Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 17(9)2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38730902

ABSTRACT

This study experimentally investigates the influence of metal chips and glass fibers on the mode I fracture toughness, energy absorption, and tensile strength of polymer concretes (PCs) manufactured by waste aggregates. A substantial portion of the materials employed in manufacturing and enhancing the tested polymer concrete are sourced from waste material. To achieve this, semi-circular bend (SCB) samples were fabricated, both with and without a central crack, to analyze the strength and fracture behavior of the composite specimens. The specimens incorporated varying weight percentages comprising 50 wt% coarse mineral aggregate, 25 wt% fine mineral aggregate, and 25 wt% epoxy resin. Metal chips and glass fibers were introduced at 2, 4, and 8 wt% of the PC material to enhance its mechanical response. Subsequently, the specimens underwent 3-point bending tests to obtain tensile strength, mode I fracture toughness, and energy absorption up to failure. The findings revealed that adding 4% brass chips along with 4% glass fibers significantly enhanced energy absorption (by a factor of 3.8). However, using 4% glass fibers alone improved it even more (by a factor of 10.5). According to the results, glass fibers have a greater impact than brass chips. Introducing 8% glass fibers enhanced the fracture energy by 92%. However, in unfilled samples, aggregate fracture and separation hindered crack propagation, and filled samples presented added barriers, resulting in multiple-site cracking.

2.
Materials (Basel) ; 16(5)2023 Feb 22.
Article in English | MEDLINE | ID: mdl-36902925

ABSTRACT

In this study, the effect of through-the-thickness delamination plane position on the R-curve behavior of end-notch-flexure (ENF) specimens was investigated using experimental and numerical procedures. From the experimental point of view, plain-woven E-glass/epoxy ENF specimens with two different delamination planes, i.e., [012//012] and [017//07], were manufactured by hand lay-up method. Afterward, fracture tests were conducted on the specimens by aiding ASTM standards. The main three parameters of R-curves, including the initiation and propagation of mode II interlaminar fracture toughness and the fracture process zone length, were analyzed. The experimental results revealed that changing the delamination position in ENF specimen has a negligible effect on the initiation and steady steady-state toughness values of delamination. In the numerical part, the virtual crack closure technique (VCCT) was used in order to analyze the imitation delamination toughness as well as the contribution of another mode on the obtained delamination toughness. The numerical results indicated that by choosing an appropriate value of cohesive parameters, the trilinear cohesive zone model (CZM) is capable of predicting the initiation as well as propagation of the ENF specimens. Finally, the damage mechanisms at the delaminated interface were investigated with microscopic images taken using a scanning electron microscope.

3.
Implant Dent ; 25(2): 238-46, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26914543

ABSTRACT

INTRODUCTION: The aim of this in vitro study was to evaluate the effect of the type and design of the impression copings on the accuracy of implant impressions in 2 different conditions. MATERIALS AND METHODS: A reference model with 2 implants inserted in bilateral mandibular canines was fabricated. The posterior teeth were inserted as tilted to simulate intra-oral undercuts. The teeth were eliminated to create an edentulous condition. Three different impression techniques were performed (open high retentive [OH], open low retentive [OL], closed [C]) for each condition. Total of 48 casts were made. Two scan-bodies were secured on each cast, scanned by an optical scanner. Then, they were compared to the scan of the reference model, and the calculated mean errors were analyzed with a 2-way ANOVA and Tukey test. RESULTS: There was no significant difference between the complete and partially edentulous groups (F = 3.252, P = 0.079). There was significant difference between the different designs of the impression copings (F = 31.789, P < 0.001) but the interaction between the dependent variables was not significant (F = 0.511, P = 0.603). CONCLUSIONS: The design of the impression copings was more important than the undercuts. The accuracy of the closed tray coping was greater than the low retentive coping and equal to the high retentive coping.


Subject(s)
Dental Impression Technique , Dental Prosthesis Design/methods , Dental Prosthesis , Cuspid , Dental Impression Technique/standards , Dental Prosthesis/standards , Dental Prosthesis Design/standards , In Vitro Techniques , Optical Imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...