid fracture received an HR-pQCT scan of the scaphoid bone (three 10.2-mm stacks, 61-µm voxel size) with their wrist immobilized with a cast. Scan quality assessment and bone contouring were performed using methods originally developed for HR-pQCT scans of radius and tibia. The contouring algorithm was applied on coarse hand-drawn pre-contours of the scaphoid bone, and the resulting contours (AUTO) were manually corrected (sAUTO) when visually deviating from bone margins. Standard morphologic analyses were performed on the AUTO- and sAUTO-contoured bones. RESULTS: Ninety-one patients were scanned. Two out of the first five scans were repeated due to poor scan quality (40%) based on standard quality assessment during scanning, which decreased to three out of the next 86 scans (3.5%) when using an additional thumb cast. Nevertheless, after excluding one scan with an incompletely scanned scaphoid bone, post hoc grading revealed a poor quality in 14.9% of the stacks and 32.9% of the scans in the remaining 85 patients. After excluding two scans with contouring problems due to scan quality, bone indices obtained by AUTO- and sAUTO-contouring were compared in 83 scans. All AUTO-contours were manually corrected, resulting in significant but small differences in densitometric and trabecular indices (<1.0%). CONCLUSIONS: In vivo HR-pQCT scanning of the scaphoid bone is feasible in patients with a clinically suspected scaphoid fracture when using a cast with thumb part. The proportion of poor-quality stacks is similar to radius scans, and AUTO-contouring appears appropriate in good- and poor-quality scans . Thus, HR-pQCT may be promising for diagnosis of and microarchitectural evaluations in suspected scaphoid fractures.


Subject(s)
Casts, Surgical , Fractures, Bone/diagnostic imaging , Scaphoid Bone/diagnostic imaging , Wrist Injuries/diagnostic imaging , Adult , Aged , Feasibility Studies , Female , Fractures, Bone/therapy , Humans , Image Processing, Computer-Assisted/methods , Logistic Models , Male , Middle Aged , Scaphoid Bone/injuries , Tomography, X-Ray Computed/methods , Wrist Injuries/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...